Fantech ERV FIT 120E-D-EC-M-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 120E-D-EC-M-HC
129 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 129 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
77%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 17 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts129 cfm

$22.45

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

23W
Running continuously
201kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

ECMEC motors: 2.2 cfm/W instead of 0.9

The -EC suffix replaces the AC motors with electronically commutated motors. Fantech's selection guide lists 2.2 cfm/W fan efficacy at 0 °C, versus 0.9 for the FIT 120E-D, and a 40 to 129 cfm range at 0.4 in. Every -EC version also includes the -D motorized damper.

-M-HCMirrored and cordless in one unit

The FIT 120E-D-EC-M-HC combines two options of the FIT 120E-D-EC: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005122Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−17 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 129 cfm.

23 WMeasured at the airflow it actually runs at

Its 77% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005122) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
35 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
129 cfm
SRE at 0 °C (51 cfm)
77%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
80%
Power draw
23 W
Efficacy
2.2 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2005122
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005122). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The most complete FIT: four options on a single unit

The Fantech FIT 120E-D-EC-M-HC is the only version in the series that combines every option. Read from left to right, its name gives the 120 size (about 120 cfm at 0.4 in.), energy recovery (E), the motorized damper (D), electronically commutated motors (EC), the mirror configuration (M) and the permanent electrical connection (HC). This energy recovery ventilator (ERV) offers a certified net airflow of 129 cfm at 0.4 in.

It is aimed at a specific case: a unit with a reversed floor plan, connected to a furnace, in a project that requires fixed wiring and low consumption.

What each option brings

EC motors

23 W at the 51 cfm test airflow, versus 55 W for the FIT 120E-D-M-HC, its AC motor equivalent. Fan efficiency rises to 2.2 cfm/W, and the annual estimate in the spec sheet above drops to 201 kWh.

Motorized damper

It closes when the air exchanger is stopped, so that the furnace blower does not draw untreated outdoor air through the return plenum.

Mirror configuration

The home's supply and return air are on the left rather than the right. The installation diagrams are read in reverse.

Permanent connection

No cord: the circuit wires come in through a 3/8 in. cable clamp and connect to the unit's wires and grounding screw.

Performance according to the HVI directory

  • Sensible recovery efficiency at 0 °C: 77% at 51 cfm, 80% adjusted.
  • At −25 °C: 61% at 51 cfm. Section 9.32 of the Code sets the minimum at 54% for Greater Montreal.
  • Total recovery at 35 °C: 70%, according to Fantech.
  • Airflow range: 40 to 129 cfm; 74 W at high speed.

EC or AC: the difference in numbers

Specification FIT 120E-D-EC-M-HC FIT 120E-D-M-HC
Net airflow at 0.4 in. 129 cfm 127 cfm
Power at the test airflow 23 W 55 W
Fan efficiency 2.2 cfm/W 0.9 cfm/W
Sensible recovery at 0 °C 77% 74%
Annual estimate 201 kWh 482 kWh

The airflow gap is slim; the consumption gap is not. On a unit that ventilates almost non-stop, it is the kilowatt-hour line that will make the difference over the years.

Footprint and installation

The unit measures 23.16 × 20.75 × 10.06 in. and weighs 35 lb. With the damper, its overall width is 25 in. It connects on the sides through four round 5 in. ports and needs no drain. Allow 8 1/2 in. in front of the door and 2 3/8 in. above the electrical box. The furnace blower must run when the ERV is ventilating: continuously, or interlocked through the NO, C and NC terminals.

Commissioning

A unit with this many options is checked point by point. We verify the fixed wiring, the wiring diagram specific to the EC mirror version, the operation of the damper and the furnace interlock. At start-up, the exhaust runs alone for ten seconds. We then go through the MIN, AUTO and MAX positions, then balance stale air and fresh air with a Fantech touchscreen control and a manometer, in 1% steps.

Maintenance schedule

  • Filters: every three months, or sooner if they are dirty.
  • Core: every six months.
  • Inside of the unit, exterior hoods and ducts: once a year.
  • General check-up by a qualified contractor: once a year.

Filters and core

Two electrostatic, washable 11 5/16 × 8 1/8 in. MERV 3 filters are supplied; MERV 8 (461674) and MERV 13 (461675) filters are sold as options. The membrane core tolerates freezing, can be washed with water and resists mould, according to Fantech.

Warranty

EC motors covered for 7 years; core, electrical components and damper motor covered for 5 years. These motors and the damper motor are also available as replacement parts.

Installation by AirGreen in Greater Montreal

AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore. The room-by-room ventilation calculation under CSA F326 confirms that a 120 size and each of the options are really needed. We plan the circuit with the electrician, connect the unit to the furnace return and balance supply and exhaust to the calculated airflow, with the blower running.

In the HVI directory, the FIT 120E-D-EC-M-HC is certified in Section III (no. 2005122): anyone can check its airflows and efficiencies there. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already open under the program's transition rules.

Free quote: 514 316-2973 or sales@airgreen.ca.