Fantech ERV FIT 120E-D-EC-M Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 120E-D-EC-M
129 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 129 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 129 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
77%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 17 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts129 cfm

$22.45

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

23W
Running continuously
201kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

ECMEC motors: 2.2 cfm/W instead of 0.9

The -EC suffix replaces the AC motors with electronically commutated motors. Fantech's selection guide lists 2.2 cfm/W fan efficacy at 0 °C, versus 0.9 for the FIT 120E-D, and a 40 to 129 cfm range at 0.4 in. Every -EC version also includes the -D motorized damper.

-MMirrored version: dwelling-side ports on the left

On the FIT 120E-D-EC, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-D-EC-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005061Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−17 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 129 cfm.

23 WMeasured at the airflow it actually runs at

Its 77% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005061) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
35 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
129 cfm
SRE at 0 °C (51 cfm)
77%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
80%
Power draw
23 W
Efficacy
2.2 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2005061
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005061). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

EC motors and left-side connections, for mirror-image units

In a condo building, it is often the occupant who pays the electricity for the ERV, for years. The Fantech FIT 120E-D-EC-M addresses that concern with electronically commutated motors: 23 W at the 51 cfm test airflow, versus 55 W for the AC motor version. The “M” puts the home's supply and return air on the left side, for units built as the reverse of their neighbours.

This energy recovery ventilator delivers a net airflow of 129 cfm at 0.4 in. and includes the -D motorized damper, found on all EC versions.

Operating cost

The spec sheet above estimates annual consumption at 201 kWh, or about $22 per year, versus 482 kWh and $54 for a FIT 120E-D-M with AC motors. Fantech's selection guide gives 2.2 cfm/W, the best ratio in the FIT series. At high speed, consumption is 74 W. For a developer, these are simple figures to present to buyers.

The mirror configuration

On the FIT 120E-D-EC, the connections serving the home are on the right; on the -EC-M, they are on the left. Everything else is identical: same motors, same core, same damper. In a building of symmetrical units, we order both versions in proportion to the plan, so that each ventilator connects in a straight line. Fantech provides a wiring diagram specific to the EC mirror version, which we follow when wiring.

Recovery efficiency

Sensible recovery efficiency is 77% at 0 °C (51 cfm), 80% adjusted. At −25 °C, it stays at 61% at 51 cfm, above the 54% threshold required by section 9.32 of the Code in Greater Montreal. In summer, total recovery reaches 70% at 35 °C, which limits the humidity coming in.

The damper and the furnace

When the unit is connected to the return plenum, the damper closes when it stops: the blower can no longer draw untreated outdoor air through the ERV. The blower must run during ventilation, continuously or interlocked through the NO, C and NC terminals.

A control designed for occupants

For units that are sold or rented, the ECO-Feel Auto IAQ control avoids a lot of service calls. It measures VOCs, chooses the mode and speed itself according to the season, and offers no settings: everything is programmed at the factory. If the buyer wants to stay in control, the ECO-Touch Auto IAQ displays a maintenance reminder and keeps its settings after a power outage. Bathroom timers can be added for boost ventilation at high speed.

The core

The polymer membrane core transfers heat and humidity, tolerates freezing and resists mould. To wash it, rinse it with tap water through one inlet, then through the other, until the water runs out clear. It then dries for two to three hours before being put back in place, arrow pointing toward the motors.

Installation

  • Cabinet of 23.16 × 20.75 × 10.06 in., weighing 35 lb.
  • Width with the damper: 25 in.
  • Side connection, 5 in. ducts; no drain.
  • Ceiling or wall mounting, bracket included.
  • Power by cord, 120 V.
  • Clearances: 8 1/2 in. in front of the door to take out the core, 2 3/8 in. above the electrical box.
  • Fresh air intake at least 18 in. above the ground, away from dryer vents and gas meters.

Maintenance

Two electrostatic, washable MERV 3 filters (11 5/16 × 8 1/8 in.); MERV 8 (461674) and MERV 13 (461675) as options. Fantech calls for inspecting the filters every three months and the core every six months.

Warranty

Fantech warrants the motors for 7 years, and the core, the electrical components and the damper motor for 5 years. If an EC motor ever had to be replaced after the warranty, Fantech sells it as a replacement part, as it does the control board and the transformer.

AirGreen in Greater Montreal

We work for owners, developers and condo associations in Montreal, Laval, Longueuil, the North Shore and the South Shore. The room-by-room calculation under CSA F326 sets the airflow for each unit; we mount the ERV on the correct side, then balance it to the calculated airflow.

The FIT 120E-D-EC-M is certified in Section III of the HVI directory (no. 2005061): its airflows and efficiencies are published and verifiable by anyone. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already open under the program's transition rules.

For a free quote, reach us at 514 316-2973 or sales@airgreen.ca.