Fantech ERV FIT 120E-D-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 120E-D-HC
127 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
74%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts127 cfm

$53.68

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

55W
Running continuously
482kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-DBuilt-in motorized outdoor air damper

The -D suffix means the FIT 120E-D-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-HC.

-HCHard-connect version shipped without a cord

The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 120E-D-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005118Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.

55 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005118) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
35 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
127 cfm
SRE at 0 °C (51 cfm)
74%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
81%
Power draw
55 W
Efficacy
0.9 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2005118
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005118). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

For a home with a furnace, with a permanent power connection

The Fantech FIT 120E-D-HC combines the large FIT size, a motorized damper on the outdoor air and a power supply with no cord. It is the one to choose when the air exchanger will be connected to a furnace return and the code or the specifications call for a fixed connection to the circuit. Its net airflow is 127 cfm at 0.4 in., and 146 cfm at 0.2 in.

In renovation: the return-return method

In an existing home, it is often impossible to run dedicated ducts to every bedroom. Fantech then offers the simplified installation: the supply and exhaust of the ERV are both connected to the furnace return plenum, with stale air drawn from higher up on the plenum. This method also works when the bathroom and kitchen already have their own exhaust fans. The manufacturer then recommends a unit with a damper: that is the role of the -D.

It does not apply to a multi-zone system, or to a home with two forced-air systems. During ventilation, the blower must run: continuously, or started by the unit's NO, C, NC relay.

The hard-wired connection

Supplied without a cord, the unit takes the circuit wires through a 3/8 in. cable clamp fitted on the electrical box. They are connected to the unit's wires and grounding screw. A clearance of 2 3/8 in. above the box is enough for this work.

What it recovers

Sensible recovery efficiency is 74% at 0 °C and 51 cfm (81% adjusted), and 61% at −25 °C at the same airflow. The 54% threshold in section 9.32 of the Code for Greater Montreal is therefore met. In hot weather (35 °C), Fantech states 64% total recovery. At the test airflow, the motors draw 55 W.

Defrost works by stopping the supply fan: during the cycle, only stale air passes through the core. No drain is needed.

Cutting through the wall for the hoods

In a renovation, the two exterior hoods require two openings, or a single one with a tandem hood if regulations allow it. Fantech's manual details the installation: trace the openings from the hood collar, cut them slightly larger to let the insulation through, pull the insulated flexible duct until it is straight, fasten the inner liner to the collar, bring the insulation and vapour barrier back over it, then seal. The hoods are screwed to the wall and caulked all the way around. The fresh air intake stays at least 18 in. above the ground or the snow.

Dimensions and weight

  • 23.16 × 20.75 × 10.06 in.; 35 lb.
  • Width with the damper: 25 in. (24 5/8 in. without the damper).
  • Side connection, 5 in. ducts.
  • 8 1/2 in. in front of the door for access to the core.

A simple control

For an existing home, the EDF3 is often enough. It offers three modes: Econo, which ventilates continuously at low or medium speed; 20 minutes per hour, which runs the unit at high speed and then pauses it for 40 minutes; and continuous, at high speed. The speeds depend on the jumpers set by the installer.

Maintenance

Two washable electrostatic MERV 3 filters, 11 5/16 × 8 1/8 in. size; MERV 8 (461674) and MERV 13 (461675) as options. Filters to be inspected every three months, the core every six months. Once a year, Fantech recommends vacuuming the inside of the unit and clearing debris from the exterior hoods and the ducts. If the unit is mounted on the ceiling, hold the core and filters when you open the door: they can fall out.

Warranty

7 years for the motors; 5 years for the core, the electrical components and the damper motor.

Installation by AirGreen in Montreal and the suburbs

Our team travels throughout Montreal, Laval and Longueuil, as well as the North Shore and the South Shore. The ventilation airflow is calculated room by room under the CSA F326 standard. We then choose how to connect to the furnace, coordinate the circuit with the electrician and balance the unit to the calculated airflow with the blower running.

In the HVI directory, the FIT 120E-D-HC is certified in Section III (no. 2005118): anyone can check its airflows and efficiencies there. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already open under the program's transition rules.

Call us at 514 316-2973 or write to sales@airgreen.ca for a free quote.