Fantech ERV FIT 120E-D-M-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 120E-D-M-HC
127 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
74%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts127 cfm

$53.68

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

55W
Running continuously
482kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-DBuilt-in motorized outdoor air damper

The -D suffix means the FIT 120E-D-M-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-M-HC.

-M-HCMirrored and cordless in one unit

The FIT 120E-D-M-HC combines two options of the FIT 120E-D: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005121Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.

55 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005121) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
35 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
127 cfm
SRE at 0 °C (51 cfm)
74%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
81%
Power draw
55 W
Efficacy
0.9 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
35 lb
Power supply
120 V
HVI certification (Section III)
2005121
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005121). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

The fully equipped FIT 120

The Fantech FIT 120E-D-M-HC carries every option of the large FIT size with AC motors: motorized damper, mirror configuration and permanent electrical connection. This energy recovery ventilator (ERV) is aimed at large units with a reversed floor plan, connected to a furnace, in projects where the code requires a fixed connection. Its certified net airflow is 127 cfm at 0.4 in.

What each suffix changes

Suffix Effect Who it is for
-D Motorized damper on the outdoor air, closed when the unit is off Unit connected to a furnace return
-M Home supply and return on the left Units built as mirror images
-HC Supplied without a cord, wired to the circuit Codes or specifications requiring a permanent connection

The only suffix missing is -EC. If you also want electronically commutated motors, the FIT 120E-D-EC-M-HC brings all four options together.

An ERV rather than an HRV

An HRV recovers heat from the stale air, but not its humidity. An ERV like this one also passes part of the water vapour through the membrane of its core. In a recent, airtight home, this helps keep the air less dry in January, and keep part of July's humidity outside. The core produces no condensate to drain: no drain is required.

Performance

The HVI directory gives 74% sensible recovery efficiency at 0 °C (51 cfm) and 81% as an adjusted value. At −25 °C, the unit holds 61% at 51 cfm; section 9.32 of the Code requires 54% in Greater Montreal. For summer, Fantech lists a total recovery of 64% at 35 °C.

Electrical

AC motors: 55 W at the test airflow, 0.9 cfm/W, up to 104 W at high speed. Annual estimate in the spec sheet: 482 kWh. The connection is made through a 3/8 in. cable clamp, to the unit's wires and grounding screw.

Installation

  • Cabinet of 23.16 × 20.75 × 10.06 in., 35 lb, 25 in. wide with the damper.
  • Round 5 in. side connections; no drain.
  • Ceiling or wall mounting; the long bracket and the two angle brackets are included.
  • Furnace blower interlocked through the NO, C and NC terminals, or running continuously.
  • Access: 8 1/2 in. of clearance in front of the door for the core; 2 3/8 in. of clearance above the box for the wiring.

Ceiling or wall mounting

The unit hangs from a long bracket and two angle brackets, screwed into the joists or studs. On the ceiling, the unit is slid horizontally onto the long bracket all the way to the end of the slot, while holding it so the electrical box is not damaged; the two brackets are then flush. On the wall, the angle bracket extends past the long bracket, and two sheet metal screws keep the unit from falling. In a large home, we choose the position based on access: you must be able to open the door and take out the core without taking down a ceiling.

Commissioning

We follow Fantech's checklist before the first start-up: no debris in the unit or in the ducts, ducts insulated according to the rules, accessories properly installed. When powered up, the unit first runs ten seconds of exhaust only. We then check the MIN, AUTO and MAX positions, then balance exhaust and supply with the blower running. The signed report shows the measured pressure and both airflows.

Parts and maintenance

Filters: two washable electrostatic MERV 3, 11 5/16 × 8 1/8 in., with MERV 8 (461674) and MERV 13 (461675) as options. The membrane core is rinsed with tap water and dries in two to three hours. Fantech sells the damper motor, the fan motors, the control board, the core and the door as replacement parts.

Warranty

Motors 7 years; core, electrical components and damper motor 5 years.

Installation by AirGreen in Greater Montreal

We install this model in Montreal, Laval, Longueuil, and on the North Shore as well as the South Shore. The room-by-room calculation under CSA F326 first confirms the size. We then check the orientation on the plan, coordinate the circuit with the electrician, connect the ERV to the furnace return and balance both fans to the calculated airflow.

The FIT 120E-D-M-HC is listed in Section III of the HVI directory under no. 2005121, which makes its airflows and efficiencies verifiable by anyone. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already open under the program's transition rules.