Échangeur d'Air Fantech ERV FIT 120E-D-M-HC | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D-M-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-M-HC.
-M-HCMirrored and cordless in one unit
The FIT 120E-D-M-HC combines two options of the FIT 120E-D: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005121Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm. Most spec sheets show only the first number, precisely because it looks better.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005121. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005121
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005121). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
La version complète du FIT 120
Le Fantech FIT 120E-D-M-HC porte toutes les options du grand format FIT à moteurs AC : volet motorisé, configuration miroir et raccordement électrique permanent. Ce ventilateur récupérateur d'énergie (VRE) vise les grands logements en plan inversé, reliés à une fournaise, dans les projets où le code exige un branchement fixe. Son débit net homologué est de 127 pcm à 0,4 po.
Ce que change chaque suffixe
| Suffixe | Effet | Pour qui |
|---|---|---|
| -D | Volet motorisé sur l'air extérieur, fermé à l'arrêt | Appareil raccordé au retour d'une fournaise |
| -M | Alimentation et retour du logement à gauche | Logements construits en miroir |
| -HC | Livré sans cordon, raccordé au circuit | Codes ou devis exigeant un raccordement permanent |
Le seul suffixe absent est -EC. Si vous voulez aussi les moteurs à commutation électronique, le FIT 120E-D-EC-M-HC réunit les quatre options.
Un VRE plutôt qu'un VRC
Un VRC récupère la chaleur de l'air vicié, mais pas son humidité. Un VRE comme celui-ci fait passer aussi une partie de la vapeur d'eau à travers la membrane de son noyau. Dans un logement récent et étanche, cela aide à garder l'air moins sec en janvier, et à laisser dehors une part de l'humidité de juillet. Le noyau ne produit pas de condensat à évacuer : aucun drain n'est requis.
Rendement
Le répertoire HVI donne 74 % d'efficacité de récupération sensible à 0 °C (51 pcm) et 81 % en valeur ajustée. À −25 °C, l'appareil conserve 61 % à 51 pcm; la section 9.32 du Code en exige 54 % dans le Grand Montréal. Pour l'été, Fantech indique une récupération totale de 64 % à 35 °C.
Électricité
Moteurs à courant alternatif : 55 W au débit d'essai, 0,9 pcm/W, jusqu'à 104 W en haute vitesse. Estimation annuelle de la fiche : 482 kWh. Le raccordement se fait par un serre-câble de 3/8 po, aux fils et à la vis de mise à la terre de l'appareil.
Installation
- Boîtier de 23,16 × 20,75 × 10,06 po, 35 lb, 25 po de largeur avec le volet.
- Raccords latéraux ronds de 5 po; pas de drain.
- Montage au plafond ou au mur; le support long et les deux équerres sont inclus.
- Soufflerie de la fournaise asservie par les bornes NO, C et NC, ou en marche continue.
- Accès : 8 1/2 po libres devant la porte pour le noyau; 2 3/8 po libres au-dessus du boîtier pour le câblage.
Montage au plafond ou au mur
L'appareil se suspend avec un support long et deux équerres, vissés dans les solives ou les montants. Au plafond, on glisse l'appareil à l'horizontale sur le support long jusqu'au fond de la fente, en le retenant pour ne pas abîmer le boîtier électrique; les deux supports sont alors à égalité. Au mur, l'équerre dépasse le support long, et deux vis à tôle empêchent l'appareil de tomber. Dans un grand logement, nous choisissons la position selon l'accès : il faut pouvoir ouvrir la porte et sortir le noyau sans démonter un plafond.
Mise en service
Nous suivons la liste de Fantech avant le premier démarrage : aucun débris dans l'appareil ni dans les conduits, conduits isolés selon les règles, accessoires bien posés. Sous tension, l'appareil fait d'abord dix secondes d'évacuation seule. Nous vérifions ensuite les positions MIN, AUTO et MAX, puis nous équilibrons l'évacuation et l'alimentation avec la soufflerie en marche. Le rapport signé indique la pression mesurée et les deux débits.
Pièces et entretien
Filtres : deux MERV 3 électrostatiques lavables de 11 5/16 × 8 1/8 po, avec MERV 8 (461674) et MERV 13 (461675) en option. Le noyau à membrane se rince à l'eau du robinet et sèche deux à trois heures. Fantech vend le moteur de volet, les moteurs de ventilateur, la carte de commande, le noyau et la porte comme pièces de rechange.
Garantie
Moteurs 7 ans; noyau, composants électriques et moteur du volet 5 ans.
Installation par AirGreen dans le Grand Montréal
Ce modèle, nous l'installons à Montréal, à Laval, à Longueuil, sur la Rive-Nord comme sur la Rive-Sud. Le calcul pièce par pièce selon CSA F326 confirme d'abord le format. Nous vérifions ensuite l'orientation sur le plan, coordonnons le circuit avec l'électricien, raccordons le VRE au retour de la fournaise et équilibrons les deux ventilateurs au débit calculé.
Le FIT 120E-D-M-HC figure à la section III du répertoire HVI (no 2005121). Il peut être admissible à l'aide Rénoclimat de 500 $ quand la cote ÉnerGuide s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux.
Soumission gratuite : 514 316-2973, sales@airgreen.ca.