Fantech ERV FIT 120E-D-M-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D-M-HC has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-M-HC.
-M-HCMirrored and cordless in one unit
The FIT 120E-D-M-HC combines two options of the FIT 120E-D: the dwelling-side ports move to the left (-M) and the unit ships with no cord for permanent wiring to the circuit (-HC). The combination suits mirror-image floor plans where code requires a fixed connection.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005121Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005121) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005121
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005121). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The fully equipped FIT 120
The Fantech FIT 120E-D-M-HC carries every option of the large FIT size with AC motors: motorized damper, mirror configuration and permanent electrical connection. This energy recovery ventilator (ERV) is aimed at large units with a reversed floor plan, connected to a furnace, in projects where the code requires a fixed connection. Its certified net airflow is 127 cfm at 0.4 in.
What each suffix changes
| Suffix | Effect | Who it is for |
|---|---|---|
| -D | Motorized damper on the outdoor air, closed when the unit is off | Unit connected to a furnace return |
| -M | Home supply and return on the left | Units built as mirror images |
| -HC | Supplied without a cord, wired to the circuit | Codes or specifications requiring a permanent connection |
The only suffix missing is -EC. If you also want electronically commutated motors, the FIT 120E-D-EC-M-HC brings all four options together.
An ERV rather than an HRV
An HRV recovers heat from the stale air, but not its humidity. An ERV like this one also passes part of the water vapour through the membrane of its core. In a recent, airtight home, this helps keep the air less dry in January, and keep part of July's humidity outside. The core produces no condensate to drain: no drain is required.
Performance
The HVI directory gives 74% sensible recovery efficiency at 0 °C (51 cfm) and 81% as an adjusted value. At −25 °C, the unit holds 61% at 51 cfm; section 9.32 of the Code requires 54% in Greater Montreal. For summer, Fantech lists a total recovery of 64% at 35 °C.
Electrical
AC motors: 55 W at the test airflow, 0.9 cfm/W, up to 104 W at high speed. Annual estimate in the spec sheet: 482 kWh. The connection is made through a 3/8 in. cable clamp, to the unit's wires and grounding screw.
Installation
- Cabinet of 23.16 × 20.75 × 10.06 in., 35 lb, 25 in. wide with the damper.
- Round 5 in. side connections; no drain.
- Ceiling or wall mounting; the long bracket and the two angle brackets are included.
- Furnace blower interlocked through the NO, C and NC terminals, or running continuously.
- Access: 8 1/2 in. of clearance in front of the door for the core; 2 3/8 in. of clearance above the box for the wiring.
Ceiling or wall mounting
The unit hangs from a long bracket and two angle brackets, screwed into the joists or studs. On the ceiling, the unit is slid horizontally onto the long bracket all the way to the end of the slot, while holding it so the electrical box is not damaged; the two brackets are then flush. On the wall, the angle bracket extends past the long bracket, and two sheet metal screws keep the unit from falling. In a large home, we choose the position based on access: you must be able to open the door and take out the core without taking down a ceiling.
Commissioning
We follow Fantech's checklist before the first start-up: no debris in the unit or in the ducts, ducts insulated according to the rules, accessories properly installed. When powered up, the unit first runs ten seconds of exhaust only. We then check the MIN, AUTO and MAX positions, then balance exhaust and supply with the blower running. The signed report shows the measured pressure and both airflows.
Parts and maintenance
Filters: two washable electrostatic MERV 3, 11 5/16 × 8 1/8 in., with MERV 8 (461674) and MERV 13 (461675) as options. The membrane core is rinsed with tap water and dries in two to three hours. Fantech sells the damper motor, the fan motors, the control board, the core and the door as replacement parts.
Warranty
Motors 7 years; core, electrical components and damper motor 5 years.
Installation by AirGreen in Greater Montreal
We install this model in Montreal, Laval, Longueuil, and on the North Shore as well as the South Shore. The room-by-room calculation under CSA F326 first confirms the size. We then check the orientation on the plan, coordinate the circuit with the electrician, connect the ERV to the furnace return and balance both fans to the calculated airflow.
The FIT 120E-D-M-HC is listed in Section III of the HVI directory under no. 2005121, which makes its airflows and efficiencies verifiable by anyone. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already open under the program's transition rules.