Échangeur d'Air Fantech ERV FIT 120E-D-M | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D-M has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-M.
-MMirrored version: dwelling-side ports on the left
On the FIT 120E-D, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-D-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005060Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm. Most spec sheets show only the first number, precisely because it looks better.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005060. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005060
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005060). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Pour les jumelés et maisons en rangée construits en miroir
Dans un jumelé ou une rangée de maisons de ville, une unité sur deux est souvent l'image inversée de sa voisine. Le Fantech FIT 120E-D-M est pensé pour ces plans : son alimentation et son retour d'air se raccordent du côté gauche, et il intègre un volet motorisé pour être relié au retour d'une fournaise. Avec un débit net de 127 pcm à 0,4 po (146 pcm à 0,2 po), c'est le grand format de la série FIT. Son boîtier ne fait que 10,06 po d'épaisseur, ce qui laisse de la place sous les solives d'un sous-sol.
Le raccordement à la fournaise
Avec une installation partiellement dédiée, l'air neuf de ce VRE entre dans le plénum de retour et la fournaise le tempère avant de le distribuer. L'air vicié est capté dans les pièces humides. Le volet se ferme quand l'appareil ne ventile pas, pour que la soufflerie n'aspire pas d'air extérieur froid à travers lui. Nous asservissons la soufflerie au relais NO, C, NC de l'appareil, ou nous la réglons en marche continue.
Les bouches d'évacuation se placent dans la salle de bain, la cuisine ou la salle de lavage, haut sur le mur ou au plafond.
L'orientation à gauche
Le côté des raccords détermine le tracé de tous les conduits. Avec la bonne version, on garde des conduits courts, avec des coudes à 45° et des raccords en Y comme le recommande Fantech, ce qui préserve le débit et limite le bruit. Les schémas du manuel s'appliquent en les inversant. Le schéma électrique de la version miroir est distinct, et nous le suivons à la lettre.
Rendement et consommation
Ce ventilateur récupérateur d'énergie affiche une efficacité de récupération sensible de 74 % à 0 °C (51 pcm) et de 81 % ajustée. À −25 °C, elle est de 61 % à 51 pcm, au-dessus des 54 % prévus à la section 9.32 du Code pour le Grand Montréal. Il consomme 55 W au débit d'essai et jusqu'à 104 W en haute vitesse. L'estimation annuelle de la fiche est de 482 kWh.
Dimensions
- 23,16 × 20,75 × 10,06 po, 35 lb.
- Largeur hors tout avec le volet : 25 po.
- Raccords latéraux de 5 po.
- Aucun drain.
- Dégagements : 8 1/2 po devant la porte et 2 3/8 po au-dessus du boîtier électrique.
- Montage au plafond ou au mur avec le support fourni.
Le lavage du noyau
Le noyau à membrane se lave à l'eau, ce qui est rare. On ouvre les deux loquets sous l'appareil, on retire la porte, puis le noyau et les filtres. Le noyau se place dans un grand évier ou une baignoire, une entrée vers le bas, et on y verse de l'eau du robinet jusqu'à ce qu'elle ressorte claire. On répète par l'autre entrée, puis on le laisse sécher deux à trois heures, plaques à la verticale. Fantech recommande de l'examiner tous les six mois.
Commandes pour une maison familiale
Dans une maison de ville, nous proposons souvent une commande murale et des minuteries. La commande ECO-Touch Auto IAQ, à écran tactile, règle la ventilation selon les COV et permet de fixer une plage d'humidité pour le jour et pour la nuit. Des minuteries RTS2, RTS4 ou RTS5 dans les salles de bain font passer l'appareil en haute vitesse; jusqu'à cinq peuvent être branchées. L'appareil suit toujours la même priorité : arrêt à distance, minuterie, déshumidistat, puis commande murale.
Filtres
Deux filtres MERV 3 lavables de 11 5/16 × 8 1/8 po sont fournis; des MERV 8 (461674) et MERV 13 (461675) sont offerts. Ils se lavent à l'eau tiède savonneuse, puis sèchent complètement avant d'être remis en place.
Garantie
Fantech couvre le noyau, les composants électriques et le moteur du volet 5 ans, et les moteurs des ventilateurs 7 ans.
Notre travail dans le Grand Montréal
Nos équipes installent des VRE dans les jumelés et les maisons de ville de Montréal, de Laval, de Longueuil, de la Rive-Nord et de la Rive-Sud. Pour un jumelé, nous faisons le calcul pièce par pièce selon CSA F326 pour chaque unité, nous choisissons la version standard ou -M selon le plan, puis nous équilibrons chaque appareil au débit calculé, soufflerie en marche.
Le FIT 120E-D-M porte le no 2005060 et il est homologué à la section III du répertoire HVI. Chaque propriétaire d'un jumelé peut ainsi être admissible à l'aide Rénoclimat de 500 $, si la cote ÉnerGuide de sa maison s'améliore entre les deux évaluations; l'évaluation doit être faite avant le début des travaux.