Fantech ERV FIT 120E-D-M Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-DBuilt-in motorized outdoor air damper
The -D suffix means the FIT 120E-D-M has a built-in motorized damper. When the unit is tied to a furnace return, it can block the unconditioned outdoor air the blower would otherwise pull in while the unit is off, which Fantech recommends for that type of installation. The damper brings the width to 25 in, versus 24 5/8 in for the FIT 120E-M.
-MMirrored version: dwelling-side ports on the left
On the FIT 120E-D, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-D-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005060Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 35 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005060) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005060
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005060). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
For semi-detached and row houses built as mirror images
In a semi-detached home or a row of townhouses, every other unit is often the mirror image of its neighbour. The Fantech FIT 120E-D-M is designed for these layouts: its supply and return air connect on the left side, and it has a built-in motorized damper so it can be connected to a furnace return. With a net airflow of 127 cfm at 0.4 in. (146 cfm at 0.2 in.), it is the large size of the FIT series. Its cabinet is only 10.06 in. thick, which leaves room under basement joists.
Connecting to the furnace
With a partially dedicated installation, fresh air from this ERV enters the return plenum and the furnace tempers it before distributing it. Stale air is drawn from the wet rooms. The damper closes when the unit is not ventilating, so the blower does not pull cold outdoor air through it. We interlock the blower with the unit's NO, C, NC relay, or set it to run continuously.
Exhaust grilles go in the bathroom, the kitchen or the laundry room, high on the wall or on the ceiling.
Left-hand orientation
The side the connections are on determines the routing of every duct. With the right version, ducts stay short, with 45° elbows and Y fittings as Fantech recommends, which preserves airflow and limits noise. The manual's diagrams apply when reversed. The mirror version has its own wiring diagram, and we follow it to the letter.
Performance and power consumption
This energy recovery ventilator shows a sensible recovery efficiency of 74% at 0 °C (51 cfm) and 81% adjusted. At −25 °C, it is 61% at 51 cfm, above the 54% set in section 9.32 of the Code for Greater Montreal. It draws 55 W at the test airflow and up to 104 W at high speed. The annual estimate in the spec sheet is 482 kWh.
Dimensions
- 23.16 × 20.75 × 10.06 in., 35 lb.
- Overall width with the damper: 25 in.
- 5 in. side connections.
- No drain.
- Clearances: 8 1/2 in. in front of the door and 2 3/8 in. above the electrical box.
- Ceiling or wall mounting with the supplied bracket.
Washing the core
The membrane core can be washed with water, which is rare. Open the two latches under the unit, remove the door, then the core and the filters. Place the core in a large sink or a bathtub, one inlet facing down, and pour tap water into it until it runs out clear. Repeat through the other inlet, then let it dry for two to three hours with the plates vertical. Fantech recommends inspecting it every six months.
Controls for a family home
In a townhouse, we often suggest a wall control and timers. The ECO-Touch Auto IAQ touchscreen control adjusts ventilation based on VOCs and lets you set a humidity range for daytime and for nighttime. RTS2, RTS4 or RTS5 timers in the bathrooms switch the unit to high speed; up to five can be connected. The unit always follows the same priority: remote off, timer, dehumidistat, then wall control.
Filters
Two washable 11 5/16 × 8 1/8 in. MERV 3 filters are supplied; MERV 8 (461674) and MERV 13 (461675) filters are available. They are washed in warm soapy water, then dried completely before being put back in place.
Warranty
Fantech covers the core, the electrical components and the damper motor for 5 years, and the fan motors for 7 years.
Our work in Greater Montreal
Our crews install ERVs in semi-detached homes and townhouses in Montreal, Laval, Longueuil, the North Shore and the South Shore. For a semi-detached home, we do the room-by-room calculation under CSA F326 for each dwelling, choose the standard or -M version according to the plan, then balance each unit to the calculated airflow, with the blower running.
The FIT 120E-D-M is listed in Section III of the HVI directory under no. 2005060, which makes its airflows and efficiencies verifiable by anyone. Note that since October 1, 2026, installing an HRV or an ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.
Free quote at 514 316-2973 or sales@airgreen.ca.