Fantech ERV FIT 120E-HC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-HCHard-connect version shipped without a cord
The -HC (hard connect) suffix means the unit ships with no power cord and is wired directly to the circuit where code requires it. On the FIT 120E-HC, the supply wires enter the electrical box through a 3/8 in cable fastener and connect to the unit's leads and ground screw.
RelayNO / C / NC terminals to interlock the furnace
The FIT 120E-HC has NO, C and NC relay terminals to interlock the furnace blower: contact is made between NO and C when the unit ventilates, and between NC and C in standby. Fantech requires the furnace to run continuously or be interlocked this way when the unit is tied to its return.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005117Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005117) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005117
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005117). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Large size, hard-wired connection
The Fantech FIT 120E-HC is an energy recovery ventilator (ERV) supplied without a power cord. It is meant for projects where the code or the specifications call for a permanent connection to the circuit, in a home that needs more airflow than an 80 size. It delivers 127 cfm of net airflow at 0.4 in. (146 cfm at 0.2 in.).
It keeps the connections serving the home on the right side, like the standard model, and has no motorized damper.
The electrical connection
Fantech's manual describes the procedure: remove the electrical compartment cover, install a 3/8 in. cable clamp, bring in the circuit wires, connect them to the unit's wires and grounding screw, then close up without pinching the wires. Power is then turned on at the panel. On the commissioning report, the connection type is recorded as hard-wired. We plan this work with the electrician on the job site.
The furnace relay
The FIT 120E-HC terminal block includes NO, C and NC relay terminals. In ventilation, the contact closes between NO and C; in standby, between NC and C. It is used to start a furnace blower whenever the unit is ventilating. Fantech calls for the blower to run continuously or to be interlocked this way as soon as the ERV is connected to its return.
Since this model has no damper, the manufacturer also calls for running it continuously in this type of installation. If the occupant needs to be able to turn it off, we suggest the FIT 120E-D-HC instead, which adds the motorized damper.
Timers and dehumidistat
The same terminal block accepts bathroom timers. The RTS2 starts twenty minutes of high speed; the RTS4 and RTS5 offer 20, 40 or 60 minutes. Up to five timers can be connected to the unit. An MDEH1 dehumidistat forces high speed when humidity rises above the setting.
Location and ducts
Fantech recommends installing the unit in a mechanical room, near the air handling system or in the basement, in a space that stays above 10 °C. It is kept near an exterior wall, to shorten the ducts to the hoods, and away from the bedrooms. The main ducts are at least the diameter of the connections, i.e. 5 in., and the branches to the rooms at least 4 in. For noise, the manual calls for few elbows, 45° elbows and Y fittings. All joints are screwed or sealed, then wrapped with aluminum tape.
No clothes dryer or kitchen range hood may be connected to the ERV duct system; doing so voids the warranty.
Performance
- At 0 °C and 51 cfm: 74% sensible recovery efficiency, 81% as an adjusted value.
- At −25 °C: 61% at 51 cfm, above the 54% minimum set in section 9.32 of the Code for Greater Montreal.
- Total recovery in summer: 64% at 35 °C.
- Power draw: 55 W at the test airflow, or 0.9 cfm/W.
Without a wall control
If no wall control is planned, the unit's selector is enough. The MIN and MAX positions maintain continuous ventilation, at low or high speed, as long as no priority function takes over; AUTO puts the unit on standby. In an occupied home, a wall control is still the better choice: the occupant adjusts the ventilation without opening a closet.
Space requirements
Cabinet of 23.16 × 20.75 × 10.06 in., 34 lb, side connection through four round 5 in. ports. It needs no drain. Leave 8 1/2 in. in front of the door to take out the core, and 2 3/8 in. above the electrical box for the wiring.
Filters
Two electrostatic MERV 3 filters (11 5/16 × 8 1/8 in.), washable. For finer filtration, Fantech offers MERV 8 (461674) and MERV 13 (461675) filters.
Warranty
7 years on the fan motors; 5 years on the core and electrical components.
Installation by AirGreen in Greater Montreal
We serve Montreal, Laval, Longueuil, the North Shore and the South Shore. For each project, a room-by-room calculation under CSA F326 sets the airflow to deliver. We choose the installation method based on how the house is heated, then balance supply and exhaust to the calculated airflow.
The FIT 120E-HC is certified in Section III of the HVI directory (no. 2005117): its airflows and efficiencies are published and verifiable by anyone. Rénoclimat stopped funding HRVs and ERVs on October 1, 2026, except for files already open under the program's transition rules.
To request a free quote, call 514 316-2973 or write to sales@airgreen.ca.