Échangeur d'Air Fantech ERV FIT 120E-M | Montréal, Laval, Longueuil, Rive Sud et Rive Nord
Is it the right size for your home?
It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$53.68
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
-MMirrored version: dwelling-side ports on the left
On the FIT 120E, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.
1%Balancing set in 1% steps
The FIT 120E-M is balanced with a Fantech programmable touchscreen wall control and a manometer. Each press changes fan speed by 1%; the installer sets high speed and the low and medium speeds follow automatically.
61%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
ERVIt moves moisture too, not just heat
An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.
2005059Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it, and it's the first condition for the Rénoclimat grant.
−19 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm. Most spec sheets show only the first number, precisely because it looks better.
55 WMeasured at the airflow it actually runs at
Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.
5 yearsThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years. We register the warranty in your name at commissioning.
5 inWhat it needs on site
5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat: $500 to install or replace an HRV or ERV
First condition met: HVI Section III certified, No. 2005059. Second: your EnerGuide rating must improve between the two evaluations. Québec warns that an air exchanger installed on its own can increase a home's energy use; that's why we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 146 cfm
- Net airflow at 0.4 in. w.g.
- 127 cfm
- SRE at 0 °C (51 cfm)
- 74%
- SRE at −25 °C (51 cfm)
- 61%
- ASE at 0 °C
- 81%
- Power draw
- 55 W
- Efficacy
- 0.9 cfm/W
- Type
- ERV
- Connection
- Side ports
- Duct collars
- 5 in
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
- Dimensions (L × D × H)
- 23.16 × 20.75 × 10.06 in
- Weight
- 34 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2005059
- Warranty — core
- 5 years
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005059). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Un VRE de 127 pcm pour les logements en plan inversé
Le Fantech FIT 120E-M est la version miroir du FIT 120E. Sur le modèle standard, l'alimentation et le retour d'air du logement se raccordent à droite; ici, ils sont à gauche. Dans un immeuble où les unités sont construites en symétrie, cette version garde un tracé de conduits court et direct dans chaque logement, quel que soit son côté.
C'est un ventilateur récupérateur d'énergie (VRE) de grand format : débit net de 127 pcm à 0,4 po, 146 pcm à 0,2 po, raccords de 5 po. Il n'a pas de volet motorisé et il est livré avec cordon. Il convient donc d'abord à une installation entièrement dédiée, avec plinthes électriques, plancher radiant ou thermopompe murale.
Un équilibrage au pour cent près
Le FIT 120E-M s'équilibre avec une commande murale Fantech programmable à écran tactile et un manomètre. En mode d'équilibrage, chaque pression sur les flèches change la vitesse du ventilateur de 1 %. L'installateur règle l'évacuation, puis l'alimentation, en haute vitesse seulement; les vitesses basse et moyenne suivent automatiquement. Ce réglage fin compte dans un immeuble où la longueur des conduits varie d'une unité à l'autre : chaque appareil est ajusté à son propre réseau.
Rendement
À 0 °C et 51 pcm, l'efficacité de récupération sensible est de 74 %, ou 81 % en valeur ajustée. À −25 °C, toujours à 51 pcm, elle est de 61 %. La section 9.32 du Code demande au moins 54 % à cette température dans le Grand Montréal : l'appareil a de la marge. La récupération totale atteint 64 % à 35 °C, ce qui limite l'humidité qui entre l'été.
Électricité
55 W au débit d'essai (0,9 pcm/W), 104 W en haute vitesse, courant maximal de 1,4 A. La plage de débit s'étend de 40 à 127 pcm, et l'appareil se branche sur une prise ordinaire de 120 V avec son cordon. La fiche ci-dessus estime 482 kWh par an.
Pourquoi un VRE dans un logement neuf
Un logement neuf est étanche : l'air ne se renouvelle plus par les fissures. Le VRE remplace l'air vicié par de l'air extérieur et récupère au passage une partie de la chaleur et de l'humidité. En hiver, l'air neuf entre donc moins sec qu'avec une simple extraction; en été, une part de l'humidité extérieure reste dehors. Le noyau du FIT 120E-M fait ce travail à travers une membrane polymère qui tolère le gel et se lave à l'eau.
Quand il fait très froid, l'appareil protège ce noyau : son cycle de dégivrage arrête le ventilateur d'alimentation et laisse l'air vicié, plus chaud, dégager le noyau. Aucun drain n'est requis.
Où le placer
Fantech recommande une salle mécanique, un local technique ou un sous-sol, dans un espace qui reste au-dessus de 10 °C. L'appareil doit être près d'un mur extérieur pour les hottes, près d'une prise de 120 V et loin des pièces principales. Au plafond comme au mur, il se fixe sur les solives ou les montants avec le support long et les deux équerres fournis.
Installation
- 23,16 × 20,75 × 10,06 po, 34 lb.
- Raccordement latéral, conduits de 5 po; branches vers les pièces d'au moins 4 po.
- Pas de drain.
- 8 1/2 po libres devant la porte pour retirer le noyau.
Entretien
Les deux filtres MERV 3 fournis (11 5/16 × 8 1/8 po) sont électrostatiques et lavables. En option : MERV 8 (461674) ou MERV 13 (461675). Le calendrier Fantech prévoit l'examen des filtres tous les trois mois et celui du noyau tous les six mois. Une fois par an, on passe l'aspirateur à l'intérieur de l'appareil, on nettoie les hottes et les conduits, et un entrepreneur qualifié fait une visite générale.
Garantie
5 ans sur le noyau et les composants électriques, 7 ans sur les moteurs des ventilateurs. Pour commander une pièce, le numéro de série inscrit sur la plaque signalétique suffit.
AirGreen à Montréal, à Laval et à Longueuil
Nous installons le FIT 120E-M dans les logements et les maisons de ville de Montréal, de Laval, de Longueuil, de la Rive-Nord et de la Rive-Sud. Le débit à fournir vient d'un calcul pièce par pièce selon la norme CSA F326; nous vérifions l'orientation des raccords sur le plan, puis nous équilibrons l'appareil au manomètre jusqu'au débit calculé.
Inscrit sous le no 2005059 à la section III du répertoire HVI, le FIT 120E-M peut être admissible à l'aide Rénoclimat de 500 $, si la cote ÉnerGuide s'améliore entre les deux évaluations. L'évaluation doit être faite avant le début des travaux.
Soumission gratuite : 514 316-2973, sales@airgreen.ca.