Fantech ERV FIT 120E-M Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore

In stock
SKU: FIT 120E-M
127 cfm net1,500 to 2,400 sq ft61% at −25 °C
Talk to an HVAC technician · 514 316-2973
Meets the Québec CodeCore warranty: 5 years
01 · Your home

Is it the right size for your home?

It delivers 127 cfm net, enough to ventilate 1,500 to 2,400 sq ft. Choose your home's living area.

It's the right size.

For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 127 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.

Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.

02 · Performance

What it does, in numbers

Heat recovery
61%
At −25 °CCode: 54% minimum
74%
At 0 °CCertified at 51 cfm
Net airflowThe ducts cost it 19 cfm
0.2 in · test bench146 cfm
0.4 in · with ducts127 cfm

$53.68

Electricity per year

Less than a 60 W light bulb

Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.

55W
Running continuously
482kWh
Per year
3months
Filter cleaning

Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 61% at 51 cfm.

Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 55 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

-MMirrored version: dwelling-side ports on the left

On the FIT 120E, the dwelling's supply and return air connect on the right-hand side; on the FIT 120E-M, they move to the left. One building can thus serve mirror-image floor plans, with the installation drawings simply read in reverse.

1%Balancing set in 1% steps

The FIT 120E-M is balanced with a Fantech programmable touchscreen wall control and a manometer. Each press changes fan speed by 1%; the installer sets high speed and the low and medium speeds follow automatically.

61%What it still recovers at −25 °C

The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.

ExhaustIt defrosts by pausing the fresh air for a few minutes

In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.

ERVIt moves moisture too, not just heat

An ERV transfers some moisture between the two airstreams. Useful in a house that gets too dry in winter or takes on a lot of humidity in summer. The trade-off: it generally recovers less heat than a comparable HRV.

2005059Its HVI certification number

Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.

−19 cfmWhat the ducts cost it

Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 146 to 127 cfm.

55 WMeasured at the airflow it actually runs at

Its 74% at 0 °C is certified at 51 cfm, the continuous airflow of a typical home. At that setting it draws 55 W, or about 482 kWh a year.

5 yearsThe core warranty

The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.

5 inWhat it needs on site

5 in ducts, side connection. It weighs 34 lb, and it needs enough clearance to slide the core out once a year.

Financial aid

Rénoclimat stopped funding HRVs and ERVs on October 1, 2026

Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2005059) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.

04 · Installation

What it needs on site

5 in ductsCollar diameter
Side connectionSide ports
34 lbUnit weight
23.16 × 20.75 × 10.06 inLength × depth × height
120 VPower supply

In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.

Complete spec sheetData and cited sources
Net airflow at 0.2 in. w.g.
146 cfm
Net airflow at 0.4 in. w.g.
127 cfm
SRE at 0 °C (51 cfm)
74%
SRE at −25 °C (51 cfm)
61%
ASE at 0 °C
81%
Power draw
55 W
Efficacy
0.9 cfm/W
Type
ERV
Connection
Side ports
Duct collars
5 in
Defrost cycle
Exhaust only (supply fan off)
Filters
2 washable electrostatic MERV 3 panel filters (11 5/16 × 8 1/8 in); optional MERV 8 (461674) and MERV 13 (461675)
Dimensions (L × D × H)
23.16 × 20.75 × 10.06 in
Weight
34 lb
Power supply
120 V
HVI certification (Section III)
2005059
Warranty — core
5 years
Warranty — motors
7 years
Warranty — parts
5 years
Spec sheet (French)
PDF
Spec sheet (English)
PDF

Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2005059). Annual consumption calculated at 55 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the Fantech range

The next model down and up

Talk to an HVAC technician before you choose

We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.

A 127 cfm ERV for units with a reversed floor plan

The Fantech FIT 120E-M is the mirror version of the FIT 120E. On the standard model, the supply and return connections serving the home are on the right; here, they are on the left. In a building where the units are built as mirror images, this version keeps a short, direct duct run in every home, whichever side it is on.

It is a large-size energy recovery ventilator (ERV): net airflow of 127 cfm at 0.4 in., 146 cfm at 0.2 in., 5 in. connections. It has no motorized damper and it comes with a cord. So it is suited first and foremost to a fully dedicated installation, with electric baseboards, radiant floor heating or a wall-mounted heat pump.

Balancing to the nearest percent

The FIT 120E-M is balanced with a programmable Fantech touchscreen wall control and a manometer. In balancing mode, each press on the arrows changes the fan speed by 1%. The installer sets the exhaust, then the supply, at high speed only; the low and medium speeds follow automatically. This fine adjustment matters in a building where duct length varies from one unit to the next: each ventilator is set to its own duct system.

Performance

At 0 °C and 51 cfm, sensible recovery efficiency is 74%, or 81% as an adjusted value. At −25 °C, still at 51 cfm, it is 61%. Section 9.32 of the Code requires at least 54% at that temperature in Greater Montreal: the unit has room to spare. Total recovery reaches 64% at 35 °C, which limits the humidity that comes in during the summer.

Electrical

55 W at the test airflow (0.9 cfm/W), 104 W at high speed, maximum current of 1.4 A. The airflow range extends from 40 to 127 cfm, and the unit plugs into an ordinary 120 V outlet with its cord. The spec sheet above estimates 482 kWh per year.

Why an ERV in a new home

A new home is airtight: air no longer gets renewed through cracks. The ERV replaces stale air with outdoor air and, along the way, recovers part of the heat and humidity. In winter, the fresh air therefore comes in less dry than with simple exhaust; in summer, part of the outdoor humidity stays outside. The FIT 120E-M core does this work through a polymer membrane that tolerates freezing and can be washed with water.

When it is very cold, the unit protects that core: its defrost cycle stops the supply fan and lets the warmer stale air clear the core. No drain is required.

Where to put it

Fantech recommends a mechanical room, a utility room or a basement, in a space that stays above 10 °C. The unit should be near an exterior wall for the hoods, near a 120 V outlet and away from the main living areas. On the ceiling or on the wall, it fastens to the joists or studs with the long bracket and the two angle brackets supplied.

Installation

  • 23.16 × 20.75 × 10.06 in., 34 lb.
  • Side connection, 5 in. ducts; branches to the rooms at least 4 in.
  • No drain.
  • 8 1/2 in. of clearance in front of the door to remove the core.

Maintenance

The two MERV 3 filters supplied (11 5/16 × 8 1/8 in.) are electrostatic and washable. Optional: MERV 8 (461674) or MERV 13 (461675). Fantech's schedule calls for inspecting the filters every three months and the core every six months. Once a year, the inside of the unit is vacuumed, the hoods and ducts are cleaned, and a qualified contractor does a general check-up.

Warranty

5 years on the core and electrical components, 7 years on the fan motors. To order a part, the serial number on the nameplate is all you need.

AirGreen in Montreal, Laval and Longueuil

We install the FIT 120E-M in apartments and townhouses in Montreal, Laval, Longueuil, the North Shore and the South Shore. The airflow to deliver comes from a room-by-room calculation under the CSA F326 standard; we check the orientation of the connections on the plan, then balance the unit with a manometer to the calculated airflow.

In the HVI directory, the FIT 120E-M is certified in Section III (no. 2005059): anyone can check its airflows and efficiencies there. Since October 1, 2026, Rénoclimat no longer funds the installation of an HRV or an ERV; only files already open under the program's transition rules remain eligible.

Free quote: 514 316-2973, sales@airgreen.ca.