Fantech HRV ATMO 200H Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 189 cfm net, enough to ventilate 2,300 to 3,600 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 189 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$48.80
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 60% at 64 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 50 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
22 inCore removal: 22 in in front of the door
The ATMO 200H's core comes out through the front door, held by two latches under the unit. Fantech calls for 22 in (559 mm) free in front of the unit to pull it out, and 2 3/8 in above the electrical box for wiring.
DamperConnector ready for a motorized damper
When tied to a furnace return, the ATMO 200H can let the blower pull in outdoor air while the unit is off; Fantech then recommends a motorized damper. The electrical box has an auxiliary connector for this accessory damper, and the wire harness is supplied.
60%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 64 cfm.
ExhaustIt defrosts by pausing the fresh air for a few minutes
In cold weather, the supply fan stops for a few minutes while the exhaust keeps running, so warm indoor air thaws the core. During the cycle the house is briefly under negative pressure; if you have a fireplace or a naturally vented combustion appliance, mention it to our estimator.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.
2505286Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−44 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 233 to 189 cfm.
50 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 66 cfm, the continuous airflow of a typical home. At that setting it draws 50 W, or about 438 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, side connection and a condensate drain. It weighs 46 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2505286) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 233 cfm
- Net airflow at 0.4 in. w.g.
- 189 cfm
- SRE at 0 °C (66 cfm)
- 75%
- SRE at −25 °C (64 cfm)
- 60%
- ASE at 0 °C
- 81%
- Power draw
- 50 W
- Efficacy
- 1.3 cfm/W
- Type
- HRV
- Connection
- Side ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Exhaust only (supply fan off)
- Filters
- 2 washable electrostatic MERV 3 panel filters; optional MERV 8 (463945) and MERV 13 (463946)
- Dimensions (L × D × H)
- 23.88 × 16.94 × 21.44 in
- Weight
- 46 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505286
- Warranty — core
- Lifetime
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505286). Annual consumption calculated at 50 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
An HRV designed to connect to the furnace
Many homes in Greater Montreal already have a forced-air furnace and its ductwork. The Fantech ATMO 200H is a heat recovery ventilator (HRV) that can use that system to distribute fresh air. Its net airflow is 189 cfm at 0.4 in., and 233 cfm at 0.2 in.
Its connections are on the sides and it is 21.44 in. high, which makes it easier to install next to the furnace, in a mechanical room that is already crowded.
A connector ready for a motorized damper
When an air exchanger is connected to a furnace return, there is a trap. If the ATMO 200H is off, the furnace blower keeps drawing outdoor air through it, without any stale air going out to warm it. Untreated cold air then enters the house and the furnace works harder.
In that case, Fantech recommends a motorized damper. The ATMO 200H's electrical box has an auxiliary connector for this damper, sold as an accessory, and the wiring harness is supplied with the unit. We install it whenever the unit can be turned off by the occupant.
Fantech also specifies that the blower must run continuously or be interlocked with the unit when ventilation is needed. If your furnace has a variable-speed EC blower motor, power consumption stays reasonable; otherwise, a fully dedicated installation is preferable. We check this point before the quote.
Core removal: 22 in. in front of the door
The core comes out through the front door, which is held by two latches at the bottom of the unit. Fantech calls for 22 in. of clear space in front of the unit to remove it, and 2 3/8 in. above the electrical box for wiring. Next to a furnace, those 22 in. must stay clear.
Efficiency and power consumption
According to HVI, sensible recovery efficiency is 75% at 66 cfm and 0 °C, and adjusted sensible efficiency is 81%. At −25 °C, it remains at 60% (measured at 64 cfm), above the 54% threshold of section 9.32 of the Québec Construction Code for Greater Montreal.
At the 66 cfm test point, it draws 50 W, or 1.3 cfm/W. Running continuously, that comes to about 438 kWh per year, roughly $49 at Hydro-Québec Rate D (11.142¢/kWh).
Defrost works by stopping the supply fan: fresh air stops coming in and the exhaust fan switches to high speed to clear the core.
Installation
- Dimensions: 23.88 × 16.94 × 21.44 in. (L × D × H)
- Weight: 46 lb
- Connections: 6 in., round, side, with sliding ISF collars
- Power supply: 120 V
- Drain: required, tube supplied
Like any HRV, it must be connected to a drain. It hangs with the supplied chains or mounts on the wall on the bracket. With the collars, it is 29 1/2 in. wide overall.
Filters
Two washable electrostatic MERV 3 filters are supplied, to be washed in warm soapy water. Optional: MERV 8 (463945) and MERV 13 (463946). According to Fantech's filter guide, a MERV 8 usually reduces airflow by 10 to 15%, and a MERV 13 by 15 to 20%. If the unit is connected to the furnace, the furnace filter adds to that: we take both into account.
The core is cross-flow, as on all ATMO units. It comes out through the front door along with the filters.
Warranty
Fantech warrants the core for life, the fan motors for 7 years, and the electrical components and the damper motor for 5 years. The unit is designed for residential use only.
The ATMO 200H is certified in section III of the HVI directory (number 2505286): its airflows and efficiencies are published and can be checked by anyone. Note that since October 1, 2026, installing an HRV or an ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.
Installation by AirGreen in Greater Montreal
We first calculate the required airflow room by room, under the CSA F326 standard. Then we decide with you: a fully dedicated installation or a connection to the furnace, with a motorized damper. Both can be done; the right choice depends on your blower and your ducts.
At commissioning, we balance the unit with a manometer, with the blower running, to the calculated airflow. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.
Free quote: 514 316-2973 or sales@airgreen.ca.