Fantech HRV HERO 200H Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 203 cfm net, enough to ventilate 2,400 to 3,800 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 203 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$95.65
Electricity per year
Less than a 100 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 67% at 87 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 98 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
16 inCore removal: 16 in free in front of the door
The HERO 200H's core and filters come out through the front door, held by two latches under the unit. Fantech calls for 16 in (406 mm) in front of the door to remove the core, and 2 3/8 in above the electrical box for wiring.
LoopDrain tube supplied, installed with a loop
The HERO 200H comes with its drain tube. It attaches to the unit's fitting, then a loop is formed in it as shown in Fantech's drawing before it is routed to the drain.
67%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 87 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.
2505147Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 220 to 203 cfm.
98 WMeasured at the airflow it actually runs at
Its 80% at 0 °C is certified at 85 cfm, the continuous airflow of a typical home. At that setting it draws 98 W, or about 858 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection and a condensate drain. It weighs 59 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2505147) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 220 cfm
- Net airflow at 0.4 in. w.g.
- 203 cfm
- SRE at 0 °C (85 cfm)
- 80%
- SRE at −25 °C (87 cfm)
- 67%
- ASE at 0 °C
- 88%
- Power draw
- 98 W
- Efficacy
- 0.9 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable electrostatic MERV 3 panel filters; optional MERV 8 (428527) or MERV 13 (428549), not washable
- Dimensions (L × D × H)
- 27.88 × 15.38 × 24.88 in
- Weight
- 59 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505147
- Warranty — core
- Lifetime
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505147). Annual consumption calculated at 98 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
A 203 cfm HRV for large homes
When the house has four or five bedrooms and a finished basement, small units are no longer enough. The Fantech HERO 200H is a heat recovery ventilator (HRV) that delivers a net airflow of 203 cfm at 0.4 in., and 220 cfm at 0.2 in.
It is the largest HERO with conventional motors. It shares its cabinet with the HERO 250H-EC, which uses EC motors. The choice between the two comes down to the airflow you need and the power consumption you are willing to pay for every year.
67% efficiency at −25 °C
According to HVI, the sensible recovery efficiency of the HERO 200H is still 67% at −25 °C (measured at 87 cfm). That is the best extreme-cold result among the HERO models without EC motors, and it is above the 54% threshold in section 9.32 of the Québec Construction Code for Greater Montreal.
At 0 °C, the sensible recovery efficiency is 80% at 85 cfm, and the adjusted sensible efficiency is 88%. Defrost works by recirculation: an internal damper opens on the indoor side and house air clears the core, without drawing in outdoor air during the cycle.
Power consumption: the honest figures
At the 85 cfm HVI test point, the HERO 200H draws 98 W, or 0.9 cfm/W. Running continuously, that comes to about 858 kWh per year, roughly $96 of electricity at Hydro-Québec Rate D (11.142¢/kWh). It is the highest figure in the HERO series.
At the same 85 cfm test airflow, the HERO 250H-EC draws 34 W. If the unit is going to run continuously for fifteen years, that gap is worth calculating with us. We present both prices so you can compare over the long run, not just at purchase.
Core removal: 16 in. in front of the door
The core and filters come out through the front door, held by two latches at the bottom of the unit. Fantech calls for 16 in. of free space in front of the door to remove the core, and 2 3/8 in. above the electrical box. With a cabinet 15.38 in. deep, the unit takes up real space: it has to be planned into the mechanical room from the start.
Installation
- Dimensions: 27.88 × 15.38 × 24.88 in. (L × D × H)
- Weight: 59 lb
- Connections: 6 in., round, on top (vertical connection)
- Power supply: 120 V
- Drain: required, tube supplied
The drain tube is supplied. It attaches to the unit's fitting, then is formed into a loop, following Fantech's diagram, before being routed to the drain. At this airflow, the main ducts must be the same diameter as the 6 in. connections or larger, with 45° elbows and Y fittings.
Filters
The HERO 200H comes with two washable electrostatic MERV 3 filters, to be washed in warm, soapy water. Options: MERV 8 (428527) or MERV 13 (428549), which are not washable. In a large home with pets, a MERV 8 is often a good compromise between filtration and airflow. MERV 8 and MERV 13 filters are replaced instead of washed; keep a spare set on hand.
The unit mounts on the wall on the supplied bracket or hangs from the joists with chains and springs, two methods described in Fantech's manual.
Warranty
Fantech warrants the core for life, the fan motors for 7 years, and the electrical components and the damper motor for 5 years. The unit is designed for residential use only.
The HERO 200H is certified in Section III of the HVI directory (number 2505147): its airflows and efficiencies are published and anyone can check them. Note that since October 1, 2026, installing an HRV or ERV is no longer eligible for Rénoclimat assistance, except for files opened before that date under the transition rules.
Installation by AirGreen in Greater Montreal
For a large home, the room-by-room calculation of the CSA F326 standard is essential: it tells how many cfm each bedroom and each bathroom needs, and therefore whether 203 cfm is right. We present the HERO 200H and the HERO 250H-EC side by side if both are suitable.
Once the unit is installed, we balance each fan with a manometer, to the calculated airflow. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore.
For a free quote, call 514 316-2973 or write to sales@airgreen.ca.