Fantech HRV HERO 150H-EC Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 172 cfm net, enough to ventilate 2,000 to 3,200 sq ft. Choose your home's living area.
It's the right size.
For a 2,500 to 3,200 sq ft home, about 150 cfm of air needs to be renewed continuously. This unit delivers 172 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. Our estimator sets the exact airflow room by room, following CSA F326.
What it does, in numbers
$22.45
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets the Québec Construction Code everywhere in the province. The Code requires 54% at −25 °C below 6,000 degree-days (Montréal, Laval, Longueuil and both shores) and 60% above that. This unit is rated at 68% at 66 cfm.
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 23 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
ECMEC motors: 3.0 cfm/W versus 1.2
The HERO 150H-EC uses the HERO 150H cabinet with electronically commutated motors. Fantech's guide gives it 3.0 cfm/W fan efficacy at 0 °C, versus 1.2 for the HERO 150H, and up to 172 cfm at 0.4 in instead of 150.
1%Touchscreen balancing in 1% steps
Fantech has the HERO 150H-EC balanced with its programmable touchscreen wall control and a manometer. Each press changes speed by 1%; both fans are set at high speed and the low and medium speeds follow automatically.
68%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 66 cfm.
DamperIt defrosts without depressurizing the house
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. The house doesn't go into negative pressure during the cycle: no cold air drawn in through leaks, and none of the imbalance manufacturers warn about when there's a fireplace or a combustion appliance.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a home almost always has too much humidity, not too little.
2505258Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−17 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 189 to 172 cfm.
23 WMeasured at the airflow it actually runs at
Its 84% at 0 °C is certified at 70 cfm, the continuous airflow of a typical home. At that setting it draws 23 W, or about 201 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors: 7 years. Parts: 5 years.
6 inWhat it needs on site
6 in ducts, top connection and a condensate drain. It weighs 51 lb, and it needs enough clearance to slide the core out once a year.
Rénoclimat stopped funding HRVs and ERVs on October 1, 2026
Only files opened before that date, under the program's transition rules, remain eligible. This unit's HVI Section III certification (No. 2505258) remains the public proof of its performance: we balance it to the calculated airflow rather than running it at full speed.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 189 cfm
- Net airflow at 0.4 in. w.g.
- 172 cfm
- SRE at 0 °C (70 cfm)
- 84%
- SRE at −25 °C (66 cfm)
- 68%
- ASE at 0 °C
- 86%
- Power draw
- 23 W
- Efficacy
- 3.0 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable electrostatic MERV 3 panel filters (7 7/8 × 9 13/16 in); optional MERV 8 (428526) or MERV 13 (428548), not washable
- Dimensions (L × D × H)
- 27.88 × 13.38 × 24.88 in
- Weight
- 51 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505258
- Warranty — core
- Lifetime
- Warranty — motors
- 7 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505258). Annual consumption calculated at 23 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We calculate the airflow room by room, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The HERO that uses the least power per cfm
The Fantech HERO 150H-EC is a heat recovery ventilator (HRV) with electronically commutated motors. It uses the HERO 150H cabinet, but its net airflow rises to 172 cfm at 0.4 in., and 189 cfm at 0.2 in.
Its strength is power consumption. For a family that runs its air exchanger day and night, as it should be run, it is the unit in the series that costs the least to operate for the airflow it delivers.
EC motors: 3.0 cfm/W versus 1.2
Fantech's selection guide gives the HERO 150H-EC a fan efficiency of 3.0 cfm/W at 0 °C, versus 1.2 for the HERO 150H. It is the highest value in the entire HERO and ATMO range. The airflow range at 0.4 in. also rises from 50–150 cfm to 50–172 cfm.
In HVI testing, it draws 23 W at 70 cfm. Running continuously, that comes to about 201 kWh per year, roughly $22 at Hydro-Québec Rate D (11.142¢/kWh). The HERO 150H, in the same cabinet, is estimated at about $59 per year. Over the life of the unit, the difference adds up.
The best extreme-cold performance in the series
According to HVI, the sensible recovery efficiency of the HERO 150H-EC is 84% at 70 cfm and 0 °C, with an adjusted sensible efficiency of 86%. At −25 °C, it is still 68% (measured at 66 cfm), the highest figure in the HERO series. That is well above the 54% threshold in section 9.32 of the Québec Construction Code for Greater Montreal.
Defrost works by recirculation: an internal damper opens on the indoor side and house air clears the core, without drawing in outdoor air during the cycle.
Touchscreen balancing, in 1% steps
Fantech has the HERO 150H-EC balanced with its programmable touchscreen wall control and a manometer. Each press changes the speed by 1%. Both fans are adjusted at maximum speed; the low and medium speeds follow automatically.
Installation
- Dimensions: 27.88 × 13.38 × 24.88 in. (L × D × H)
- Weight: 51 lb
- Connections: 6 in., round, on top (vertical connection)
- Power supply: 120 V
- Drain: required, tube supplied
Like any HRV, it must be connected to a drain; the tube is supplied and installed with a loop. The unit mounts on the wall or hangs with chains. Allow 14 in. of free space in front of the door to remove the core and 2 3/8 in. above the electrical box.
Fantech recommends a fully dedicated installation, with its own ducts, to keep power consumption down. With a unit this frugal, it would be a shame to run a furnace blower to distribute the air.
Filters
Two washable electrostatic MERV 3 filters measuring 7 7/8 × 9 13/16 in. are supplied, to be washed in warm, soapy water. Fantech offers optional MERV 8 (428526) or MERV 13 (428548) filters, which are replaced: they cannot be washed.
The core and filters come out through the front door, held by two latches at the bottom of the unit. At the start of winter, check that the drain tube flows properly; we show you how at start-up.
Warranty
Fantech warrants the core for life, the fan motors for 7 years, and the electrical components and the damper motor for 5 years. The unit is designed for residential use only.
The HERO 150H-EC is certified in Section III of the HVI directory (number 2505258): its airflows and efficiencies are published and anyone can check them. On the financial assistance side, the rule changed on October 1, 2026: Rénoclimat no longer funds HRVs and ERVs, except for files already opened under the program's transition rules.
Installation by AirGreen in Greater Montreal
We start from the room-by-room ventilation calculation of the CSA F326 standard. If your home needs between 50 and 172 cfm, the HERO 150H-EC is an excellent candidate. We also show you the annual cost difference with the HERO 150H, with the figures to back it up.
At start-up, we set the unit with a manometer to the calculated airflow. We install in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Ask for a free quote at 514 316-2973 or sales@airgreen.ca.