Lifebreath 155 MAX HRV Air Exchanger | Montreal, Laval, Longueuil, South Shore and North Shore
Is it the right size for your home?
It delivers 138 cfm net, enough to ventilate 1,600 to 2,600 sq ft. Choose your home's living area.
It's the right size.
For a 1,500 to 2,500 sq ft home, about 105 cfm of air needs to be renewed continuously. This unit delivers 138 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$70.27
Electricity per year
Less than a 100 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 70% at 68 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 72 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
DXPL03DXPL03 digital wall control included
The DXPL03 digital control comes with the unit and is easy to program. It mounts on a wall in a central spot in the home (3-wire 20 ga cable, up to 100 ft).
DoorDoor balancing ports, adjustable dampers
The ports used to measure airflow are on the door, and balancing dampers sit in all airstreams. The high speed is selected by DIP switch (Hi 3 is the factory setting).
70%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 68 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505085Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−21 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 159 to 138 cfm. Most spec sheets show only the first number, precisely because it looks better.
72 WMeasured at the airflow it actually runs at
Its 75% at 0 °C is certified at 64 cfm, the continuous airflow of a typical home. At that setting it draws 72 W, or about 631 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
6 inWhat it needs on site
6 in ducts, top and side connection and a condensate drain. It weighs 71 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 159 cfm
- Net airflow at 0.4 in. w.g.
- 138 cfm
- SRE at 0 °C (64 cfm)
- 75%
- SRE at −25 °C (68 cfm)
- 70%
- ASE at 0 °C
- 82%
- Power draw
- 72 W
- Efficacy
- 0.9 cfm/W
- Type
- HRV
- Connection
- Top and side ports
- Duct collars
- 6 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 33.63 × 14.75 × 18.68 in
- Weight
- 71 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505085
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
- Spec sheet (French)
- Spec sheet (English)
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505085). Annual consumption calculated at 72 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
The 155 MAX 2019: 70% efficiency at −25 °C and control included
The Lifebreath 155 MAX 2019 is a heat recovery ventilator (HRV) that holds up well in deep cold. At −25 °C and 68 cfm, its sensible recovery efficiency is 70% (HVI directory, November 4, 2026 edition). The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at a minimum of 22 L/s. The 155 MAX 2019 therefore meets both thresholds. Among the Lifebreath HRVs we offer, only one beats that HVI rating at −25 °C: the RNC 205 PLUS, at 73%.
On its spec sheet, Lifebreath gives a net airflow of 170 cfm at 0.1 in. of static pressure, 159 cfm at 0.2 in., 148 cfm at 0.3 in. and 138 cfm at 0.4 in. That last figure is also the one the HVI directory publishes.
The “2019” in the name
It is not a year of manufacture. Lifebreath explains it in a note on its spec sheet: the “2019” refers to the unit's ENERGY STAR certification. The 155 MAX is on Natural Resources Canada's ENERGY STAR list, and Lifebreath states that the unit meets its requirements only in Canada.
Counter-flow HEX core
Lifebreath highlights its patented HEX core. This heat-conducting core moves the fresh air and the stale air in opposite directions, without mixing them, and the heat of the outgoing air passes to the incoming air. At 0 °C and the 64 cfm test airflow, HVI gives it 75% sensible recovery efficiency. It comes out of the unit easily for cleaning or service.
When it is very cold, defrost is handled by a recirculating damper, which Lifebreath calls intelligent: for the length of the cycle, indoor air flows through the core instead of outdoor air, and the frost melts.
DXPL03 control included
The DXPL03 digital wall control comes with the unit, and Lifebreath describes it as easy to program. It is surface mounted on a wall, in a central spot in the home, and connects to the unit with 3-wire, 20-gauge (minimum) wire, up to 100 ft long. So there is no control to add to your quote.
Balancing at the door
The airflow measuring ports are on the door, and each airstream has its own balancing damper. Lifebreath's installation manual provides, for the 155 MAX 2019, a chart that converts the reading taken at the door into airflow: no need to drill into the ducts to insert a Pitot tube. The high-speed setting is made with DIP switches on the circuit board, and Lifebreath sets Hi 3 at the factory.
Energy use
A common PSC motor turns the two centrifugal blowers, one per airstream, and offers several speeds. HVI measures 72 W at 64 cfm, its test point, or 0.9 cfm per watt; at −25 °C and 68 cfm, the draw rises to 92 W. Twelve months of continuous operation at 72 W come to about 631 kWh, or around $70 at Hydro-Québec Rate D (second tier, 11.142 ¢/kWh).
Installation
The cabinet, made of 22-gauge prepainted galvanized steel, measures 33.63 in. long, 14.75 in. deep and 18.68 in. high, and weighs 71 lb. Its insulation keeps condensation from beading on the walls. At the four corners, threaded inserts take the “S” hooks and straps supplied by Lifebreath. The 6 in. ducts connect to round collars. The drain is required and connects to two 1/2 in. (12 mm) OD fittings. In front of the door, keep 25 in. clear for service.
Filters
Two washable MERV 6 filters handle the stale air and the fresh air, one each. For finer filtration, Lifebreath offers a MERV 13 upgrade, part 65-195-6R.
Warranty
Lifebreath warrants the core for life, and the motors and parts for 5 years.
Which home it suits
The 155 MAX suits a home with room in the basement or a mechanical room, since a 33.63 in. long, 71 lb cabinet has to hang there. In a utility closet, we first check the dimensions and the door opening. As a replacement, its 6 in. round collars connect without a reducer to existing ductwork of the same diameter. If your home needs more than its 138 cfm net at 0.4 in., we will suggest a higher-capacity model.
Installation by AirGreen in Greater Montreal
Before recommending the 155 MAX, we assess the home's ventilation needs on site (bedrooms, bathrooms, kitchen, basement) and compare them with its 138 cfm net. Lifebreath calls for a heated space that is accessible for service, typically the mechanical room or a spot near the outside wall; in a basement, that second option keeps the ducts to the outdoor hoods short. Beyond 10 ft, Lifebreath recommends rigid duct that is sealed and insulated.
The straps screw to the joists with four screws and four washers, not supplied, and each washer must be wider than the strap's grommet eyelet; these adjustable straps are designed to limit noise and resonance. Outside, the fresh-air intake goes upstream of the stale-air outlet relative to the prevailing winds, away from a dryer vent, a gas meter or the driveway. If the unit is tied into the furnace return using the simplified method, Lifebreath requires the furnace blower to run continuously or be interlocked with the HRV. At start-up, we balance the two airflows at high speed, with the dampers first fully open and the range hood, dryer and bathroom fans off, until the air coming in equals the air going out.
Our team, under AirGreen's RBQ licence 5645-9605-01, serves Montreal, Laval, Longueuil, the North Shore and the South Shore.
Since October 1, 2026, Rénoclimat no longer funds HRV or ERV installations, except for a home already evaluated before the change whose post-work evaluation is done by March 31, 2027.
To get a free quote, call us at 514 316-2973 or send your plans to sales@airgreen.ca.