Is it the right size for your home?
It delivers 59 cfm net, enough to ventilate 700 to 1,100 sq ft. Choose your home's living area.
It's the right size.
For a condo or a home under 900 sq ft, about 37 cfm of air needs to be renewed continuously. This unit delivers 59 cfm net — enough for the house, with extra capacity to boost ventilation for the bathroom and kitchen.
Calculation: 0.35 air changes per hour over the living volume, with 9 ft ceilings. We set the exact airflow during our on-site assessment.
What it does, in numbers
$36.11
Electricity per year
Less than a 60 W light bulb
Bulbs left on day and night. Same calculation for every line: wattage × 8,760 h × 11.142 ¢/kWh.
Meets both thresholds of the Québec Construction Code (art. 9.36.3.9). At −25 °C and at least 22 L/s, the Code (art. 9.36.3.9, in force since April 17, 2025) requires 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere. This unit is rated at 65% at 51 cfm (HVI).
Airflow and efficiency at 0 °C and −25 °C: HVI directory, Section III. Cost: 37 W over 8,760 h at Hydro-Québec's Rate D second tier (11.142 ¢/kWh).
What you should know about this one
Published, verifiable facts, not brochure claims.
CompactLifebreath's smallest unit to date
Lifebreath presents it as its smallest unit to date, built for small homes and townhomes with tight space. It hangs from the supplied S hooks and straps, which attach to four threaded inserts at the cabinet corners.
MERV 13Washable MERV 6 filters, MERV 13 upgrade
It ships with washable MERV 6 filters in both the exhaust and supply airstreams. For finer filtration, Lifebreath offers a MERV 13 upgrade (part 65-195-6R).
65%What it still recovers at −25 °C
The only efficiency figure that matters for a Québec winter, and the one the Code uses. An efficiency quoted without its temperature means nothing; this one is measured at a test airflow of 51 cfm.
DamperIt defrosts with indoor air
In cold weather, a motorized damper closes the outdoor air intake and recirculates indoor air through the core to thaw it. During the cycle, no outdoor air comes in through the unit.
HRVIt recovers heat, not moisture
Excess moisture leaves the house. In Québec, that's the right choice in most cases: in winter, a house almost always has too much humidity, not too little.
2505248Its HVI certification number
Listed in Section III of the Home Ventilating Institute's certified products directory. Anyone can check it.
−11 cfmWhat the ducts cost it
Between a nearly unrestricted test bench (0.2 in) and a real duct system (0.4 in), it drops from 70 to 59 cfm. Most spec sheets show only the first number, precisely because it looks better.
37 WMeasured at the airflow it actually runs at
Its 63% at 0 °C is certified at 47 cfm, the continuous airflow of a typical home. At that setting it draws 37 W, or about 324 kWh a year.
LifetimeThe core warranty
The core does the work and is the most expensive part to replace. Motors and parts: 5 years.
4 inWhat it needs on site
4 in ducts, top connection and a condensate drain. It weighs 35 lb, and it needs enough clearance to slide the core out for cleaning.
What it needs on site
In a condo with no floor drain, or with little ceiling clearance, we usually look at a side-port model instead. Our estimator checks the location, the drain and the duct route before ordering.
Complete spec sheetData and cited sources
- Net airflow at 0.2 in. w.g.
- 70 cfm
- Net airflow at 0.4 in. w.g.
- 59 cfm
- SRE at 0 °C (47 cfm)
- 63%
- SRE at −25 °C (51 cfm)
- 65%
- ASE at 0 °C
- 68%
- Power draw
- 37 W
- Efficacy
- 1.3 cfm/W
- Type
- HRV
- Connection
- Top ports
- Duct collars
- 4 in
- Condensate drain
- Required
- Defrost cycle
- Recirculation (motorized damper)
- Filters
- 2 washable MERV 6 filters (exhaust and supply); MERV 13 upgrade (65-195-6R)
- Dimensions (L × D × H)
- 18.75 × 17.88 × 19.25 in
- Weight
- 35 lb
- Power supply
- 120 V
- HVI certification (Section III)
- 2505248
- Warranty — core
- Lifetime
- Warranty — motors
- 5 years
- Warranty — parts
- 5 years
Net airflow, efficiency at 0 °C and −25 °C, and power draw: Home Ventilating Institute certified products directory, Section III (HVID 2505248). Annual consumption calculated at 37 W running continuously for 8,760 h, at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The next model down and up
Talk to an HVAC technician before you choose
We assess your needs on site, check the location and the drain, and give you an installed price. Balancing is measured at commissioning, not estimated.
Lifebreath RNC4-TPD: a compact HRV for tight spaces
At AirGreen, we install the Lifebreath RNC4-TPD air exchanger, which Lifebreath presents on its spec sheet as its smallest unit to date. The manufacturer considers this heat recovery ventilator (HRV) ideal for a small home or a townhome where room is limited. It weighs 35 lb (16 kg), and none of its three dimensions exceeds 19 1/4 in. (489 mm).
This compact HRV renews your home's air and recovers part of the heat held in the stale air before sending it outside.
Heat Recovery Core
Its thermally conductive counter-flow hex core exchanges heat between the outgoing and the incoming air. It is easily removed for cleaning or service.
Motors and Speeds
Each airstream has its own motorized impeller with several speeds. This design lets the installer match the airflow to your home's needs. Low speed is fixed; high speed is set to one of three choices on the circuit board's DIP switches (Hi3 from the factory).
Filtration
The stale air and the fresh air each pass through a washable MERV 6 filter. Lifebreath also offers MERV 13 filters (part 65-195-6R), which capture finer particles.
Mounting and Clearance
The cabinet has a threaded insert at each of its four corners: the S hooks and straps supplied with the unit attach there and hang it from the basement floor joists. Lifebreath recommends leaving at least 25 in. (635 mm) of clear space in front of the unit to open and close the door.
Recirculating Damper Defrost
The RNC4-TPD uses an intelligent recirculating damper defrost system, which keeps frost from building up in the unit in cold weather. Since a defrost cycle can produce condensation, the unit connects to a drain.
Cabinet, Collars and Drain
The cabinet is made of corrosion-resistant 22-gauge prepainted galvanized steel, and it is insulated to prevent condensation on its outer walls. The 4 in. (102 mm) round collars are on top of the unit. Balancing dampers are built into both airstreams, and the balancing ports are on the unit. Two drain spouts, 12 mm (1/2 in.) OD, carry the condensation away.
Controls and Timers
The wall control is optional. It connects to the unit with 3-wire, 20-gauge (minimum) cable, up to 100 ft long. Lifebreath's 99-DET01 and 99-DET02 timers switch the unit to high speed for 20, 40 or 60 minutes. The 99-DET02 timer pairs wirelessly with the main control, which simplifies installation; Lifebreath gives an estimated range of 40 ft (12 m) with no obstructions, and the 99-RX02 repeater extends it.
HVI-Certified Performance
The RNC4-TPD is listed in Section III of the HVI directory under number 2505248. At 0°C and 47 cfm, it is rated at 63% sensible recovery efficiency, drawing 37 W. Notably, this efficiency does not drop in deep cold: at −25°C and 51 cfm, the same directory (November 4, 2026 edition) gives it 65%. The Québec Construction Code (art. 9.36.3.9) requires at least 55% where there are fewer than 6,000 heating degree-days and 60% elsewhere, at no less than 22 L/s. It therefore meets both thresholds. Its net airflow reaches 59 cfm at 0.4 in. of static pressure, and 70 cfm at 0.2 in.
Warranty
Lifebreath covers the HRV core for life and replacement parts for 5 years.
Installation by AirGreen
Before recommending the RNC4-TPD, we assess your home's ventilation needs on site, from the bedrooms and bathrooms to the kitchen and basement. If those needs exceed what its 59 cfm net delivers, we offer you a larger Lifebreath model.
On this model, Lifebreath calls for fitting the drain spouts with the foam gasket alone and tightening their nuts by hand only; both spouts then connect to 1/2 in. drain hose. The unit plugs into a standard grounded 120 V outlet, with no extension cord, and Lifebreath recommends a separate 15 A circuit. At start-up, we balance its two airflows on high speed, with the furnace blower on if there is one, as Lifebreath requires.
For a free quote, call us at 514 316-2973 or write to sales@airgreen.ca: we will call you back. Our team, under AirGreen's RBQ licence 5645-9605-01, installs the RNC4-TPD in Montreal, Laval, Longueuil, the North Shore and the South Shore.