COMFORTMAKER EAM5X37M21A Evaporator A-Coil | 3 Tons

In stock

The Comfortmaker EAM5X37M21A 3-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEAM5X37M21A

3 tons36,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217953748
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEAM5X37M21A
ManufacturerComfortmaker
Size3 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V24*K*AAA

EAM5X37M21A: the smallest coil in the series, made for the electrically heated bungalow

Across Greater Montreal, thousands of bungalows and townhouses still have the electric furnace they got in the seventies or eighties, with old baseboard heaters or window air conditioners for the summer. The Comfortmaker EAM5X37M21A evaporator coil is made for that kind of home. It is a cased A-coil rated at 3 tons (36,000 BTU/h nominal), 21 in wide, and it runs on R-454B refrigerant.

AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore. This page explains what the model does, which outdoor unit it works with, what you should measure at home before buying, and how it differs from the seven other coils in the EAM5X range.

What an evaporator coil actually does

Think of it as the heat exchanger on the indoor side. It sits in the furnace plenum, right in the path of the air. When the outdoor unit sends cold refrigerant through its tubes, the house air passing through loses its heat and a good share of its moisture. The water that condenses runs into the pan and then to the drain.

With a heat pump outside, the cycle reverses in winter. The coil becomes the surface that releases the heat collected outdoors. The same equipment therefore works in both seasons, and the air distribution in your home, meaning your existing ductwork, stays the same.

A 3-ton size for small and medium-sized homes

The 3-ton size is the most modest in the series. It suits a home with reasonably sized rooms and walls that have been insulated over the years of renovations. We never pick the capacity by eye: a visit to your home, a calculation of the house's needs and a look at your electricity bill guide the decision. An oversized coil does not make the house more comfortable. It cools quickly, shuts off quickly and dehumidifies poorly.

If the calculation points to a larger capacity, the range offers models of 3.5 tons, 4 tons and 5 tons. The comparison section below summarizes the differences.

The certified match: three published outdoor units

A coil on its own has no efficiency rating. Complete systems are what get certified, with an AHRI number that ties one coil to one specific outdoor unit. Here are the three published matches for the EAM5X37M21A:

  • Q5H9V24*K*AAA: AHRI 217953748, SEER2 16.0 and HSPF2 9.5, with 23,000 BTU/h in cooling and 24,800 BTU/h in heating at 47 °F;
  • N5H9V24*K*AAA: AHRI 217953741, same ratings and same capacities as the previous one;
  • C5H8T24*K*AAA: AHRI 216364458, SEER2 15.5 and HSPF2 7.8, with 22,400 BTU/h in cooling and 24,600 BTU/h in heating at 47 °F.

The AHRI number is the item to compare from one quote to the next. Two contractors who talk about a "3-ton system" are not necessarily selling the same thing, while the number leaves no ambiguity.

Turning an electric furnace into an "add-on" heat pump

This is the most common scenario with this model. We keep the furnace, its blower and its filters, then add the coil above it and an outdoor unit in the yard. In summer, the house is air conditioned. In winter, the heat pump supplies most of the heat, and the furnace only starts below an outdoor temperature threshold that we set with you.

An electric furnace converts each kilowatt-hour into an equivalent amount of heat. A heat pump moves heat instead of making it, which is why the bill goes down when a home switches to this type of system. The colder it gets outside, the more the gap narrows, and that is why the furnace stays useful for the coldest days.

Dimensions, weight and connections: what we check on site

  • cabinet 21 in wide by 29-3/4 in high, net weight 79.4 lb;
  • 3/4 in suction connection, the smallest in the series;
  • possible positions: upflow, downflow or horizontal;
  • two condensate pans in fibreglass-reinforced thermoset polyester, one for vertical installation and one for horizontal installation, both sloped toward the drain;
  • TXV metering device, which doses the refrigerant according to the load;
  • factory-mounted A2L leak sensor and harness, with the dissipation board, enclosure and power harness supplied in the parts box.

The 21 in width must match that of your furnace. If it does not, we build an insulated transition on site rather than force a compromise.

Choosing between the EAM5X37M21A and its seven neighbours

The range has eight coils from the same family, all on R-454B, all with a TXV metering device and a cabinet. The differences that matter for your decision:

  • EAM5X42M21A and EAM5X43M21A: 3.5 tons, same 21 in width, matched with the B5H3V36*K*AAA unit. One step up in capacity, without changing the furnace.
  • EAM5X42M24A: 3.5 tons in a 24-1/2 in cabinet, for a wider furnace.
  • EAM5X48M21A and EAM5X48M24A: 4 tons, in 21 in or 24-1/2 in.
  • EAM5X60M24A and EAM5X61M21A: 5 tons, in 24-1/2 in or 21 in.

The EAM5X37M21A is therefore the logical choice when the furnace measures 21 in and the load calculation stays in the modest range. It is also the only one in this family with a 3/4 in suction connection.

What this coil does not do

It does not pair with just any old air conditioner. It runs on R-454B and must be installed, at the same time, with an outdoor unit designed for the same refrigerant. Keeping the old outdoor unit is therefore generally not possible. Nor does it improve airflow on its own: the furnace blower must already be able to move the air the system requires.

Frequently asked questions

Can it heat? Yes, if it is connected to a heat pump. With a central air conditioner, it only provides cooling.

Will my furnace still be used? Yes. It provides backup heat at the lowest temperatures.

What happens if the width is different? We measure and build an insulated transition if needed.

What our installation includes

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. For this coil, the typical process is as follows:

  • measuring the furnace and checking the blower and the electrical panel;
  • installing the coil in the plenum and sealing the connections;
  • setting up the outdoor unit, brazing the piping, nitrogen leak test and vacuum;
  • connecting the condensate drain and the thermostat;
  • start-up, airflow adjustment, then an explanation of how the system works, in your home.

LogisVert rebate

The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. Eligibility is judged on the complete system and not on the coil alone, and the amount depends on the installation date and your situation. We check the official list at the time of the quote and put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EAM5X37M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Certified systemMatched with the Q5H9V24*K*AAA, the system carries AHRI 217953748.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEAM5X37M21A
TypeCased evaporator coil
LineEAM5X
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Suction connection3/4 in
Dimensions W × H × D21 × 29-3/4 in
Net weight79.4 lb
Matched outdoor unitQ5H9V24*K*AAA, N5H9V24*K*AAA, C5H8T24*K*AAA
System AHRI number217953748, 217953741, 216364458
System SEER2 / HSPF216.0 / 9.5
Model numberEAM5X37M21A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.