COMFORTMAKER EAM5X61M21A Evaporator A-Coil | 5 Tons

In stock

The Comfortmaker EAM5X61M21A 5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEAM5X61M21A

5 tons60,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217954430
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEAM5X61M21A
ManufacturerComfortmaker
Size5 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V48*K*AAA

Five tons in a narrow cabinet: the Comfortmaker EAM5X61M21A in five questions

The Comfortmaker EAM5X61M21A evaporator coil often puzzles people on first reading: five tons, or 60,000 BTU/h nominal, but only 21 in wide. It is a cased A-coil on R-454B, measuring 21 in wide by 35 in high and weighing 89 lb net. Rather than a linear presentation, here are the five questions homeowners ask us most often about it.

AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Question one: why a narrow cabinet for such a large capacity?

Because a coil's capacity is not read from its width alone. Here, the cabinet gains in height, with its 35 in, rather than in width. The result: it fits on a 21 in furnace, which is common in the older homes of Greater Montreal, while offering the capacity of the upper end of the range.

The trade-off is vertical clearance. We always measure the distance to the joists before ordering.

Question two: which outdoor unit does it work with?

Two certified systems are published:

  • Q5H9V48*K*AAA, AHRI 217954430: cooling of 45,000 BTU/h, heating of 49,000 BTU/h at 47 °F, SEER2 15.5, HSPF2 9.0;
  • N5H9V48*K*AAA, AHRI 217954425: same capacities, same ratings.

These ratings are those of the complete system, not of the coil. The AHRI number is the reference to write down on your quote.

Question three: what is the difference with the EAM5X60M24A?

The two coils show the same nominal capacity, the same published outdoor units and the same refrigerant. The difference lies in the width, 21 in here against 24-1/2 in for the EAM5X60M24A, as well as in the AHRI numbers and the certified ratings. If your furnace is narrow, this model is the one; if it is wide, the other fits more directly.

When in doubt, we measure the cabinet and recommend the one that avoids an unnecessary transition.

Question four: what if five tons is too much?

That is a good question, and we ask it before you do. Excess capacity produces short cycles and leaves the air humid. So we do the house's load calculation before proposing this size. If the result comes out lower, the range offers alternatives in 21 in: the EAM5X48M21A (4 tons), the EAM5X42M21A and EAM5X43M21A (3.5 tons) and the EAM5X37M21A (3 tons). For a wider furnace, there are also the EAM5X42M24A and EAM5X48M24A.

Question five: what should you check before signing?

  • The width of the furnace: 21 in, or an insulated transition built on site.
  • The height available above the furnace, for a 35 in cabinet.
  • The blower's ability to circulate the air of a system this size.
  • The refrigerant: R-454B for the coil as for the outdoor unit.
  • The AHRI number of the complete system.

An example: the Montreal plex with a narrow furnace

In a Montreal duplex or triplex, a unit's furnace often occupies a corner of the basement, with a width limited by the original cabinet. The owner wants to cool a large two-level unit. With a 21 in cabinet, the coil goes in without moving the furnace; what needs checking is the height under the joists and the path of the plenum. Once those measurements are confirmed, installation is simple and is done without touching the air distribution.

On the South Shore, in Longueuil or in Laval, the scenario is similar: an enlarged bungalow, an added storey, an original furnace that stays compact. The same model settles the width question.

What we do not promise

We do not claim that five tons suit every home, or that the rating number alone makes the quality of a system. We promise a visit, a calculation, a written quote that names the coil, the outdoor unit and the AHRI number, and an installation done by the book. The rest depends on the house, and we prefer to tell you before you sign rather than after.

The manufacturing features

  • 7/8 in suction connection;
  • TXV metering device;
  • upflow, downflow or horizontal installation;
  • two sloped condensate pans, vertical and horizontal, in fibreglass-reinforced thermoset polyester;
  • factory-mounted A2L leak sensor and harness, with the dissipation board, enclosure and power harness delivered in the parts box.

A warranty that depends on a formality

The manufacturer covers parts for ten years, but only if registration is done within 90 days of installation; otherwise the coverage is five years. We do it for you, at start-up, so that this protection does not depend on an oversight.

What the coil brings day to day

It replaces window air conditioners with a single outdoor unit and air distribution through the existing ducts. With a heat pump, it also heats, and the furnace stays in place as backup. The house is drier in summer, more even from room to room, and you manage everything with a single thermostat.

After installation: three simple habits

First, check the filter at regular intervals, especially after renovation work that stirs up dust. Second, keep the outdoor unit clear of snow, leaves and objects stored against it. Third, watch the condensate drain during the first weeks of warm weather: if the water flows normally, all is well. These steps take a few minutes and preserve both the comfort and the equipment.

How the installation goes

We measure the furnace, check the blower and the electrical panel, install the coil in the plenum and seal the connections. The outdoor unit is set on a pad or a bracket, the piping is brazed, tested with nitrogen and pulled under vacuum. The drain and the thermostat are connected, the airflow is adjusted, then we explain the whole system to you. AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01.

LogisVert rebate

The matched Comfortmaker system is on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it on the official list and prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EAM5X61M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V48*K*AAA outdoor unit
Certified systemMatched with the Q5H9V48*K*AAA, the system carries AHRI 217954430.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEAM5X61M21A
TypeCased evaporator coil
LineEAM5X
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Suction connection7/8 in
Dimensions W × H × D21 × 35 in
Net weight89 lb
Matched outdoor unitQ5H9V48*K*AAA, N5H9V48*K*AAA
System AHRI number217954430, 217954425
System SEER2 / HSPF215.5 / 9.0
Model numberEAM5X61M21A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.