COMFORTMAKER EAM5X42M24A Evaporator A-Coil | 3.5 Tons
The Comfortmaker EAM5X42M24A 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Comfortmaker outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEAM5X42M24A
514 316-2973 · sales@airgreen.ca
Quick facts
Comfortmaker EAM5X42M24A: the 3.5-ton coil for wide 24-1/2 in furnaces
Not all furnaces look alike. Some have a narrow cabinet, while others, newer or sturdier, measure 24-1/2 in wide. If yours belongs to the second category and your home needs a 3.5-ton system (42,000 BTU/h nominal), the Comfortmaker EAM5X42M24A evaporator coil is designed to fit on it without improvising.
It is a cased A-coil on R-454B refrigerant that fits the plenum of a furnace or blower cabinet. AirGreen installs it in Montreal, Laval, Longueuil, the North Shore and the South Shore.
Why width matters so much
The coil slides into the plenum, above the furnace. If its width does not match the cabinet, a transition piece has to be built, which adds time and more joints to seal. With a 24-1/2 in cabinet on a furnace of the same size, the transition is direct: the air crosses the whole surface of the coil, with no detour, and the seal relies on a simpler assembly.
The flip side: if your furnace is narrower, this model is not the right one. In that case, the EAM5X42M21A offers the same capacity in 21 in.
What the data sheet says
- Nominal capacity: 3.5 tons, or 42,000 BTU/h.
- Cabinet: 24-1/2 in wide by 29-3/4 in high.
- Net weight: 76.3 lb.
- Suction connection: 7/8 in.
- Metering device: TXV.
- Positions: upflow, downflow or horizontal.
- Sloped condensate pans in fibreglass-reinforced thermoset polyester, one for each orientation.
- Safety: factory-installed A2L leak sensor and harness, with the rest of the detection hardware supplied in the parts box.
- Manufacturer parts warranty: ten years with registration within 90 days of installation, five years without registration.
And the outdoor unit?
For this model, the coil connects to a Comfortmaker outdoor unit of the same capacity, always on R-454B. In the ENERGY STAR match lists we consulted, none appears for the EAM5X42M24A. That does not mean it is unusable: it means that, before ordering, we confirm which combination is offered and which AHRI number goes with it.
If certified efficiency or a rebate weighs heavily in your decision, this is a point to settle first. In the same spirit, a system matched to a 21 in coil, such as the EAM5X42M21A, has published matches that are easier to read.
Cooling without changing the ducts
The main appeal of this coil is that it makes use of the existing air distribution. A single outdoor unit replaces the window air conditioners, one thermostat controls everything, and cool air circulates to every room through the same vents. The condensation is collected in the pan and carried to the drain, which dries the air during humid periods.
And heating, with a heat pump
If the outdoor unit is a heat pump, the coil also works in winter. The system supplies most of the heat as long as the cold remains manageable for it; the furnace starts beyond a temperature threshold that we set together. The energy bill benefits from this sharing of the work. With an air conditioner alone, the furnace keeps heating as before.
A common scenario on the North Shore
A North Shore house built in the nineties, with a wide furnace in the basement and a central air conditioner that has had its day. The owner does not want to touch the floor or open up new walls. The 24-1/2 in coil goes on the existing furnace, the outdoor unit replaces the old one in the yard, and the house keeps its air vents and its thermostat in a familiar spot.
In Montreal, in a duplex or triplex where each unit has its own furnace, the reasoning is the same, but the plenum is sometimes tighter: the height available above the furnace must be measured carefully before ordering.
Height and clearance: do not forget them
The cabinet is 29-3/4 in high. In a basement with a low ceiling, that dimension adds to the height of the furnace and can decide everything. We measure the clearance up to the joists, check access for servicing the filter and the pan, then confirm the installation position, upflow, downflow or horizontal, according to the layout of the mechanical room.
Upkeep after installation
An air conditioning system lasts longer when you look after it: clean filter, clear drain, outdoor unit free of leaves and snow. We show you where the points to watch are and how often to check the filter. The coil's sloped pan is designed to drain water, but a blocked drain remains the most ordinary cause of water damage; better to know that before summer.
How this model compares with the rest of the series
- Same capacity, narrower: EAM5X42M21A and EAM5X43M21A, in 21 in, with the published B5H3V36*K*AAA unit.
- Same width, higher capacity: EAM5X48M24A, 4 tons.
- Lower capacity: EAM5X37M21A, 3 tons in 21 in.
- Higher capacity: EAM5X60M24A, 5 tons in 24-1/2 in.
The EAM5X42M24A is the only one in the range to combine 3.5 tons and a 24-1/2 in width.
How we work
We start by measuring the furnace, assessing the blower and inspecting the electrical panel. The coil is installed in the plenum and its connections are sealed. The outdoor unit goes on a pad or a bracket; the piping is brazed, tested with nitrogen and then put under vacuum. Finally, we connect the drain and the thermostat, adjust the airflow and go over how the system works with you. AirGreen, a Montreal heating and cooling company founded more than fifteen years ago, carries out this work under RBQ licence 5645-9605-01.
Questions to ask before signing
- What AHRI number appears on the quote, for the complete system?
- Does the width of the furnace match 24-1/2 in?
- Does the blower deliver the required airflow?
- Is the outdoor unit designed for R-454B?
LogisVert rebate
The matched Comfortmaker system must appear on Hydro-Québec's list of eligible heat pumps to qualify for the incentive. The amount depends on the installation date and your situation. We check the official list at the quote stage and prepare the application with you, with no surprises.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The EAM5X42M24A sits in the plenum of a furnace or air handler. Connected to a matching Comfortmaker outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Comfortmaker outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.