COMFORTMAKER EAM5X48M21A Evaporator A-Coil | 4 Tons

In stock

The Comfortmaker EAM5X48M21A 4-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEAM5X48M21A

4 tons48,000 BTU/h nominal
21 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217954402
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEAM5X48M21A
ManufacturerComfortmaker
Size4 tons
Width21 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V48*K*AAA

EAM5X48M21A coil: 4 tons of capacity in a 21 in cabinet, for the large home with a furnace

In some homes, winter is won or lost in the basement: a gas or electric furnace working hard from November to March, many rooms, one more storey than average. For these homes, switching to a heat pump while keeping the furnace as backup is a sensible way to reduce reliance on baseline heating. The Comfortmaker EAM5X48M21A is the coil that makes this setup possible in a 21 in cabinet.

It is a cased A-coil of 4 tons (48,000 BTU/h nominal), running on R-454B. We install it in homes in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Thinking about capacity starting from winter

In Quebec, a heat pump is judged on its heating capacity as much as on its cooling capacity. The two published matches for this coil show 43,500 BTU/h in cooling and 49,000 BTU/h in heating at 47 °F. This gap in favour of heating is useful in a large home: it extends the part of the cold season in which the heat pump is enough on its own.

Beyond that, the furnace takes over. That is the principle of the "add-on" setup: a heat pump that handles the mild and moderate days, a furnace that holds the cold nights, and a switchover threshold set with you so that the transition goes unnoticed.

The two certified matches

  • Q5H9V48*K*AAA: AHRI 217954402, SEER2 15.2, HSPF2 9.0;
  • N5H9V48*K*AAA: AHRI 217954397, SEER2 15.2, HSPF2 9.0.

The published capacities are identical for both. The choice between the two is therefore made on the location of the outdoor unit, availability and your installer's preference, more than on the advertised performance.

The 21 in cabinet and its companions

A cabinet 21 in wide and 29-3/4 in high, weighing 77.2 lb net, is a reasonable size for a coil of this capacity. Its suction connection is 7/8 in. It accepts upflow, downflow or horizontal installation, and it is equipped with two sloped pans in fibreglass-reinforced polyester so that the condensation water drains equally well in either direction.

The metering device is a TXV. The A2L leak sensor and its harness are factory-mounted; the rest of the detection kit, that is, the dissipation board, the enclosure and the power harness, ships separately and is connected during installation.

What if my furnace is wider?

If your cabinet measures 24-1/2 in, the same capacity exists under the code EAM5X48M24A. We measure before ordering, and when the difference is small, an insulated transition built on site settles the matter without changing the model.

4 tons or something else? Reference points in the range

  • EAM5X37M21A: 3 tons, 21 in, for a more modest home.
  • EAM5X42M21A and EAM5X43M21A: 3.5 tons, 21 in, with the B5H3V36*K*AAA unit.
  • EAM5X42M24A: 3.5 tons, 24-1/2 in.
  • EAM5X48M24A: 4 tons, 24-1/2 in.
  • EAM5X60M24A and EAM5X61M21A: 5 tons, with the same Q5H9V48*K*AAA outdoor unit as this model.

Here is an interesting point: the 4-ton and the 5-ton share the same family of outdoor units. The final capacity therefore depends in part on the coil chosen, which is one more reason to have the load calculation validated before placing the order.

What to keep in mind before signing

  • The coil has no efficiency rating of its own; ratings belong to the system.
  • It requires an R-454B outdoor unit, installed at the same time.
  • The furnace blower must deliver the system's airflow; a 4-ton calls for good airflow.
  • The existing ducts must be able to carry that air without excessive noise.

A typical January day, step by step

In the morning, it is mild for the season and the heat pump is enough: the furnace stays off, and the blower circulates the air warmed by the coil. In the afternoon, the wind picks up and the outdoor temperature drops. The system keeps running as long as it stays above the threshold we programmed. At night, when the cold becomes severe, the furnace kicks in as well, without anyone having to touch the thermostat.

This automatic sharing is the real comfort of this setup: you do not choose between two appliances, the thermostat takes care of it.

For North Shore homeowners, where the temperature swings between day and night are often marked in spring and fall, this automatic management also avoids heating needlessly with the backup when a heat pump would be enough.

Airflow, a detail that matters with 4 tons

The greater the capacity, the greater the amount of air that has to pass through the coil. If the ducts are narrow, if the return air is pinched or if the filter is too restrictive, the blower struggles, the noise increases and the heat exchange suffers. That is why we inspect the return, the main branches and the filter during the visit. In a Laval or Longueuil house built at a time when little air conditioning was installed, we sometimes recommend a simple adjustment of the grilles or a more suitable filter.

These checks are not a luxury: they determine whether the system will deliver the comfort shown on the data sheet.

The manufacturer's warranty

On parts, Comfortmaker grants a limited ten-year warranty when the unit is registered within 90 days of installation. Without registration, the coverage is five years. We do the registration for you.

How the installation unfolds

The visit begins with measuring the furnace and checking the electrical service. Then come installing the coil in the plenum, sealing the connections, setting up the outdoor unit, brazing the piping, the nitrogen test, the vacuum, connecting the drain and the thermostat, then adjusting the airflow. AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, working under RBQ licence 5645-9605-01.

LogisVert rebate

The matched Comfortmaker system is on Hydro-Québec's list of eligible heat pumps. The amount varies according to the installation date and your situation. We check it on the official list at the quote and prepare the application with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EAM5X48M21A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V48*K*AAA outdoor unit
Certified systemMatched with the Q5H9V48*K*AAA, the system carries AHRI 217954402.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEAM5X48M21A
TypeCased evaporator coil
LineEAM5X
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Suction connection7/8 in
Dimensions W × H × D21 × 29-3/4 in
Net weight77.2 lb
Matched outdoor unitQ5H9V48*K*AAA, N5H9V48*K*AAA
System AHRI number217954402, 217954397
System SEER2 / HSPF215.2 / 9.0
Model numberEAM5X48M21A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.