COMFORTMAKER ESH5X30M12A Horizontal Evaporator Coil | 2.5 Tons

In stock

The Comfortmaker ESH5X30M12A 2.5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker B5H3V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberESH5X30M12A

2.5 tons30,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 218406955
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberESH5X30M12A
ManufacturerComfortmaker
Size2.5 tons
RefrigerantR-454B
MeteringTXV
Outdoor unitB5H3V24*K*AAA

The ESH5X30M12A, a 2.5-ton Comfortmaker coil that bridges the gap between small and medium

Between a home that gets by with 2 tons and another that needs 3, there are a lot of Greater Montreal homes: suburban two-storeys, enlarged bungalows, renovated semi-detached houses. The Comfortmaker ESH5X30M12A evaporator coil was designed for them. It is a 2.5-ton cased coil (30,000 BTU/h nominal), running on R-454B refrigerant, that installs on a furnace or a blower cabinet. Our crews work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Why a half size exists

Central sizes advance in half-ton steps. That may seem minor, but in a home right at the limit, that step makes the difference between a system that follows demand and one that struggles or shuts off too soon. The ESH5X30M12A exists for cases where the calculated load falls in that in-between.

Our method is simple: we calculate the home's load, we look at the existing furnace, then we choose the size. Never the other way around.

The base match: B5H3V24*K*AAA

An interesting fact: this 2.5-ton coil shares its main outdoor unit with the 2-ton model, the B5H3V24*K*AAA. It is the coil that changes, not the unit outside, and the published ratings change slightly with it. Comfortmaker lists two certified systems:

  • B5H3V24*K*AAA outdoor unit, AHRI 218406955, cooling 22,400 BTU/h, heating 25,600 BTU/h at 47 °F, SEER2 19.5, HSPF2 9.5;
  • C5H8T24*K*AAA outdoor unit, AHRI 216368117, cooling 23,200 BTU/h, heating 25,200 BTU/h at 47 °F, SEER2 16.5, HSPF2 7.8;

Keep in mind that the AHRI number belongs to the coil-plus-unit pair. It is used to compare two quotes and to validate a grant application.

Four seasons with this coil

Spring. The first mild days: the system heats or cools without the furnace waking up. This is the period when a heat pump shines.

Summer. The coil captures heat and moisture from the air passing through it; the condensation runs off through the sloped pan to the drain.

Fall. The same logic as spring, with the bonus of mild heating from the heat pump coming back.

Winter. When the outdoor temperature falls below the threshold we set with you, the furnace takes over as backup. You keep the comfort of the deep cold, without abandoning what already works in your home.

How this model compares with the others in the ESH5X series

All models in the series are horizontal and cased, with a TXV and R-454B. Here is what sets them apart in practice:

  • ESH5X24M12A, 2 tons: same B5H3V24*K*AAA outdoor unit, better suited to the smallest homes;
  • ESH5X30M12A, 2.5 tons: the model we are discussing here;
  • ESH5X36M12A, 3 tons: moves to the B5H0V36*K*AAA unit;
  • ESH5X42M12A, 3.5 tons: same B5H0V36*K*AAA unit as the 3-ton;
  • ESH5X48M12A, 4 tons, and ESH5X60M12A, 5 tons: B5H0V48*K*AAA unit.

If you are torn between the 2-ton and this one, the calculated load decides. If you are torn between this one and the 3-ton, we also look at the furnace and the blower, because the outdoor unit changes at that point.

A horizontal, bidirectional form

The manufacturer publishes a horizontal position with bidirectional airflow. In practice, this coil fits in a crawl space, an attic or a basement ceiling, wherever the furnace lies on its side. The sloped, corrosion-resistant drain pan sits under the exchanger; the drain diameter is not published, so we check it at the visit.

The TXV metering device adjusts the refrigerant flow to the load. The manufacturer also provides a factory-installed refrigerant leak dissipation system, noted on its page.

What to know about R-454B

This refrigerant requires a consistent match: the coil and the outdoor unit are installed together, with the same fluid. It is therefore generally not possible to keep an old air conditioner and connect this coil to it. We install the complete system, from the brazed piping to commissioning.

Three ways to tell whether 2.5 tons suits you

First clue: your old air conditioner, if there was one, always seemed a little tight in the middle of a heat wave, but never truly overwhelmed. Second clue: some rooms, often upstairs or on the south side, stay warmer than the rest. Third clue: the house has been enlarged or better insulated since the original installation, which shifts the load without anyone thinking about it.

These clues do not replace a calculation, but they steer the conversation. We note them at the visit, then compare them with the measurements taken on site. If the calculation points to another size, we tell you frankly.

What the heat pump adds to the furnace

An electric furnace turns each kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside: at mild temperatures, it delivers two to three times more heat than the electricity it uses. That efficiency drops with the cold, which is why it makes sense to keep the furnace as backup.

In summer, the same circuit replaces window air conditioners. One unit outside, cool air distributed to every room through the existing ducts, and a single thermostat for both seasons.

A word about Comfortmaker

Comfortmaker is a brand of International Comfort Products (ICP), a subsidiary of Carrier. Its R-454B evaporator coils go with its central heat pumps and air conditioners, installed on a furnace or a blower cabinet. For the homeowner, that means parts that are compatible with each other, a documented match and an AHRI number for each system.

How the installation unfolds

  • Visit: measuring the furnace, checking the blower and the electrical service.
  • Coil installation in the plenum; an insulated transition is built on site if the widths differ.
  • Outdoor unit installation, brazing, nitrogen test, evacuation.
  • Drain, thermostat, then airflow adjustment.
  • Explanation of how everything works, warranty registration.

AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, carries out this work under RBQ licence 5645-9605-01.

What to check before choosing

  • The coil has no efficiency rating of its own: those belong to the matched system.
  • The furnace blower must deliver the system's airflow.
  • The manufacturer's limited warranty is 10 years on parts with registration within 90 days of installation, 5 years without registration.
  • Comfortmaker states that the ratings are published with a furnace and a wall control.

LogisVert grant

The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you. Eligibility is judged on the complete system, not on the coil alone.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The ESH5X30M12A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H3V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker B5H3V24*K*AAA outdoor unit
Certified systemMatched with the B5H3V24*K*AAA, the system carries AHRI 218406955.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelESH5X30M12A
TypeCased evaporator coil
LineESH5X
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Matched outdoor unitB5H3V24*K*AAA, C5H8T24*K*AAA
System AHRI number218406955, 216368117
System SEER2 / HSPF219.5 / 9.5
Model numberESH5X30M12A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.