COMFORTMAKER ESH5X42M12A Horizontal Evaporator Coil | 3.5 Tons
The Comfortmaker ESH5X42M12A 3.5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker B5H0V36*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberESH5X42M12A
514 316-2973 · sales@airgreen.ca
Quick facts
Reading a quote built around the ESH5X42M12A, the 3.5-ton Comfortmaker coil
When a home is spacious, central heat pump quotes rarely look alike. One talks about "3.5 tons", another about "42,000 BTU/h", a third settles for a model number. This text helps you connect it all around one specific part: the Comfortmaker ESH5X42M12A evaporator coil, a horizontal cased model, rated at 3.5 tons (42,000 BTU/h nominal) and running on R-454B refrigerant. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Decoding the model name
In ESH5X42M12A, the number 42 refers to the nominal size of 42,000 BTU/h, or 3.5 tons. The range is called ESH5X. The rest of the reference identifies the configuration published by the manufacturer. We copy it as is onto our quotes, so you can check every letter with any other supplier.
The AHRI number: the key to any comparison
The coil has no efficiency rating on its own. The ratings belong to the matched system, which the AHRI number links to a specific outdoor unit. For the ESH5X42M12A, Comfortmaker publishes two systems:
- B5H0V36*K*AAA outdoor unit, AHRI 218172392, cooling 34,000 BTU/h, heating 35,600 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.5;
- B5H3V24*K*AAA outdoor unit, AHRI 218407179, cooling 23,000 BTU/h, heating 25,200 BTU/h at 47 °F, SEER2 19.5, HSPF2 9.5;
Notice the gap: the first combination delivers more capacity, the second shows better ratings. Neither is "the right one" in the absolute; it all depends on what your home requires. The ENERGY STAR matches published by Comfortmaker cover the SoftSound 20 / 23 (B5H0V, B5H3V) and Mainline 18 (C5H8T) heat pumps, all using R-454B, with ratings calculated with a furnace and a wall control ("+WALLCON").
Three questions to ask every contractor
- What is the AHRI number of the proposed system?
- Which outdoor unit goes with the coil?
- Is my furnace's blower sufficient, or does it need to be replaced?
If any of those answers stays vague, the quote lacks precision. With us, they are in writing.
Why 3.5 tons and not 3 or 4
In a large home, with several bedrooms upstairs and a finished basement, the cooling load often exceeds what a 3-ton can handle without straining, without justifying a 4-ton. This half step avoids paying for unused capacity while leaving a reasonable margin.
We always verify it by calculation. An oversized unit starts and stops constantly, dries the air poorly and wears out its components faster.
How it compares with the rest of the series
- ESH5X36M12A (3 tons): same B5H0V36*K*AAA outdoor unit, the route to explore if your load is a little lower;
- ESH5X42M12A (3.5 tons): the model described here;
- ESH5X48M12A (4 tons): moves to the B5H0V48*K*AAA unit, for distinctly larger homes;
- ESH5X24M12A and ESH5X30M12A (2 and 2.5 tons): reserved for small and medium homes;
- ESH5X60M12A (5 tons): the largest size in the series.
All share the same R-454B refrigerant, the TXV metering device, the cased design and the horizontal position.
What "horizontal" means
The manufacturer describes a horizontal coil with bidirectional airflow. It suits furnaces installed on their side: crawl space, attic, basement ceiling. The sloped, corrosion-resistant condensate pan sits under the exchanger and carries the water to the drain; its diameter is not published, which is why we check it on site. The refrigerant leak dissipation system is factory-mounted, according to the manufacturer's page.
The mistakes we see most often
The first is choosing the size based on the old unit. An air conditioner replaced twenty years ago was calculated for a different house, with different windows and different insulation. The second is forgetting the blower: a new coil behind a tired blower gives disappointing airflow. The third is comparing prices without comparing AHRI numbers.
Avoiding these three traps already prevents most unpleasant surprises. We take the time to go over them with you, with plans and measurements in hand.
About Comfortmaker
A brand of International Comfort Products (ICP), a subsidiary of Carrier, Comfortmaker designs central heat pumps and air conditioners whose R-454B coils install on a furnace or a blower cabinet. The two families of outdoor units mentioned above, SoftSound and Mainline, belong to that same brand.
Installation day
We start by protecting the floor and taking one last measurement. The coil goes into the plenum, with a custom-built insulated transition if the furnace width calls for it. Outside, the unit rests on a pad or bracket; the piping is brazed, tightness is checked with nitrogen, then the circuit is evacuated before the refrigerant is opened. The drain and the thermostat are connected, the airflow is adjusted, and we explain the whole system before we leave.
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
Warranty and registration
The manufacturer grants a 10-year limited parts warranty, provided the unit is registered within 90 days of installation; without registration, it is 5 years. We do this with you so that you do not lose the longest coverage.
What to check before choosing
- R-454B is matched with an outdoor unit using the same refrigerant, installed at the same time.
- The furnace must have the right width and blower.
- Grants depend on the complete system, not on the coil.
Heating, comfort and the bill
Paired with a heat pump, this coil lets you cool in summer and heat in winter through the same ducts. At mild temperatures, the heat pump delivers two to three times more heat than the electricity it uses, and the furnace takes over only when the cold intensifies. In a large home, the effect shows on the winter bill as well as on summer comfort.
LogisVert grant
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The ESH5X42M12A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H0V36*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H0V36*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.