COMFORTMAKER ESH5X60M12A Horizontal Evaporator Coil | 5 Tons
The Comfortmaker ESH5X60M12A 5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker B5H0V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberESH5X60M12A
514 316-2973 · sales@airgreen.ca
Quick facts
ESH5X60M12A: the large 5-ton Comfortmaker coil, reserved for truly large loads
The Comfortmaker ESH5X60M12A evaporator coil is the largest size in the ESH5X series: 5 tons, or 60,000 BTU/h nominal. Horizontal, cased and running on R-454B refrigerant, it is intended for large homes and furnace-heated buildings whose load clearly exceeds that of an ordinary residence. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Do you really need five tons?
That is the first question, and it deserves a real calculation. The reflex of "going big to be safe" often gives poor results: the unit cools in a short time, shuts off, restarts, and the humidity settles in. A five-ton size is justified when the house is vast, poorly shielded from the sun, or made up of several volumes that are hard to connect.
If the calculation points to the top of the range, it is the right choice. If it indicates a smaller size, we will tell you, even if it costs us the sale.
The two published certified systems
- B5H0V48*K*AAA outdoor unit, AHRI 218173679, cooling 45,500 BTU/h, heating 48,000 BTU/h at 47 °F, SEER2 16.5, HSPF2 8.5;
- B5H0V36*K*AAA outdoor unit, AHRI 218172437, cooling 34,600 BTU/h, heating 34,600 BTU/h at 47 °F, SEER2 16.5, HSPF2 8.5;
The first combination is the one that makes the most of the coil's size. The second, with a smaller outdoor unit, publishes a distinctly lower capacity: we mention it because it exists, but it only suits you if the actual load allows. Both have the same published efficiency ratings.
Remember that the ratings belong to the system and not to the coil alone. Comfortmaker publishes them with a furnace and a wall control ("+WALLCON"), for SoftSound 20 / 23 (B5H0V, B5H3V) and Mainline 18 (C5H8T) heat pumps, all using R-454B.
A job timeline
Before. Visit, furnace measurement, load calculation, checking the blower and the electrical panel. Written quote with the AHRI number.
First step. Coil installation in the plenum. If the width does not match, we build an insulated transition on site and seal the duct connections.
Second step. Outdoor unit installation on a pad or bracket, brazing of the piping, nitrogen leak test and evacuation.
Final step. Connection of the condensate drain and the thermostat, commissioning, airflow adjustment, explanation to the household.
AirGreen has been a family-owned heating and cooling company in Montreal for more than fifteen years, and this work is carried out under RBQ licence 5645-9605-01.
The blower, the sensitive point of large sizes
The larger the coil, the more air it needs. The furnace blower must deliver the system's airflow; otherwise, the coil gives less than it promises. We measure this at the visit and, if needed, we suggest adjustments before going further. It is often at this stage that the difference between a correct installation and a successful one is settled.
Finding your way in the ESH5X series
- ESH5X24M12A (2 tons) and ESH5X30M12A (2.5 tons): B5H3V24*K*AAA unit;
- ESH5X36M12A (3 tons) and ESH5X42M12A (3.5 tons): B5H0V36*K*AAA unit;
- ESH5X48M12A (4 tons): B5H0V48*K*AAA unit, with three published matches;
- ESH5X60M12A (5 tons): this one, with the same B5H0V48*K*AAA unit as the main match.
The 4-ton and the 5-ton therefore share their main outdoor unit. To decide, the calculated load settles it. All models in the series are horizontal and cased, with a TXV and R-454B.
What this coil does in practice
In summer, the refrigerant evaporates in the tubes and picks up heat from the air passing through; the condensation water falls into the sloped, corrosion-resistant pan, then reaches the drain. The drain diameter is not published, so we check it on site. The TXV metering device regulates the refrigerant flow. In winter, with a heat pump, the heat captured outside is delivered to the air of the house; the furnace remains as backup below the threshold programmed with you.
The manufacturer publishes a horizontal position with bidirectional airflow and a factory-installed refrigerant leak dissipation system.
Situations where five tons is justified
A large house with a flat roof and wide bay windows, a residence where several double-height rooms share the same air, a mixed-use building heated by a single furnace: these are cases where the top of the range makes sense. In such homes, a smaller size runs non-stop in hot weather and does not always manage to reach the requested temperature.
Conversely, an ordinary house, even a large one, does very well with a more modest size when the insulation is careful. We prefer an installation that is well proportioned to one that is impressive on paper.
Living with a large system
A large, well-tuned system fades into the background: it runs for long periods at a steady rate, distributes air smoothly and keeps humidity comfortable. For that, the airflow adjustment at commissioning matters as much as the choice of equipment. We take the time to do it room by room, check the thermostat and show you how the two seasons work.
After a few weeks, do not hesitate to tell us about any noise or any area that is less well served: a small adjustment is often enough.
One last tip before the visit
Gather a recent electricity bill, locate the panel and the furnace, and note the rooms that seem hardest to cool. This information saves us time and makes the quote more precise from the first visit.
Warranty
Limited 10-year parts warranty with registration within 90 days of installation, 5 years without registration. We register the unit with you at commissioning.
What to check before you buy
- R-454B is matched with an outdoor unit using the same refrigerant, installed at the same time.
- The furnace width and the blower capacity are confirmed during the visit.
- The electrical service must support the complete system.
Why choose Comfortmaker
Comfortmaker is part of International Comfort Products (ICP), a subsidiary of Carrier. Its R-454B evaporator coils go with central heat pumps and air conditioners designed for the same furnace or blower cabinet.
LogisVert grant
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The ESH5X60M12A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H0V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H0V48*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.