COMFORTMAKER ESH5X48M12A Horizontal Evaporator Coil | 4 Tons
The Comfortmaker ESH5X48M12A 4-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker B5H0V48*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberESH5X48M12A
514 316-2973 · sales@airgreen.ca
Quick facts
Three matches, one coil: the 4-ton Comfortmaker ESH5X48M12A
Most coils in the ESH5X series match one or two outdoor units. The ESH5X48M12A has three, which gives the owner of a large home real room to manoeuvre. It is a horizontal Comfortmaker evaporator coil, cased, rated at 4 tons (48,000 BTU/h nominal), that runs on R-454B refrigerant and installs on a furnace or a blower cabinet. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
The three certified systems, in detail
- B5H0V48*K*AAA outdoor unit, AHRI 218173643, cooling 44,500 BTU/h, heating 49,500 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.5;
- B5H3V36*K*AAA outdoor unit, AHRI 218410827, cooling 33,800 BTU/h, heating 34,600 BTU/h at 47 °F, SEER2 19.5, HSPF2 9.0;
- B5H0V36*K*AAA outdoor unit, AHRI 218172413, cooling 34,200 BTU/h, heating 35,400 BTU/h at 47 °F, SEER2 17.0, HSPF2 8.5;
The first match is the one closest to the nominal size: it offers the highest capacity of the three, in both cooling and heating. The second favours efficiency ratings, with a lower published capacity. The third sits between the two. Each has its own AHRI number; that number identifies the system you are buying.
How to choose among the three
Start with the question of load: how much heat does the house gain on a scorching day, and how much does it lose in winter? We calculate it at the visit. If the result approaches full capacity, the first match is the obvious choice. If the house is well insulated and the calculated load is more moderate, the second or the third may suit, with more favourable ratings.
We lay out these scenarios in the written quote. You see the capacities and ratings of each option before deciding.
What Comfortmaker states about its heat pumps
The ENERGY STAR matches cover the SoftSound 20 / 23 (B5H0V, B5H3V) and Mainline 18 (C5H8T) heat pumps, all using R-454B. The ratings are published with a furnace and a wall control ("+WALLCON"). The manufacturer's heating capacity at -8.3 °C ranges from 14,500 to 43,500 BTU/h depending on the match, a range that shows how much the choice of outdoor unit matters.
Where the 4-ton sits in the ESH5X series
- ESH5X24M12A (2 tons) and ESH5X30M12A (2.5 tons): B5H3V24*K*AAA unit, for the smallest floor areas;
- ESH5X36M12A (3 tons) and ESH5X42M12A (3.5 tons): B5H0V36*K*AAA unit, for medium and large homes;
- ESH5X48M12A (4 tons): this one, B5H0V48*K*AAA unit as the main match;
- ESH5X60M12A (5 tons): same B5H0V48*K*AAA unit, with an even larger load to serve.
If you are unsure between the 4-ton and the 3.5-ton, the difference comes down to the calculated load and the outdoor unit. If you are weighing it against the 5-ton, check whether the house really exceeds the 4-ton threshold before opting for more.
Homes that benefit from this size
Think of large two-storey homes, split-level houses, residences with a finished basement and large glazed areas. These are homes where the air has to travel long distances in the ducts and where a size that is too small never catches up with the afternoon heat.
Even in these homes, the load calculation remains the reference. A 4-ton in a house that does not need one costs more to buy and performs worse day to day.
The mechanics, demystified
In the furnace plenum, the coil acts as the exchanger. In summer, the refrigerant evaporates in its tubes and absorbs heat from the air passing through; the moisture condenses and slides into the sloped, corrosion-resistant pan, then to the drain, whose diameter is not published. The TXV metering device doses the refrigerant according to demand. In winter, with a heat pump, the heat captured outside is delivered to the air of the house, and the furnace keeps its role as backup for the deep cold.
The manufacturer indicates a horizontal position with bidirectional airflow, as well as a factory-mounted refrigerant leak dissipation system.
The comfort of a large home, room by room
In a large home, the temperature is never uniform. The main floor stays cool, the upper floor accumulates heat, and the finished basement leans toward the cold. A well-sized central system rebalances these differences by moving the air of the whole house through the same ducts. We take the visit as a chance to look at the air returns, the registers and the circulation between floors, because a good coil cannot make up for a poorly balanced duct network.
It is also the moment to talk about winter: the heat pump supplies most of the heating at mild temperatures, and the furnace, which you keep, is there for the rest of the cold season.
Why Comfortmaker
Comfortmaker belongs to International Comfort Products (ICP), a subsidiary of Carrier. Its SoftSound and Mainline outdoor units, paired with the ESH5X coils, form systems published with their AHRI numbers, which makes verification simple for the buyer.
What we do at your home
AirGreen has been a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. For a system of this size, we plan:
- a measuring visit, with an examination of the furnace, the blower and the electrical panel;
- mounting the coil in the plenum and an insulated transition on site if needed;
- installing the outdoor unit, brazed piping, the nitrogen test and evacuation;
- connecting the drain and the thermostat;
- commissioning, airflow adjustment and handing over the instructions.
Manufacturer warranty
The limited warranty covers parts for 10 years if the unit is registered within 90 days of installation, and for 5 years without registration. We take care of it for you.
What to check before choosing
- The coil has no efficiency rating of its own: the ratings belong to the matched system.
- R-454B requires a compatible outdoor unit, installed at the same time.
- The blower must deliver the system's airflow; a large size demands it especially.
- The furnace width is measured before the order is placed.
LogisVert grant
The matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we check it against the official list when we prepare your quote and we put the application together with you. Eligibility applies to the complete system.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The ESH5X48M12A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker B5H0V48*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker B5H0V48*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.