COMFORTMAKER EVM5X24M14A Evaporator V-Coil | 2 Tons

In stock

The Comfortmaker EVM5X24M14A 2-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVM5X24M14A

2 tons24,000 BTU/h nominal
14-3/16 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217953844
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVM5X24M14A
ManufacturerComfortmaker
Size2 tons
Width14-3/16 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V24*K*AAA

EVM5X24M14A: the 2-ton Comfortmaker evaporator coil for narrow furnaces

In many homes across the region, the furnace sits in a corner of the basement, squeezed between a concrete wall, the water heater and a row of shelves. When you talk about adding a central heat pump or replacing an old air conditioner, the first question isn’t "which brand?" but "will it fit?" The Comfortmaker EVM5X24M14A evaporator coil was designed for exactly that situation: it is the narrowest in its series, at 14-3/16 in wide.

It is a cased V-coil rated at 2 tons (24,000 BTU/h) and runs on R-454B refrigerant. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, on furnaces of all ages and sizes.

Why width matters so much

The coil sits on the furnace’s air outlet, inside the plenum. Its width has to follow the width of the furnace cabinet, otherwise air finds leaks and the casing doesn’t sit squarely.

At 14-3/16 in, the EVM5X24M14A suits small furnace cabinets, such as those found in plex units, townhouses and bungalows from a certain era. If your furnace is a little wider, we build an insulated transition on site. It isn’t a makeshift fix: it is a piece of insulated sheet metal, measured to your unit, that joins the two openings.

A 2-ton size for a smaller floor area

Two tons is the smallest size in the EVM5X series. It is meant for homes where the cooling load stays modest: a small apartment, a small bungalow, a well-insulated ground floor. A unit that is too big helps no one. It cools the air quickly, shuts off, restarts, and the moisture doesn’t condense enough on the tubes. You end up with a house that is cool but clammy.

Before confirming this size, we assess the real load of the house. If the calculation points to a larger coil, we tell you so frankly, and we explain why.

What comes in the box, and how it is installed

The EVM5X24M14A is delivered in an insulated casing: the coil, the condensate pan and the connecting piping form a single assembly. The PBT pan is sloped to drain water, with three sealed plugs that let you choose which side the drain exits.

The positioning is flexible. The manufacturer publishes a multipoise version, which can be installed in upflow, downflow or horizontal configurations. A furnace lying on its side in a crawl space or under a low ceiling is therefore not ruled out. The refrigerant connections are 3/8 in for the liquid line and 3/4 in for the suction line. The metering device is a TXV: it adjusts the refrigerant flow to the load.

On the safety side, this R-454B model includes an A2L leak sensor and a complete dissipation system, factory-installed or supplied, as described in data sheet EVM5X-51-01PD.

Summary data sheet

  • model: EVM5X24M14A, EVM5X series;
  • type: cased evaporator coil;
  • nominal size: 2 tons, or 24,000 BTU/h;
  • dimensions W × H × D: 14-3/16 × 14-11/16 in;
  • net weight: 26.5 lb, a unit that is easy to handle on a basement staircase;
  • refrigerant: R-454B; metering device: TXV;
  • manufacturer’s warranty: 10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.

What this coil does in an "add-on" heat pump

In an "add-on" setup, the furnace stays in place. It keeps its blower, its filters and its heating elements, and the coil is added in the plenum. In summer, cold refrigerant flows through its tubes and picks up heat and moisture from the air passing by. The water collected runs down into the pan and out to the drain.

In winter, if the outdoor unit is a heat pump, the cycle reverses: the coil becomes the surface that gives off heat to the air in the house. The furnace takes over as backup when the temperature drops below the threshold we set with you. If you have an electric furnace today, this is a major change in how you heat, while keeping the ductwork already in place.

The certified match and its ratings

A coil has no efficiency rating on its own. Ratings belong to the complete system, linked by an AHRI number. For the EVM5X24M14A, Comfortmaker publishes two matches:

  • with the Q5H9V24*K*AAA outdoor unit: AHRI 217953844, cooling 22,600 BTU/h, heating 23,800 BTU/h at 47 °F, SEER2 16.0 and HSPF2 8.1;
  • with the N5H9V24*K*AAA outdoor unit: AHRI 217953837, same capacities and same ratings.

When you compare quotes, ask for the AHRI number of each system. It is the only way to check that you are comparing equivalent systems.

The manufacturer also states that EVM5X matches with the Q5H9V and N5H9V units are ENERGY STAR certified for cold climates, and that heating capacity at -8.3 °C ranges from 19,600 to 45,500 BTU/h depending on the match. With a heat pump, the outdoor unit must have a piston metering device in heating mode.

EVM5X24M14A or another model in the series?

Here is how we help customers decide, relying only on the published data sheets.

  • EVM5X24M17A and EVM5X25M17A: the same 2-ton size, but 17-1/2 in wide. If your furnace is that width, they avoid the transition; if it is narrower, the EVM5X24M14A is the natural choice.
  • EVM5X30M17A, EVM5X31M17A, EVM5X32M17A: 2.5-ton size, also 17-1/2 in wide. You move up to these when the house needs a little more capacity.
  • EVM5X36M17A: 3 tons, for a larger house.
  • EVM5X42M21A: 3.5 tons at 21 in, matched with other outdoor units (B5H3V36*K*AAA).

All of these models share R-454B refrigerant, the TXV metering device and the casing. Width and capacity are therefore the two real selection criteria.

Questions we often hear

Can I keep my current air conditioner? Generally, no. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

My furnace isn’t 14-3/16 in wide. Is that a problem? No. We measure and, if needed, we build the insulated transition.

Will the furnace still be useful? Yes. It keeps its blower and serves as backup heating for the coldest days.

Our installation in Greater Montreal

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the visit and the work follow this order:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, building a transition if needed, sealing the joints;
  • installing the outdoor unit on a pad or bracket, brazed piping, nitrogen leak test and evacuation;
  • connecting the condensate drain and the thermostat;
  • commissioning, adjusting the airflow and explaining how the system works.

What to check before ordering

  • The coil uses R-454B: it is matched with an outdoor unit using the same refrigerant, installed at the same time.
  • The published ratings apply to the certified match, not to the coil alone.
  • The furnace blower must deliver the system’s airflow; we confirm this at your home.

LogisVert grant

The matched Comfortmaker system appears on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation: we confirm it on the official list when we prepare the quote, then put the application together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVM5X24M14A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Certified systemMatched with the Q5H9V24*K*AAA, the system carries AHRI 217953844.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVM5X24M14A
TypeCased evaporator coil
LineEVM5X
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D14-3/16 × 14-11/16 in
Net weight26.5 lb
Matched outdoor unitQ5H9V24*K*AAA, N5H9V24*K*AAA
System AHRI number217953844, 217953837
System SEER2 / HSPF216.0 / 8.1
Model numberEVM5X24M14A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-3/16 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.