COMFORTMAKER EVM5X36M17A Evaporator V-Coil | 3 Tons
The Comfortmaker EVM5X36M17A 3-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVM5X36M17A
514 316-2973 · sales@airgreen.ca
Quick facts
EVM5X36M17A: your questions about the 3-ton Comfortmaker coil
Homeowners looking at the Comfortmaker EVM5X36M17A evaporator coil almost always ask the same questions. We answer them here, one by one, using the data published by the manufacturer. It is a cased V-shaped coil rated at 3 tons (36,000 BTU/h), using R-454B refrigerant, that sits on a furnace or a blower cabinet. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Is it the right size for my home?
Three tons suits a large share of the bungalows and two-storey homes in the region: furnace in the basement, ducts to every room, and often an old central air conditioner or window units. But the size can’t be guessed from floor area alone. Insulation, orientation, windows and the number of occupants all count. We do a load calculation before recommending anything, and we tell you whether a smaller or larger size would serve you better.
Can my old central air conditioner stay?
Generally, no. This coil runs on R-454B, while the old equipment uses a different refrigerant. It has to be matched with the outdoor unit specified by the manufacturer, and the two components are installed together.
Does it heat too?
Yes, if the outdoor unit is a heat pump. In that case, the coil cools in summer and heats in winter, using the existing ducts. With a central air conditioner, it is used only for cooling. The furnace stays in place, with its blower and its filters, and serves as backup heating for the coldest nights.
What are the system ratings?
The coil has none on its own: they belong to the certified system. For the EVM5X36M17A, Comfortmaker publishes two matches:
- Q5H9V24*K*AAA: AHRI 217953940, cooling 23,400 BTU/h, heating 24,600 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.5;
- N5H9V24*K*AAA: AHRI 217953933, same capacities and same ratings.
These units are variable-speed heat pumps from the QuietComfort / Performance 19 SEER2 line, using R-454B. Comfortmaker lists EVM5X matches with Q5H9V or N5H9V that are ENERGY STAR certified for cold climates, and a heating capacity at -8.3 °C of 19,600 to 45,500 BTU/h depending on the match.
When you compare two quotes, ask for the AHRI number of each. It is the most reliable way to know whether they describe the same system.
Is it the same size as the others in the series?
No. The EVM5X36M17A measures 17-1/2 × 19-7/16 in and weighs 35.7 lb. Its 17-1/2 in width is shared by most models in the series; the difference between them comes down to nominal capacity and casing height.
What if my furnace isn’t that width?
We measure and, if needed, build an insulated transition on site. It is a common and clean solution: there is no risk of air escaping when the joints are properly sealed.
What exactly is in the casing?
- a multipoise V-coil: upflow, downflow or horizontal;
- a TXV metering device;
- 3/8 in (liquid) and 3/4 in (suction) connections;
- a sloped PBT pan with 3 sealed plugs;
- an A2L leak sensor and a complete dissipation system, factory-installed or supplied (data sheet EVM5X-51-01PD);
- a 10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.
Should I choose it over another model?
Let’s compare it with its neighbours in the series, using only the published data sheets.
- EVM5X30M17A, EVM5X31M17A, EVM5X32M17A: 2.5 tons, the same 17-1/2 in width. If the house needs less capacity, one of these models may be enough.
- EVM5X24M14A, EVM5X24M17A, EVM5X25M17A: 2 tons, for small homes and plex units. The EVM5X24M14A is the narrowest, at 14-3/16 in.
- EVM5X42M21A: 3.5 tons at 21 in, with a B5H3V36*K*AAA unit; it is meant for a larger house or a wider furnace.
The EVM5X36M17A therefore sits in the middle of the series by capacity, and it relies on the same outdoor unit as the smaller models.
How long does the work take?
We do it in a single installation visit planned in advance. We measure the furnace, install the coil, install the outdoor unit, braze the piping, run the nitrogen test and evacuation, then connect the drain and the thermostat. Commissioning and airflow adjustment finish the job. The exact timing depends on the layout of the house; we spell it out in the quote.
What about maintenance after installation?
Not much, but it counts. Change the furnace filter regularly: a clogged filter reduces the airflow through the coil, and the system works harder for a lesser result. Keep the return grilles clear, with no furniture or rugs blocking them. In spring, take a look at the condensate drain to make sure water flows freely.
Also remember to register the product: the 10-year limited parts warranty requires registration within 90 days of installation, otherwise it drops to 5 years. We remind you of this step at the end of the job and can help you do it.
Finally, plan to have a technician check the system from time to time. A clean coil, sealed piping and the correct refrigerant charge are the three conditions for stable operation, season after season.
Why does the blower matter?
The furnace blower has to deliver the system’s airflow. With a 3-ton size, the demand for air is greater than with a small model. We therefore check the motor, the speed setting, the filter and the condition of the return air paths. A well-chosen coil doesn’t make up for a choked duct system.
Our installation in Greater Montreal
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, custom transition if needed, sealed duct connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and explanations at your home.
What to check before choosing
- R-454B requires an outdoor unit with the same refrigerant, installed along with the coil.
- The ratings apply to the certified match.
- The furnace width and blower must be suitable; we confirm this at the visit.
LogisVert grant
The matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare the quote and put the application together with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The EVM5X36M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.