COMFORTMAKER EVM5X31M17A Evaporator V-Coil | 2.5 Tons

In stock

The Comfortmaker EVM5X31M17A 2.5-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberEVM5X31M17A

2.5 tons30,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 217953908
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberEVM5X31M17A
ManufacturerComfortmaker
Size2.5 tons
Width17-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitQ5H9V24*K*AAA

The EVM5X31M17A from the mechanical room: a tall 2.5-ton casing

On paper, the Comfortmaker EVM5X31M17A evaporator coil comes down to one line: cased V-coil, 2.5 tons (30,000 BTU/h), R-454B refrigerant, 17-1/2 in wide. In a mechanical room, it is something else. This model is 25-13/16 in tall and weighs 42.3 lb: it is a casing you see, lift and have to find room for. Here is what we look at in Montreal, Laval, Longueuil, on the North Shore and on the South Shore before proposing it.

First check: vertical clearance

At 25-13/16 in tall, the EVM5X31M17A needs room between the top of the furnace and the ceiling or the start of the ducts. We measure from the furnace’s air outlet, taking into account the existing sheet metal, the supports and whatever will need to be recut. In a basement with an unfinished ceiling, this is usually simple. Under a dropped ceiling or in a closed cabinet, we would rather know before delivery.

If space is too tight, another coil from the same series can solve the problem. We say so right away, rather than forcing an installation.

Second check: weight and access

At 42.3 lb, the casing is still manageable, but it has to be carried down a narrow staircase without bumping the walls. Two technicians take care of it, and the work is done with protection in place: we cover the floor and the steps. The 17-1/2 in width is no problem for getting through a standard basement door.

Third check: the furnace width

The 17-1/2 in wide casing has to connect to the furnace’s air outlet. When the furnace has a different size, we build an insulated transition. It is a routine job, which we do on site with sheet metal and insulation, rather than ordering a standard part that doesn’t fit.

What the certified ratings promise

A coil has no efficiency rating on its own. Here are the systems published by Comfortmaker with the EVM5X31M17A:

  • Q5H9V24*K*AAA: AHRI 217953908, cooling 23,800 BTU/h, heating 25,000 BTU/h at 47 °F, SEER2 16.5, HSPF2 8.5;
  • N5H9V24*K*AAA: AHRI 217953901, same capacities, SEER2 16.5 and HSPF2 8.5.

The SEER2 16.5 rating belongs to this specific system, not to a promise attached to the coil. If you replace the outdoor unit or the coil, the ratings change and you need to consult the sheet for the new match.

The Q5H9V and N5H9V units belong to Comfortmaker’s variable-speed QuietComfort / Performance 19 SEER2 line, using R-454B. The manufacturer describes them as ENERGY STAR certified for cold climates with the EVM5X, and publishes a heating capacity at -8.3 °C of 19,600 to 45,500 BTU/h depending on the match.

List of features

  • model EVM5X31M17A, cased coil, EVM5X series;
  • 2.5 tons, 30,000 BTU/h nominal;
  • dimensions W × H × D: 17-1/2 × 25-13/16 in; net weight: 42.3 lb;
  • 3/8 in liquid connection, 3/4 in suction;
  • sloped PBT pan with 3 sealed plugs;
  • TXV metering device; multipoise (upflow, downflow, horizontal);
  • A2L leak sensor and complete dissipation, factory-installed or supplied (data sheet EVM5X-51-01PD);
  • 10-year limited parts warranty with registration within 90 days of installation, 5 years without registration.

Planning installation day

A casing this size takes some preparation. Before the crew arrives, we clear access to the furnace with you: boxes, shelves and sometimes a dryer get moved. We also ask you to plan a spot for the condensate drain, either a floor drain nearby or a pump, which we assess during the visit.

In the morning, we install the casing and connect the refrigerant piping. By early afternoon, the outdoor unit is in place, and the pipes are brazed and pressurized with nitrogen to check for leaks. Evacuation comes next, then commissioning and airflow adjustment. Before leaving, we show you how the thermostat works and where each component is located.

If your furnace doesn’t have the right width, that day includes building the transition. We never leave a casing sitting on a poorly fitted opening: hot or cold air would escape through the joints and the system’s efficiency would suffer.

Finally, we clean up after ourselves. Sheet-metal offcuts, packaging and tools leave the house with us.

Heating: from electric to a heat pump

Many of our customers heat today with an electric furnace. Adding a heat pump changes the logic: instead of turning each kilowatt-hour into an equal amount of heat, the heat pump moves heat from outside to inside and delivers more than the electricity it consumes, especially in mild weather. The colder it gets, the less the unit delivers, which is why the furnace stays on as backup.

The coil is the surface through which heat enters the air in the house. In summer, it does the opposite job and removes heat and moisture.

How does it fit in the series?

  • EVM5X30M17A and EVM5X32M17A: the same 2.5-ton capacity and the same 17-1/2 in width. What changes: the casing and the AHRI sheet. The EVM5X32M17A adds a match with the B5H0V24*K*AAA unit.
  • EVM5X24M14A, EVM5X24M17A, EVM5X25M17A: 2 tons. The first is narrow, at 14-3/16 in.
  • EVM5X36M17A: 3 tons.
  • EVM5X42M21A: 3.5 tons, 21 in wide, with a B5H3V36*K*AAA unit.

TXV metering device and R-454B everywhere: neither helps you tell them apart. Count instead on the available space and on the ratings sheet.

What doesn’t change with a tall model

The furnace keeps its blower, its filters and its heating elements. The ducts stay the same. The thermostat controls the whole system. The only real difference is seen above the furnace, where a taller casing takes its place.

The AirGreen job, step by step

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil:

  • measuring the clearance and the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, custom transition if needed, sealed duct connections;
  • outdoor unit on a pad or bracket, brazed piping, nitrogen test and evacuation;
  • condensate drain and thermostat connected;
  • commissioning, airflow adjustment and explanation of how the system works.

What to check before choosing

  • The outdoor unit must use R-454B, like the coil, and be installed at the same time.
  • The published ratings apply to the certified match.
  • The furnace width, the clearance and the blower are confirmed during the visit.

LogisVert grant

The matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare the quote and put the application together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The EVM5X31M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Certified systemMatched with the Q5H9V24*K*AAA, the system carries AHRI 217953908.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerComfortmaker
ModelEVM5X31M17A
TypeCased evaporator coil
LineEVM5X
Nominal size2.5 tons (30,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 × 25-13/16 in
Net weight42.3 lb
Matched outdoor unitQ5H9V24*K*AAA, N5H9V24*K*AAA
System AHRI number217953908, 217953901
System SEER2 / HSPF216.5 / 8.5
Model numberEVM5X31M17A
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
COMFORTMAKER
See all
05 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5-ton Comfortmaker coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.