COMFORTMAKER EVM5X25M17A Evaporator V-Coil | 2 Tons
The Comfortmaker EVM5X25M17A 2-ton R-454B cased coil sits on your furnace and, matched with the Comfortmaker Q5H9V24*K*AAA outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberEVM5X25M17A
514 316-2973 · sales@airgreen.ca
Quick facts
EVM5X25M17A: reading the AHRI sheet for a 2-ton Comfortmaker coil
When a quote mentions an "EVM5X25M17A coil", it refers to a specific part: a cased V-shaped evaporator coil from the Comfortmaker EVM5X series, rated at 2 tons (24,000 BTU/h), using R-454B refrigerant. It measures 17-1/2 × 19-7/16 in. But the part on its own isn’t what matters for your comfort and your bill: it is the certified system it belongs to. This page explains how to read that system, using the real figures for the EVM5X25M17A.
We install this coil in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, on gas, oil or electric furnaces.
One number that ties three parts together
An AHRI number identifies a set: an outdoor unit, an indoor coil and, where needed, a blower. The published ratings (SEER2, HSPF2, capacities) apply only to that set. Change the coil and the figures change too.
For the EVM5X25M17A, Comfortmaker publishes two systems:
- with Q5H9V24*K*AAA: AHRI 217953876, cooling 23,400 BTU/h, heating 24,600 BTU/h at 47 °F, SEER2 16.0, HSPF2 8.5;
- with N5H9V24*K*AAA: AHRI 217953869, same capacities, SEER2 16.0 and HSPF2 8.5.
Keep in mind the three things these lines tell you: the cooling capacity, the heating capacity at 47 °F, and the seasonal rating for each mode.
SEER2 and HSPF2: what are they for?
SEER2 measures cooling efficiency over a season, and HSPF2 does the same for a heat pump’s heating. The higher the rating, the less electricity the system uses to deliver the same warmth or the same cooling. For this model, the system shows SEER2 16.0, HSPF2 8.5.
These values come from laboratories and standardized conditions. In your home, the result also depends on how well the ducts are sealed, on the insulation and on how the system is set up at commissioning. That is why we take the time to check the airflow, and not just plug the units in.
Heating in the cold: what the manufacturer says
A heat pump loses capacity when the outdoor temperature drops. Comfortmaker publishes a heating capacity at -8.3 °C that ranges from 19,600 to 45,500 BTU/h depending on the match. The EVM5X combinations with the Q5H9V and N5H9V units are ENERGY STAR certified for cold climates.
The furnace stays on as backup. It takes over below a temperature threshold that we set with you, based on the comfort you want and the energy rate you pay.
What is inside the casing
- V-coil, multipoise: upflow, downflow or horizontal;
- TXV metering device, which regulates the refrigerant flow;
- 3/8 in (liquid) and 3/4 in (suction) connections;
- sloped PBT pan, 3 sealed plugs to choose the drain outlet;
- net weight of 35.7 lb;
- A2L leak sensor and complete dissipation system, factory-installed or supplied, per data sheet EVM5X-51-01PD;
- 10-year limited parts warranty with registration within 90 days of installation, or 5 years without registration.
A height of 19-7/16 in: a good middle size
The EVM5X25M17A is taller than the lowest models in the series, without reaching the height of the largest. In practice, it needs a plenum with enough vertical clearance, and we measure for it during the visit. Many basement furnaces accommodate it without difficulty.
Its 17-1/2 in width is the same as that of several other models in the series. If the furnace is narrower or wider, we build a custom insulated transition.
Choosing between the EVM5X25M17A and its neighbours
- EVM5X24M14A: 2 tons, narrower at 14-3/16 in. It goes in small furnace cabinets.
- EVM5X24M17A: also 2 tons, 17-1/2 in wide, with its own AHRI sheet.
- EVM5X30M17A, EVM5X31M17A, EVM5X32M17A: 2.5 tons, the same 17-1/2 in width.
- EVM5X36M17A: 3 tons.
- EVM5X42M21A: 3.5 tons, 21 in, matched with B5H3V36*K*AAA.
The refrigerant, the metering device and the Q5H9V24*K*AAA outdoor unit are common to most of them. To tell apart two models of the same capacity, we place their AHRI sheets side by side and see which one matches the height, the width and the ratings you are looking for.
Asking your installer the right questions
Before you sign, ask: what is the AHRI number of the proposed system? Does the sheet really match this coil and this outdoor unit? Who checks the airflow at commissioning? A clear answer to these three questions says a lot about how seriously the work is done.
At AirGreen, we provide the quote in writing with the exact models, here the EVM5X25M17A and its outdoor unit. Nothing is left open to interpretation, and you can compare our offer with another one, line by line, using the AHRI number.
We also explain, in plain terms, what the system will do in your home: which rooms will be best served, where the air will come out, and what you will hear, or won’t hear, at start-up.
What this coil does not do
It produces neither cooling nor heat by itself: it exchanges heat with the air passing through it. It does not replace a blower, does not fix poorly sealed ducts and cannot be matched with an old outdoor unit. Because it runs on R-454B, the outdoor unit must use the same refrigerant and be installed at the same time.
The AirGreen installation, from measuring to start-up
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. Here is how it goes:
- measuring the furnace, checking the blower and the electrical panel;
- installing the coil in the plenum, building a transition if needed, sealed duct connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, evacuation;
- condensate drain and thermostat connected;
- commissioning, airflow adjustment and explanations on site.
What to check before choosing
- Same refrigerant (R-454B) for the coil and the outdoor unit.
- Ratings valid for the certified match only.
- Furnace width and blower capacity, confirmed during the visit.
LogisVert grant
The matched Comfortmaker system is on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation: we check it on the official list when we prepare the quote and help you put the application together.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Comfortmaker system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The EVM5X25M17A sits in the plenum of a furnace or air handler. Connected to the Comfortmaker Q5H9V24*K*AAA outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Comfortmaker Q5H9V24*K*AAA outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 17-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Explore the range
Evaporator coilsSee allSame brand
COMFORTMAKERSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2-ton Comfortmaker coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.