ELIOS GCHMA24RBAS1 Evaporator Coil | 2 Tons

In stock

The Élios GCHMA24RBAS1 2-ton R-454B cased coil sits on your furnace and, matched with the Élios ESHMA18R2AN1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberGCHMA24RBAS1

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216623472
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberGCHMA24RBAS1
ManufacturerÉlios
Size2 tons
Width17-1/2 in
RefrigerantR-454B
Outdoor unitESHMA18R2AN1

GCHMA24RBAS1: the small 2-ton Elios evaporator coil for plexes and bungalows

In many homes across Greater Montreal, the furnace is modest, the basement ceiling is low and the January electricity bill makes you wince. The Elios GCHMA24RBAS1 evaporator coil is meant for those homes. It is the smallest cased coil in the GCHMA line: 2 tons, or 24,000 BTU/h nominal size, 17-1/2 in wide and running on R-454B refrigerant.

We install it for customers in Montreal, Laval, Longueuil, the North Shore and the South Shore. Here is what you need to know to judge whether it suits your home.

What this coil does, in plain terms

Picture a car radiator, except that its job is to pull heat out of the air in your house. The coil sits above the furnace, in the path of the air. In summer, cold refrigerant flows through it and cools the air that the blower pushes toward the rooms. The water that condenses on the tubes drips into a pan and then runs to the drain.

With a heat pump, the cycle can reverse in winter. The air in the house then receives the heat captured outdoors. The same equipment serves both seasons, through the same vents.

Why a small size is an advantage

People often assume a bigger unit does more for you. In air conditioning, the opposite happens all too often. An oversized system reaches the requested temperature in a few minutes and then shuts off. The air has been cooled, but it has not had time to shed its moisture. The result is a house that is cool and clammy, and unpleasant to live in.

A 2-ton size suits townhouses, compact bungalows and plex units that have their own furnace. Before we propose it, we run a load calculation for the house. If the result calls for a larger size, we tell you frankly and point you to a neighbouring model in the series.

The two published pairings

A coil never works alone. For the GCHMA24RBAS1, Elios publishes two outdoor units:

  • ESHMA18R2AN1, AHRI number 216623472: 18,000 BTU/h cooling, 19,000 BTU/h heating at 47 °F, SEER2 16.1 and HSPF2 9.5;
  • ESHMA24R2AN1, AHRI number 216623473: 24,000 BTU/h cooling, 25,000 BTU/h heating at 47 °F, SEER2 16.0 and HSPF2 9.5.

The coil itself has no efficiency rating. The ratings belong to the complete system, and the AHRI number is what ties the two pieces together. When you compare two quotes, ask for this number: it tells you exactly what will be installed in your home.

An "add-on" heat pump: the furnace stays on the job

In an "add-on" installation, you do not throw out your furnace. It keeps its blower, its filters and its ductwork. When the outdoor temperature falls below a threshold that we set with you, it takes over as backup heat. This approach appeals to homeowners who want to reduce their consumption without giving up the security of a second system during the coldest weather.

It is also a practical way to turn an electric furnace into a central heat pump, or to replace an old central air conditioner with a new system.

How this model compares with its neighbours in the series

The choice comes down to size, width and whether there is a cabinet. Here is where the GCHMA24RBAS1 fits:

  • GUHMA24RBAS1, also 2 tons, but uncased and 16-1/8 in wide: it fits when the existing plenum is in good condition or space is tight;
  • GCHMA36RBAS1, a 3-ton model with the same 17-1/2 in width: it keeps the same footprint but gains height;
  • GCHMA36RCAS1, a 3-ton model 21 in wide, for a wider furnace;
  • GCHMA48RCAS1 (4 tons, 21-5/8 in) and GCHMA60RDAS1 (5 tons, 24-1/2 in), reserved for large homes.

If your home is small and your furnace is 17-1/2 in wide, this coil is the natural starting point. If the furnace is narrower or wider, the width of a neighbouring model will make more sense.

GCHMA24RBAS1 specifications

  • type: cased evaporator coil, GCHMA line;
  • nominal size: 2 tons (24,000 BTU/h);
  • refrigerant: R-454B;
  • dimensions (W × H × D): 17-1/2 × 18 × 21 in;
  • net weight: 41.89 lb;
  • connections: 3/8 in (9.52 mm) for the liquid line, 3/4 in (19 mm) for the suction line;
  • manufacturer's warranty: 1-year limited warranty on parts and 5-year limited warranty on the compressor; an optional 10-year warranty (parts and compressor) is available from a third party.

The cabinet is delivered insulated. It sits directly on the furnace, which speeds up the work and takes care of the seal at the spot where air leaks are costly.

What a heat pump changes day to day

An electric furnace converts each kilowatt-hour into an equal amount of heat, no more. A heat pump moves heat instead of making it: in mild weather, it delivers two to three times more heat than the energy it uses. As the cold sets in, that efficiency drops, which is why the backup heat stays useful.

In summer, you can say goodbye to window air conditioners. One outdoor unit, cool air in every room, and a single thermostat for both seasons.

What Elios publishes about its outdoor units

  • ESHMA and ESHMB lines (Central-Elios): cooling from -30 to 50 °C, heating from -30 to 24 °C;
  • ESHEA line (E-Match R): cooling from -25 to 50 °C, heating from -25 to 24 °C;
  • maximum line length of 30 m (98 ft) for 18,000 BTU/h, and 50 m (164 ft) for 24,000 BTU/h;
  • variable-speed (inverter) compressor;
  • outdoor units: 1-year limited warranty on parts and 5-year limited warranty on the compressor.

What to check before you buy

  • The coil runs on R-454B: it is paired with an outdoor unit that uses the same refrigerant, installed at the same time.
  • The published ratings apply to the certified pairing, not to the coil alone.
  • The 17-1/2 in width must match the width of the furnace. If it does not, we build an insulated transition on site.
  • The blower must deliver the system's airflow; we check this during our visit.

Frequently asked questions

Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.

Can this coil provide heat? Yes, with a heat pump. With a central air conditioner, it only provides cooling.

Our installation work in Greater Montreal

AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this coil and its outdoor unit, the job includes:

  • measuring the furnace and checking the blower and the electrical panel;
  • installing the coil in the plenum, with a transition built on site if needed;
  • installing the outdoor unit, brazed piping, a nitrogen leak test and evacuation;
  • connecting the condensate drain and the thermostat;
  • commissioning, setting the airflow and giving you a clear explanation of how the system works.

LogisVert subsidy

The paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and on your situation. We check it against the official list when we prepare your quote, and we put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The GCHMA24RBAS1 sits in the plenum of a furnace or air handler. Connected to the Élios ESHMA18R2AN1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Élios ESHMA18R2AN1 outdoor unit
Certified systemMatched with the ESHMA18R2AN1, the system carries AHRI 216623472.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerÉlios
ModelGCHMA24RBAS1
TypeCased evaporator coil
LineGCHMA
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Liquid connection3/8 in (9,52 mm)
Suction connection3/4 in (19 mm)
Dimensions W × H × D17-1/2 × 18 × 21 in
Net weight41.89 lb
Matched outdoor unitESHMA18R2AN1, ESHMA24R2AN1
System AHRI number216623472, 216623473
System SEER2 / HSPF216.1 / 9.5
Model numberGCHMA24RBAS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ÉLIOS
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Élios coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.