ELIOS GCHMA36RBAS1 Evaporator Coil | 3 Tons

In stock

The Élios GCHMA36RBAS1 3-ton R-454B cased coil sits on your furnace and, matched with the Élios ESHMA30R2AN1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberGCHMA36RBAS1

3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216623474
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberGCHMA36RBAS1
ManufacturerÉlios
Size3 tons
Width17-1/2 in
RefrigerantR-454B
Outdoor unitESHMA30R2AN1

Elios GCHMA36RBAS1: 3 tons in a narrow 17-1/2 in cabinet

Some furnaces are slim. You find them in two-storey homes, suburban cottages and basements where every inch counts. For those units, a coil that is too wide forces you to improvise a transition. The GCHMA36RBAS1 avoids that hassle: it delivers 3 tons (36,000 BTU/h) in a cabinet 17-1/2 in wide, and it runs on R-454B.

AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, above furnaces and blower cabinets of all makes.

One more step up in capacity, with the same footprint

Compare this model with its 2-ton neighbour, the GCHMA24RBAS1. The width is identical at 17-1/2 in, and so is the depth at 21 in. What changes is the height: 23-5/8 in instead of 18 in, and the net weight of 59.52 lb. The cabinet grows upward, not sideways.

This matters in practice. If your furnace is narrow but there is free space above it, you get 3-ton capacity without widening the plenum. Before ordering, we measure the available height, because the coil sits between the furnace and the start of the ductwork.

Dimensions and connections

  • model: GCHMA36RBAS1, cased evaporator coil, GCHMA line;
  • nominal size: 3 tons (36,000 BTU/h);
  • dimensions (W × H × D): 17-1/2 × 23-5/8 × 21 in;
  • net weight: 59.52 lb;
  • refrigerant: R-454B;
  • 3/8 in (9.52 mm) liquid connection and 3/4 in (19 mm) suction connection;
  • 1-year limited warranty on parts and 5-year limited warranty on the compressor; optional 10-year warranty (parts and compressor) available from a third party.

How to read a quote: the AHRI number

Two contractors can offer you "3 tons" and hand you different systems. The AHRI number settles the question, because it identifies one specific combination of coil and outdoor unit. For the GCHMA36RBAS1, Elios publishes two pairings:

  • ESHMA30R2AN1, AHRI 216623474: 29,000 BTU/h cooling, 30,000 BTU/h heating at 47 °F, SEER2 16.0 and HSPF2 9.6;
  • ESHMB36R2AN1, AHRI 216623811: 36,000 BTU/h cooling, 38,000 BTU/h heating at 47 °F, SEER2 15.8 and HSPF2 9.4.

Notice that the first pairing has the higher ratings of the two. A larger size therefore does not automatically mean better ratings. The choice depends on the load of the house, and that is what we calculate first.

The coil in the refrigeration loop

Liquid refrigerant arrives from the outdoor unit through the small line, expands in the coil and evaporates. As it evaporates, it absorbs heat from the air passing through the fins. The gas then returns to the compressor through the large line. Moisture in the air settles on the coil and runs off to the drain.

With a heat pump, this path reverses in the cold season. The furnace stays in place as backup heat: it starts when the outdoor temperature drops below the threshold programmed with you.

This model among the others in the series

  • GCHMA36RCAS1: same 3-ton capacity, but a cabinet 21 in wide and 24 in high. Choose it if the furnace is wider.
  • GUHMA36RBAS1: 3 tons uncased, 16-1/8 in wide, for fitting the coil into an existing plenum.
  • GUHMA36RCAS1: 3 tons uncased, 19-5/8 in wide.
  • GCHMA24RBAS1: 2 tons, same width, lower height.
  • GCHMA48RCAS1 and GCHMA60RDAS1: 4 and 5 tons for large homes.

The rule is simple: the cabinet width follows the furnace, and the capacity follows the house. The GCHMA36RBAS1 answers the combination of a narrow furnace and a mid-sized home.

What kind of home is it for?

Think of a two-storey cottage whose upper floor overheats in July, or an enlarged bungalow whose old air conditioner can no longer keep up. In those cases, 3 tons give the margin you need, without tipping into the excess that causes short cycling and sticky air.

This system also turns an electric furnace into a central heat pump, or replaces an ageing central air conditioner.

Frequently asked questions about this coil

My furnace has a different width. What can be done? We measure the furnace and, if needed, build an insulated transition on site. If the gap is large, a neighbouring model in the series may make more sense, and we will tell you so.

Can I keep my current air conditioner? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.

Can this coil heat the house? Yes, when it is paired with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it only provides cooling.

Is the furnace still useful? Yes. It keeps its blower and serves as backup heat when the outdoor temperature falls below the threshold we program with you.

What about subsidies? Eligibility depends on the paired system, not on the coil alone. We check Hydro-Québec's official list according to the installation date.

Why choose an insulated cabinet

A coil delivered in its cabinet arrives ready to install. The cabinet is insulated, it attaches directly to the furnace and it limits air leaks at the joint. For a unit that works in the plenum, this seal matters: the cooled or heated air must not escape before it reaches the rooms. If you would rather fit the coil into an existing plenum, the uncased version in the series, such as the GUHMA36RBAS1, meets that need.

Things to confirm before ordering

  • R-454B requires an outdoor unit with the same refrigerant, installed at the same time as the coil.
  • The coil has no efficiency rating of its own; only the ratings of the paired system count.
  • The 17-1/2 in width must match the furnace; we check it before ordering.
  • The blower must deliver the system's airflow.

What the manufacturer publishes for its outdoor units

The ESHMA and ESHMB lines operate in cooling from -30 to 50 °C and in heating from -30 to 24 °C. The maximum line length is 50 m (164 ft) for 24,000 and 30,000 BTU/h, and 75 m (246 ft) for 36,000, 48,000 and 60,000 BTU/h. The compressor is variable-speed. The outdoor units carry a 1-year limited warranty on parts and a 5-year limited warranty on the compressor.

Installation by AirGreen: what happens on the day

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. On installation day, our team:

  • measures the furnace and checks the blower and the electrical panel;
  • installs the cabinet on the furnace and seals the connections;
  • sets the outdoor unit, brazes the piping, runs the nitrogen test and pulls the vacuum;
  • connects the condensate drain and the thermostat;
  • sets the airflow and shows you how to use the system.

LogisVert subsidy

The paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation. We consult the official list when we prepare your quote, then put the file together with you.

Request your estimate

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. Financing is available to spread out the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The GCHMA36RBAS1 sits in the plenum of a furnace or air handler. Connected to the Élios ESHMA30R2AN1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Élios ESHMA30R2AN1 outdoor unit
Certified systemMatched with the ESHMA30R2AN1, the system carries AHRI 216623474.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerÉlios
ModelGCHMA36RBAS1
TypeCased evaporator coil
LineGCHMA
Nominal size3 tons (36,000 BTU/h)
RefrigerantR-454B
Liquid connection3/8 in (9,52 mm)
Suction connection3/4 in (19 mm)
Dimensions W × H × D17-1/2 × 23-5/8 × 21 in
Net weight59.52 lb
Matched outdoor unitESHMA30R2AN1, ESHMB36R2AN1
System AHRI number216623474, 216623811
System SEER2 / HSPF216.0 / 9.6
Model numberGCHMA36RBAS1
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ÉLIOS
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-ton Élios coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.