ELIOS GCHMA48RCAS1 Evaporator Coil | 4 Tons
The Élios GCHMA48RCAS1 4-ton R-454B cased coil sits on your furnace and, matched with the Élios ESHMA48R2AN1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberGCHMA48RCAS1
514 316-2973 · sales@airgreen.ca
Quick facts
Elios GCHMA48RCAS1: 4 tons for the big house on the South Shore or the North Shore
A large cottage, an expanded country house, a split-level with high ceilings: these buildings need more cooling than a standard-size coil can offer. The GCHMA48RCAS1 is the 4-ton cased coil in the Elios line. It delivers 48,000 BTU/h nominal size, measures 21-5/8 × 27-3/4 × 21-1/2 in, weighs 96.78 lb and runs on R-454B refrigerant.
A size reserved for large floor areas
In the series, there is only one 4-ton model and one 5-ton model. The others range from 2 to 3 tons. The GCHMA48RCAS1 therefore sits above most of its neighbours, and it is aimed at homes that need a larger heat output, such as those in Laval, on the North Shore, on the South Shore, in Longueuil or in large Montreal plexes.
Be careful, though, not to choose a large size "just in case". An oversized unit short-cycles, leaves moisture in the air and wears out its components faster. We always start with a load calculation, then propose the size that suits the house, not the one that happens to be in stock.
The cabinet: 27-3/4 in high, so plan for it
At a height of 27-3/4 in, this is a substantial cabinet. Before going any further, we measure the space between the top of the furnace and the ceiling or the start of the ductwork. In a low basement, this check can make the difference between a simple installation and an awkward fit.
The weight of 96.78 lb also deserves a mention. It takes two people to lift it and centre it on the furnace cabinet without damaging the insulation. Our crews are used to this work.
The certified pairing
For this model, Elios publishes a single system:
- outdoor unit ESHMA48R2AN1, AHRI number 216718862: 45,000 BTU/h cooling, 48,000 BTU/h heating at 47 °F, SEER2 15.2 and HSPF2 8.8.
Let's be transparent: the ratings of this system are a little lower than those of the smaller sizes in the series, which show higher SEER2 values. This is common with large capacities. If your home needs 4 tons, these ratings are those of the system you get, and the useful comparison is with another quote of the same capacity, AHRI number in hand.
What this coil does in an "add-on" heat pump
The coil sits in the furnace plenum. In summer, the refrigerant evaporates in it and absorbs heat from the air; the moisture condenses and runs off to the drain. In winter, with a heat pump, the cycle reverses and the heat captured outdoors passes into the air of the house. The furnace keeps its blower and its role as backup heat for the coldest weather.
It can be used to turn an electric furnace into a central heat pump or to replace an old central air conditioner.
Choosing between the GCHMA48RCAS1 and its neighbours
- GCHMA36RCAS1: 3 tons, 21 in wide. Almost the same width as the 4-ton, but for an average home.
- GCHMA60RDAS1: 5 tons, 24-1/2 in wide, for the highest demand in the series.
- GCHMA36RBAS1 and GCHMA24RBAS1: 3 and 2 tons, with a width of 17-1/2 in.
- GUHMA36RBAS1, GUHMA36RCAS1 and GUHMA24RBAS1: uncased models, narrower (16-1/8 in and 19-5/8 in).
The GCHMA48RCAS1 is therefore the coil to consider when the load calculation goes beyond 3 tons without reaching 5 tons.
Specifications
- type: cased evaporator coil, GCHMA line;
- nominal size: 4 tons (48,000 BTU/h);
- dimensions (W × H × D): 21-5/8 × 27-3/4 × 21-1/2 in;
- net weight: 96.78 lb;
- refrigerant: R-454B;
- connections: 3/8 in (9.52 mm) for the liquid line, 3/4 in (19 mm) for the suction line;
- 1-year limited warranty on parts and 5-year limited warranty on the compressor; optional 10-year warranty (parts and compressor) available from a third party.
Airflow: the key to large systems
The bigger a system is, the more air it needs. If the furnace blower is too weak or the ducts are narrow, the coil does not give its full performance: the air circulates poorly, the coil frosts up or the house stays uneven. That is why, before any commitment, we measure the blower and the condition of the existing ductwork. In any case where we have a doubt, we say so clearly before quoting.
What the manufacturer publishes for the outdoor unit
The ESHMA line operates in cooling from -30 to 50 °C and in heating from -30 to 24 °C. The maximum line length is 75 m (246 ft) for the 36,000, 48,000 and 60,000 BTU/h units. The compressor is variable-speed, and the warranty on the outdoor units is limited to 1 year on parts and 5 years on the compressor.
Questions we are often asked
Can my old air conditioner stay? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.
My furnace is a different width than 21-5/8 in. We measure it and, if needed, build an insulated transition on site, so that all of the air passes through the coil.
Is the furnace still useful with a heat pump? Yes. It keeps its blower and acts as backup heat below the threshold we program with you.
Does the coil alone qualify for a subsidy? No, it is the paired system that is assessed. We check Hydro-Québec's official list according to the installation date.
Checks before purchase
- The coil is paired with an R-454B outdoor unit, installed at the same time.
- The published ratings are those of the certified system, not of the coil alone.
- The 21-5/8 in width must match the furnace; we check it before ordering.
- The blower must deliver the system's airflow.
The AirGreen installation in Greater Montreal
AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our job includes:
- measuring the furnace and checking the blower and the electrical panel;
- setting the cabinet with two people and sealing the duct connections;
- the outdoor unit on a base or bracket, brazed piping, nitrogen test and evacuation;
- the condensate drain and the thermostat;
- commissioning, airflow adjustment and an explanation of how the system works.
LogisVert subsidy
The paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the quote stage and prepare the file with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The GCHMA48RCAS1 sits in the plenum of a furnace or air handler. Connected to the Élios ESHMA48R2AN1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Élios ESHMA48R2AN1 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21-5/8 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ÉLIOSSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Élios coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.