ELIOS GCHMA60RDAS1 Evaporator Coil | 5 Tons
The Élios GCHMA60RDAS1 5-ton R-454B cased coil sits on your furnace and, matched with the Élios ESHMA60R2AN1 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberGCHMA60RDAS1
514 316-2973 · sales@airgreen.ca
Quick facts
GCHMA60RDAS1: the 5-ton coil, top of the GCHMA line
At the top of the Elios cased-coil range sits the GCHMA60RDAS1. Its numbers speak for themselves: 5 tons, or 60,000 BTU/h nominal size; a 24-1/2 × 28 × 21 in cabinet; 81.13 lb; operation on R-454B refrigerant. It is the largest model in the series described here.
It is aimed at large homes in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, as well as buildings with a large furnace.
A curious fact: bigger, but lighter than the 4-ton
This coil weighs 81.13 lb, while the narrower 4-ton GCHMA48RCAS1 is heavier according to its data sheet. Why? Because weight depends on the internal construction of the coil and its cabinet, not only on nominal capacity. Simply remember that capacity cannot be guessed from the load you lift, and that the data sheet takes precedence over intuition.
What changes clearly is the width: 24-1/2 in. Few residential furnaces reach this width, which points this model toward large cabinets.
Five tons: when is it justified?
Few homes truly need a size like this. The candidates are large multi-storey residences, homes with a big open area, or buildings whose envelope lets a lot of heat through. In many cases, a serious load calculation brings the recommendation back to 4 tons, or even 3.
Our role is to check before installing. If the calculation shows that your home does not need 5 tons, we tell you and steer you toward a smaller model. A system that is too big runs in short cycles and leaves the air humid.
Certified system and published ratings
For the GCHMA60RDAS1, Elios publishes a single pairing:
- outdoor unit ESHMA60R2AN1, AHRI number 216623476: 47,000 BTU/h cooling, 58,000 BTU/h heating at 47 °F, SEER2 15.2 and HSPF2 8.1.
An honest note: the published cooling capacity (47,000 BTU/h) is lower than the nominal size of the coil, while the heating capacity (58,000 BTU/h at 47 °F) comes close to it. These figures describe the paired system, and we present them as they are on the quote so that you can compare them.
Anatomy of an installation on a large furnace
The cabinet sits on top of the furnace and receives all the air leaving the blower. Every inch of clearance counts: with a height of 28 in, we need to check the space before the supply plenum. We also measure the available airflow, because a large coil depends on a blower able to push the right volume through it.
The furnace keeps its heating elements and its backup role for the coldest days. It starts only below the threshold we program with you.
This model next to its neighbours
- GCHMA48RCAS1: 4 tons, 21-5/8 in wide, one step down in capacity.
- GCHMA36RCAS1 and GCHMA36RBAS1: 3 tons, 21 in and 17-1/2 in wide.
- GCHMA24RBAS1: 2 tons, 17-1/2 in wide, for small homes.
- GUHMA24RBAS1, GUHMA36RBAS1, GUHMA36RCAS1: uncased models, 2 and 3 tons only.
The GCHMA60RDAS1 is the only one in the series to go beyond 4 tons. If your need is lower, a smaller neighbour will be a better fit.
Specifications
- type: cased evaporator coil, GCHMA line;
- nominal size: 5 tons (60,000 BTU/h);
- dimensions (W × H × D): 24-1/2 × 28 × 21 in;
- net weight: 81.13 lb;
- refrigerant: R-454B;
- connections: 3/8 in (9.52 mm) for the liquid line, 3/4 in (19 mm) for the suction line;
- 1-year limited warranty on parts and 5-year limited warranty on the compressor; optional 10-year warranty (parts and compressor) available from a third party.
What this means for comfort
A heat pump moves heat instead of making it. In mild weather, it delivers two to three times more heat than the electricity it uses, and that efficiency falls as the cold deepens. This is why the furnace keeps a backup role. In summer, the same coil cools and dries the air in every room, through the same ducts, with no window units.
This system makes it possible to turn an electric furnace into a central heat pump, or to replace an old, large central air conditioner.
What Elios publishes about the outdoor units
- ESHMA line (Central-Elios): cooling from -30 to 50 °C, heating from -30 to 24 °C;
- maximum line length of 75 m (246 ft) for 36,000, 48,000 and 60,000 BTU/h;
- variable-speed (inverter) compressor;
- 1-year limited warranty on parts and 5-year limited warranty on the compressor.
Frequently asked questions
Can my current air conditioner be used with this coil? Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer. We install the complete system.
Can this coil provide heat? Yes, with a heat pump: it cools in summer and heats in winter. With a central air conditioner, it provides cooling only.
My furnace is not the same width. What can be done? We measure the furnace and, if needed, build an insulated transition on site.
Is the furnace still useful? Yes. It keeps its blower and serves as backup heat when the outdoor temperature falls below the threshold we program with you.
And the subsidy? Eligibility depends on the paired system, not on the coil alone. We check Hydro-Québec's official list according to the installation date.
How to read the quote
On a written AirGreen quote, you will find the coil model, the outdoor unit model, the AHRI number that links them and the published ratings for the system. When you compare with another offer, check that these four items are present. Without them, there is no way to know whether you are comparing two systems of the same kind.
Before ordering
- R-454B requires an outdoor unit with the same refrigerant, installed at the same time as the coil.
- The coil has no rating of its own; the ratings belong to the paired system.
- The 24-1/2 in width must match the furnace; we check this before ordering.
- The blower must deliver the system's airflow.
Installation by AirGreen
AirGreen is a family-owned heating and cooling company, based in Montreal for more than fifteen years, with RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work. Here is how it unfolds:
- measuring the furnace, checking the blower and the electrical panel;
- setting the cabinet, sealing the duct connections, building a transition if needed;
- outdoor unit, brazed piping, nitrogen test, evacuation;
- condensate drain and thermostat;
- commissioning, airflow adjustment and demonstration.
LogisVert subsidy
The paired Elios system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check it against the official list at the quote stage and prepare the file with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Elios system. Financing is available to spread out the cost of the project.
The heat pump coil for your furnace
The GCHMA60RDAS1 sits in the plenum of a furnace or air handler. Connected to the Élios ESHMA60R2AN1 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Élios ESHMA60R2AN1 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
ÉLIOSSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Élios coil, installed by AirGreen