GOODMAN CAPTA3626B3 Evaporator A-Coil | 2 to 3 Tons

In stock

The Goodman CAPTA3626B3 2 to 3-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPTA3626B3

2 to 3 tons36,000 BTU/h nominal
17-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPTA3626B3
ManufacturerGoodman
Size2 to 3 tons
Width17-1/2 in
RefrigerantR-32
MeteringTXV

CAPTA3626B3: 2 to 3 ton capacity in a 17-1/2 in Goodman cabinet

Open the basement door of a typical bungalow in Montreal or Longueuil: a furnace, ducts running off in every direction and, often, an old central air conditioner outside. This is the situation the Goodman CAPTA3626B3 evaporator coil is aimed at. It is a cased A-coil rated 2 to 3 tons (36,000 BTU/h), using R-32 refrigerant, in a narrow 17-1/2 in cabinet.

We follow it through the year, from summer to winter, to show what it changes in the home. Our crews install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Summer: cool air in every room

As soon as the outdoor unit starts, the refrigerant reaches the coil and evaporates in its tubes. The air in the house, moved by the blower, passes through the two sloped faces of the A and comes out cooled. It also loses some of its moisture, which drains to the pan and then to the drain.

The result is most noticeable in rooms far from the furnace, which window air conditioners reached poorly. One thermostat setting, one unit to maintain, and the ducts already in place serve as the distribution network.

Fall and spring: the season where the heat pump shines

When the temperature stays mild, a heat pump matched with this coil moves heat from outside to inside. It delivers two to three times more than the electricity it uses, which an electric furnace cannot do, since it turns every kilowatt-hour into an equal amount of heat.

At these temperatures, the investment starts to show on your Hydro-Québec bill, without the furnace having to run.

Winter: the furnace keeps its post

When it is very cold, a heat pump's efficiency drops. The furnace, which keeps its blower, its filters and its heating elements, then takes over below a temperature threshold that we set with you. You therefore lose no security: the add-on system adds options rather than removing any.

The 2 to 3 ton size, a good balance point

This range fits a large share of the bungalows and cottages in the region. It still calls for a check: we run a load calculation before recommending anything, because an oversized system starts and stops constantly, and an undersized one chases the temperature.

The 2 to 3 ton range is the coil's nominal size. The final capacity depends on the outdoor unit chosen.

How it fits among the CAPTA models

  • Same capacity, different width: the CAPTA3626C3 is 21 in wide for a larger furnace.
  • Same width, less capacity: the CAPTA3026B3 is also 17-1/2 in, in a 1.5 to 2.5 ton size.
  • More capacity: the CAPTA4230C3 (21 in) and CAPTA4230D3 (24-1/2 in) go up to 2.5 to 3.5 tons, and the CAPTA6030C3 and CAPTA6030D3 to 3.5 to 5 tons.

All have the same R-32 refrigerant and the same TXV. To decide, ask two questions: how wide is my furnace, and what load does my house require?

What the spec sheet says

  • model: Goodman CAPTA3626B3, CAPTA series;
  • cased evaporator coil;
  • nominal size: 2 to 3 tons (36,000 BTU/h);
  • refrigerant R-32; TXV metering device;
  • dimensions (W × H × D): 17-1/2 × 26 × 21 in;
  • connections: 3/8 in for the liquid, 7/8 in for the suction;
  • positions: upflow or downflow;
  • R-32 refrigerant sensor designed for the life of the coil.

The cabinet and the TXV, two details that matter

The insulated cabinet arrives with the coil. Installation is faster and sealing is better than when a coil is inserted into an improvised plenum. The TXV, for its part, adjusts the refrigerant flow to the load of the moment; the coil thus keeps stable operation when the outdoor temperature varies.

Efficiency ratings and matching

The SEER2, EER2 and HSPF2 ratings attach to a complete system, identified by an AHRI number. We confirm it before the order. At our last check, no R-32 match of this coil was listed in ENERGY STAR; the outdoor unit is therefore evaluated in the AHRI directory.

An installation built to last

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Our work includes:

  • measuring the furnace and checking the blower and the electrical panel;
  • mounting the coil in the plenum, with a transition built if needed, and sealing the connections;
  • the outdoor unit on a pad or bracket, brazed piping, the nitrogen test and the vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and explanations given at your home.

How an installation day unfolds

In the morning, the crew protects the floor, cuts power to the furnace and opens the plenum. The coil and its cabinet are put in place, plumb and level, so that the condensate drains properly to the drain. The duct connections are sealed, then insulated.

In the middle of the day, the outdoor unit takes its place on its pad, the copper lines are run and brazed, then pressure-tested with nitrogen. Next comes the vacuum, which removes air and moisture from the circuit before refrigerant flows through it.

At the end of the day, we connect the thermostat, measure the airflow and go over the settings with you. You leave with the steps to follow for the filters and the shoulder season.

Maintenance: what extends the life of the coil

A clean filter protects the coil's fins from dust, which interferes with heat exchange. Check it regularly, especially in the heating season when the furnace runs a lot. The condensate drain also deserves a look at the start of summer: if it clogs, the water looks for another way out.

The built-in R-32 refrigerant sensor is designed to last as long as the coil. It does not replace a maintenance visit, but it adds monitoring to the system.

Checks before buying

  • An R-32 outdoor unit is required, installed at the same time as the coil.
  • The advertised ratings apply to the certified match.
  • The furnace must be the right size and have a blower that delivers the required airflow.

Goodman, warranty and incentives

Goodman is part of Daikin Comfort Technologies. Its limited warranty covers parts for 10 years; online registration within 60 days is not required in Quebec.

For Hydro-Québec programs, what counts is the matched system and the installation date, not the coil alone. We check the official list when we prepare the quote.

Take the next step

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPTA3626B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPTA3626B3
TypeCased evaporator coil
LineCAPTA
Nominal size2 to 3 tons (36,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D17-1/2 × 26 × 21 in
Model numberCAPTA3626B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2 to 3-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom