GOODMAN CAPTA4230D3 Evaporator A-Coil | 2.5 to 3.5 Tons

In stock

The Goodman CAPTA4230D3 2.5 to 3.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPTA4230D3

2.5 to 3.5 tons42,000 BTU/h nominal
24-1/2 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPTA4230D3
ManufacturerGoodman
Size2.5 to 3.5 tons
Width24-1/2 in
RefrigerantR-32
MeteringTXV

CAPTA4230D3: a 24-1/2 in cabinet for the 2.5 to 3.5 ton size

Large furnaces have wide cabinets. When you fit a coil narrower than the plenum, you end up improvising sheet metal and joints, and the air finds the leaks. The Goodman CAPTA4230D3 solves this situation: it is a cased A-shaped evaporator coil, rated 2.5 to 3.5 tons (42,000 BTU/h), using R-32 refrigerant, with a width of 24-1/2 in.

The page that follows describes its role, its installation and how it differs from the other CAPTA models. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

The D3 compared with the C3: width only

The CAPTA4230C3 and the CAPTA4230D3 offer the same nominal capacity, the same TXV, the same refrigerant and the same connections. They differ in width: 21 in for the first, 24-1/2 in for the second. The rest of the decision comes down to your furnace's cabinet.

That is why we start with the tape measure. A cabinet of the right size means air that passes well through the coil and does not escape at the sides.

A wide furnace, a generous plenum

This size is meant for cottages and large single-storey homes whose ducts serve many rooms. The coil has more exchange surface than the smaller sizes, and the system requires more airflow, which the blower must provide.

During the assessment, we check the blower's capacity, the size of the plenum and the condition of the return ducts before confirming the size. If something is off, we propose a fix and put it in the quote.

CAPTA4230D3 model sheet

  • manufacturer: Goodman, CAPTA series;
  • type: cased evaporator coil;
  • nominal size: 2.5 to 3.5 tons (42,000 BTU/h);
  • refrigerant: R-32 with TXV metering device;
  • dimensions (W × H × D): 24-1/2 × 30 × 21 in;
  • connections: 3/8 in for the liquid, 7/8 in for the suction;
  • possible positions: upflow or downflow;
  • R-32 refrigerant sensor designed for the life of the coil.

Where it sits in the series

In the CAPTA series, 24-1/2 in cabinets exist only in the two largest sizes. In plain terms:

  • for a 24-1/2 in furnace with a load of 2.5 to 3.5 tons, this is the CAPTA4230D3;
  • for a 24-1/2 in furnace with a load of 3.5 to 5 tons, it is the CAPTA6030D3;
  • for a narrower 21 in furnace, the CAPTA4230C3 and CAPTA6030C3 take over;
  • for smaller loads, the CAPTA3026B3, CAPTA3026C3, CAPTA3626B3 and CAPTA3626C3.

The path of the air and the heat

The blower sends the house air upward, to the centre of the A, which spreads it across its two sloped faces. The refrigerant, on the other side of the tubes, changes state and absorbs heat in summer. The condensation falls into the pan and goes to the drain. In heating mode with a heat pump, the refrigerant instead delivers the heat picked up outside by the outdoor unit.

Why the furnace stays useful

An electric furnace creates an amount of heat equal to the electricity it consumes. A heat pump moves heat, and supplies two to three times more thermal energy than the electricity consumed in mild weather. When it is really cold, this ratio drops: the furnace then takes over, according to a threshold that we set together. You therefore keep a backup system without paying for a second heating appliance.

SEER2, EER2, HSPF2: what to rely on

Efficiency ratings are not read off the coil, but off the certified system, linked by an AHRI number. This number lets you compare two quotes on an equal footing and is used by incentive programs.

The CAPTA4230D3 is paired with a Goodman outdoor unit of the same capacity and the same refrigerant. At our last check, no R-32 match with this coil was listed in ENERGY STAR; we therefore go through the AHRI directory for the unit selected.

Our installation method

A family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. Every job includes:

  • measuring the furnace, checking the blower and the electrical panel;
  • installing the coil in the plenum, with a transition built if needed, and sealing the ducts;
  • the outdoor unit on a pad or bracket, brazed piping, the nitrogen test and the vacuum;
  • connecting the condensate drain and the thermostat;
  • commissioning, airflow adjustment and handing over the usage instructions.

When a transition beats changing the model

Sometimes a furnace is barely narrower or wider than the chosen cabinet. Rather than multiply part numbers, we build an insulated sheet-metal transition, carefully sealed, that connects the plenum to the cabinet. This is common practice on the job, and it keeps the benefit of the cabinet supplied with the coil.

The transition should remain an exception, though. If the gap is large, it is better to choose the model whose width is closest: less sheet metal, fewer joints, less risk of air leakage.

Think about the shoulder seasons

In fall and spring, when temperatures stay mild, the heat pump does most of the work in a home of this size. These are the times when the furnace runs the least and the difference shows on the electricity bill. In summer, the same coil cools the whole house through the existing ducts, without window units.

Frequently asked questions, short answers

Can my old air conditioner stay? Generally not: the coil runs on R-32, and the outdoor unit must be the one specified by the manufacturer.

My cabinet is narrower than 24-1/2 in. Move to the CAPTA4230C3 or let us build an insulated transition.

Can it only cool? Yes, with a central air conditioner. It also heats when paired with a heat pump.

To confirm before ordering

  • The outdoor unit must be R-32 and installed at the same time as the coil.
  • The published ratings belong to the certified match.
  • The furnace must have the width and a blower with the required airflow; we confirm this at your home.

Goodman, the brand and the warranty

Goodman is one of the brands of Daikin Comfort Technologies, along with Daikin and Amana. Its 10-year limited warranty covers parts; online registration within 60 days after installation is not required in Quebec.

Hydro-Québec programs

Eligibility is judged on the matched system and the installation date, not on the coil alone. We consult the official list when we prepare the quote.

Plan the visit

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPTA4230D3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPTA4230D3
TypeCased evaporator coil
LineCAPTA
Nominal size2.5 to 3.5 tons (42,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 × 30 × 21 in
Model numberCAPTA4230D3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5 to 3.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom