GOODMAN CAPTA6030C3 Evaporator A-Coil | 3.5 to 5 Tons
The Goodman CAPTA6030C3 3.5 to 5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCAPTA6030C3
514 316-2973 · sales@airgreen.ca
Quick facts
CAPTA6030C3: a 3.5 to 5 ton Goodman coil for the large home, above all a matter of electrical circuit and ducts
In a large home, the coil is never the only topic of discussion. Goodman's CAPTA6030C3 is an A-shaped evaporator coil, with a 21 × 30 × 21 in cabinet, rated 3.5 to 5 tons (60,000 BTU/h), using R-32 refrigerant. It is aimed at large properties in Montreal, Laval, Longueuil, the North Shore and the South Shore. At this scale, it is the electrical service and the air distribution that make a project succeed.
Who needs 3.5 to 5 tons?
This size is meant for large homes, properties with a finished basement and homes enlarged over the years. An added kitchen, an extra floor, an enclosed sunroom: each addition brings needs that the original furnace did not anticipate.
We tell you frankly when two smaller systems would serve the home better. In a house with several wings, two furnaces and two coils can spread comfort better than a single big unit that struggles to reach the far rooms.
First point to check: the electrical service
The outdoor unit that goes with this coil requires a dedicated circuit. In an older home whose panel has few free breakers, the panel sometimes has to be reviewed before talking about a heat pump. Our electrical work is done under our own RBQ licence 5645-9605-01: we assess the panel during the visit and include it in the quote, with no subcontractor to coordinate.
Second point: air distribution
The system reaches its full performance only if the airflow of the duct network is sufficient. We examine the blower, the size of the plenum and the diameter of the return ducts. An undersized network, inherited from a time when the house was smaller, will not let through the air that a coil of this capacity demands.
This is a subject to raise at the very first visit, because correcting the ducts costs less before installation than after.
21 in or 24-1/2 in?
The CAPTA6030C3 is installed on furnaces 21 in wide. For a 24-1/2 in cabinet, the same capacity exists in the CAPTA6030D3. Between them, there is no difference in capacity or refrigerant: only the width changes. If you hesitate between these two models, measuring the cabinet, rather than the catalogue, will make the difference.
If the load calculation reveals a more modest need, the CAPTA4230C3, at 2.5 to 3.5 tons, shares the 21 in width.
One big system or two smaller ones?
A single system is simpler to maintain: one outdoor unit, one thermostat, one coil to watch. In return, everything depends on a duct network able to distribute air everywhere. Two systems cost more in equipment but offer two independent zones, which helps when the upper floor and the basement do not have the same needs.
We present both options on paper, with the advantages of each, before you decide. No pressure: the right choice is the one that suits your home and the way you live in it.
The finished basement, a special case
A finished basement adds rooms to cool, but it stays naturally cooler than the upper floors. In that case, a good part of the cooling load is concentrated upstairs. We take this into account in the calculation, because it would be a shame to pay for capacity that is lost in rooms that are already cool.
CAPTA6030C3 dimensions and connections
- brand and series: Goodman CAPTA;
- nominal size: 3.5 to 5 tons (60,000 BTU/h);
- refrigerant: R-32; metering device: TXV;
- dimensions (W × H × D): 21 × 30 × 21 in;
- liquid connection: 3/8 in; suction connection: 7/8 in;
- positions: upflow or downflow;
- insulated cabinet supplied; R-32 refrigerant sensor designed for the life of the coil.
What the coil accomplishes
In the path of the air, in the plenum, the coil receives liquid refrigerant, which evaporates in its tubes in summer and cools the air. The condensed moisture is collected in the pan and removed through the drain. With a heat pump, the cycle reverses in winter and the coil becomes the exchanger that heats the air in the ducts.
The furnace keeps its blower, its filters and its heating elements. In a large home where winter nights can be harsh, this backup is valuable: it steps in below the temperature threshold that we set with you.
How efficient? Ask for the AHRI number
The coil carries no efficiency rating: SEER2, EER2 and HSPF2 relate to the matched system, identified by an AHRI number. For a large home, the difference between two systems adds up in kilowatt-hours over the whole season, and the number lets you compare.
The CAPTA6030C3 is matched with a Goodman outdoor unit of the same capacity and the same refrigerant. At our last check, no R-32 match of this coil was listed in ENERGY STAR; we rely on AHRI.
How a job of this size unfolds
AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, plans this kind of project in stages:
- measuring the furnace, checking the blower, the electrical panel and the ducts;
- installing the coil in the plenum, a transition built if needed, sealing the connections;
- outdoor unit on a pad or bracket, brazed piping, nitrogen leak test, vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment, explanations to the homeowner.
To confirm before ordering
- The outdoor unit must use R-32 and be installed at the same time as the coil.
- The advertised ratings apply to the certified match, not to the coil alone.
- The furnace must be the right size and have a blower that delivers the required airflow.
The brand and its warranty
Goodman is part of Daikin Comfort Technologies, like Daikin and Amana. The 10-year limited warranty covers parts; online registration within 60 days after installation is not required in Quebec.
Incentives
Hydro-Québec programs assess the complete system according to the installation date, not the coil taken alone. We check the official list when we prepare the quote and tell you what applies.
Get your quote
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CAPTA6030C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5 to 5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.