GOODMAN CAPTA4230C3 Evaporator A-Coil | 2.5 to 3.5 Tons

In stock

The Goodman CAPTA4230C3 2.5 to 3.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCAPTA4230C3

2.5 to 3.5 tons42,000 BTU/h nominal
21 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCAPTA4230C3
ManufacturerGoodman
Size2.5 to 3.5 tons
Width21 in
RefrigerantR-32
MeteringTXV

CAPTA4230C3: a 30 in tall Goodman cabinet for homes needing 2.5 to 3.5 tons

A cabinet 30 in tall means more exchange surface for larger homes, but also a question to settle before installation: is there enough clearance above the furnace? The Goodman CAPTA4230C3 evaporator coil measures 21 × 30 × 21 in (width, height, depth) and is aimed at the 2.5 to 3.5 ton size.

This R-32 A-coil, rated 42,000 BTU/h, is installed for our customers in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Here is what you need to know.

Clearance above the furnace

In a basement, the plenum is often squeezed between the furnace and beams, ducts or a finished ceiling. With a cabinet 30 in tall, we measure the available space before going any further. When the margin is thin, we look for a solution: moving a duct, adjusting the plenum or, if that is not enough, reconsidering the choice of model.

This work is done before the order, during the visit, not on installation day.

More surface, more airflow

The 2.5 to 3.5 ton size is meant for cottages and large single-storey homes whose ducts serve many rooms. The coil offers more exchange surface, and the system needs more airflow than the smaller sizes.

That airflow comes from the furnace blower. We look at its capacity, the size of the plenum and the condition of the return ducts before confirming the size. A well-sized coil paired with a limited blower does not deliver what it promises.

21 in or 24-1/2 in: choosing the width

The CAPTA4230C3 is the 21 in version. Its twin, the CAPTA4230D3, offers the same nominal capacity in a 24-1/2 in cabinet. There is no winner: the right model is the one that extends your furnace's cabinet. An insulated transition, built on site, can bridge a small gap.

If the load calculation says otherwise

  • Less capacity: the CAPTA3626C3 (2 to 3 tons, 21 in) or, for a 17-1/2 in cabinet, the CAPTA3626B3.
  • More capacity: the CAPTA6030C3 (3.5 to 5 tons) in the same 21 in wide cabinet.
  • Different width: the CAPTA4230D3, at 24-1/2 in.

All these models use R-32 and a TXV.

What is published for the CAPTA4230C3

  • brand and series: Goodman CAPTA;
  • cased evaporator coil;
  • nominal size: 2.5 to 3.5 tons (42,000 BTU/h);
  • refrigerant: R-32, TXV metering device;
  • dimensions (W × H × D): 21 × 30 × 21 in;
  • connections: 3/8 in (liquid) and 7/8 in (suction);
  • installation positions: upflow or downflow;
  • R-32 refrigerant sensor designed for the life of the coil.

For which homes?

Think of the large single-storey home on the North Shore whose living room, kitchen and three bedrooms are fed by the same duct network, or the Laval cottage with one more floor than the original furnace was meant for. These homes need more cooling in summer, and the coil has to keep up without the blower running out of breath.

We do not recommend this size by reflex. If the load calculation shows that the 2 to 3 ton range is enough, we tell you: why pay for capacity the house will never use?

The behind-the-scenes of summer comfort

Besides lowering the temperature, the coil removes moisture from the air. This water condenses on the fins and runs to the drain, which makes the house drier, and therefore more comfortable at the same temperature. For this role to be filled well, the airflow must be set carefully at commissioning, and this is a point we measure before leaving.

How the coil works with the heat pump

Installed in the plenum, the coil receives refrigerant from the outdoor unit. In summer, the liquid evaporates in its tubes and removes heat from the air passing through; the condensation water goes to the pan and then to the drain. In winter, if the outdoor unit is a heat pump, the direction of the cycle is reversed and it is the coil that delivers the heat.

The furnace keeps its heating elements and its blower. It serves as backup when the outdoor temperature falls below the threshold that we set with you.

Efficiency rating: read the AHRI number

A coil has no SEER2, EER2 or HSPF2 on its own. These ratings attach to the certified system, that is, to the combination of a coil, an outdoor unit and an AHRI number. We confirm this number before ordering.

The CAPTA4230C3 is matched with a Goodman outdoor unit of the same capacity and the same refrigerant. At our last check, no R-32 match with this coil appeared in ENERGY STAR; we refer to AHRI.

Installation day

A family-owned heating and cooling company in Montreal for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01. Our crew:

  • measures the furnace and the clearance, checks the blower and the electrical panel;
  • installs the coil in the plenum, builds a transition if needed and seals the duct connections;
  • places the outdoor unit on a pad or bracket, brazes the piping, runs the nitrogen test and the vacuum;
  • connects the condensate drain and the thermostat;
  • commissions the system, adjusts the airflow and gives you the usage instructions.

An installation without bad surprises

Before ordering, we photograph the plenum, note the furnace orientation (upflow or downflow) and check where the condensate drain will run. These details seem trivial, but they avoid return trips to the store and jobs that drag on. You then receive a written quote that lists every element of the system.

Homeowner checklist

  • The outdoor unit must run on R-32 and be installed at the same time as the coil.
  • The published ratings apply only to the certified match.
  • The furnace must have the necessary width, clearance height and blower.

Goodman and its warranty

Goodman belongs to Daikin Comfort Technologies, which also makes Daikin and Amana. The 10-year limited warranty covers parts; online registration within 60 days after installation is not required in Quebec.

Hydro-Québec incentives

Assistance depends on the complete system and the installation date, not on the coil alone. We check the official list at the quote stage.

Book your visit

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CAPTA4230C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCAPTA4230C3
TypeCased evaporator coil
LineCAPTA
Nominal size2.5 to 3.5 tons (42,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D21 × 30 × 21 in
Model numberCAPTA4230C3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 21 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5 to 3.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.