The Trane 4TXCA002RS3 1.5 to 2-ton R-410A cased coil sits on your furnace and, matched with a matching Trane outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number4TXCA002RS3
514 316-2973 · sales@airgreen.ca
Quick facts
4TXCA002RS3: the smallest Trane coil in the series, for a 14-1/2 in furnace
In a Longueuil townhouse, a compact Laval bungalow or a Montreal plex, the furnace often sits in a closet or a corner of the basement, and every inch counts. The Trane 4TXCA002RS3 evaporator coil is built for exactly that situation: a cased A-coil rated 1.5 to 2 tons (24,000 BTU/h), 14-1/2 in wide and 17-1/2 in tall. It runs on R-410A refrigerant and belongs to the Trane 4TXC line.
We install it across the whole region: Montreal, Laval, Longueuil, the North Shore and the South Shore.
What this coil actually does
The coil is the part that exchanges heat with the air in your home. Refrigerant arrives from the outdoor unit, evaporates inside the tubes and cools the air that the furnace blower pushes through the assembly. Without it, the outdoor unit has nothing to feed indoors.
If the outdoor unit is a heat pump, the same coil works in the other direction in winter. It becomes the point where the heat captured outside is released into the air in your ducts. One piece of indoor equipment, then, for two seasons.
A compact home, a compact size
The 1.5 to 2 ton size is meant for smaller living spaces: row houses, older bungalows, duplex or triplex floors that each have their own furnace. An oversized unit shuts off before it has dried the air enough. The result is a correct temperature but a damp, muggy feel. In a small volume, that flaw shows up quickly.
That is why we always start from a load calculation rather than a habit. If the calculation points to a larger size, we tell you frankly and steer you toward a neighbouring model in the series.
The dimensions that matter on the installation plan
Here is what Trane publishes for this model, presented the way we read it on the job site:
- 14-1/2 in wide, to compare with the width of the furnace plenum;
- 17-1/2 in tall and 21-1/2 in deep, which settles whether the space above the furnace is enough;
- net weight of 34 lb, easy to handle on a narrow staircase;
- 3/8 in liquid line connection and 3/4 in suction line connection;
- 3/4 in NPT condensate drain;
- possible positions: upflow, downflow or horizontal.
The coil comes in an insulated cabinet. It therefore goes onto the furnace in one piece, with no need to build a box around it.
Choosing between the 4TXCA002RS3 and its neighbours in the series
The series has ten models, grouped into four widths: 14-1/2 in, 17-1/2 in, 21 in and 24-1/2 in. The model shown here is one of the two narrowest and covers the smallest capacity range, 1.5 to 2 tons. Here is how to place it.
- 4TXCA032RS3: the same 14-1/2 in width, but a range of 1.5 to 3 tons. If the home is small today but an addition is possible, this neighbour leaves more room.
- 4TXCB003RS3: a range of 1.5 to 3 tons on a 17-1/2 in width. It suits a wider furnace.
- 4TXCB004RS3: 2 to 3.5 tons, also in 17-1/2 in.
- 4TXCC005RS3: 2 to 4 tons, in 21 in.
All of them share R-410A refrigerant and the TXV expansion valve. The real question is therefore the width of your furnace, then the load of the home. The rest follows.
The A shape and the TXV expansion valve
The two sloped faces of the coil meet at the top. Air rises through the centre and passes through both surfaces. This layout suits upflow furnaces well, which are very common in Quebec housing.
The TXV adjusts the flow of refrigerant entering the coil according to the load at that moment. It avoids flooding the tubes when demand is low and starving the end of the coil when demand is high.
Electric furnace, add-on heat pump: the typical scenario
Many of our customers in small homes heat with electric baseboards or an electric furnace. Adding a heat pump to the existing furnace changes the picture without redoing the duct network: the blower, the filters and the vents stay in place. The furnace keeps a backup role when the outdoor temperature drops below the threshold we set with you.
Another common scenario is replacing an old central air conditioner whose coil is worn out. In that case, the new assembly goes in as a single piece, with the matching outdoor unit.
Matching with the outdoor unit and the AHRI number
A coil on its own has no efficiency rating. The ratings you see on a quote describe a matched system: this coil, that outdoor unit, linked by an AHRI number. We verify that number before ordering, so that the figures promised are the ones you will get.
Trane also states that its R-410A coils in this family are intended for replacement, not for a new installation (reference COR-PSD012A-EN). In other words, they suit mostly the case where a system using the same refrigerant is already in place. We confirm this during the visit.
Our installation method, from the plenum to the thermostat
- We measure the furnace and check the blower and the electrical panel.
- We set the coil in the plenum, with an insulated transition built on site if the width does not match, then we seal the joints.
- We install the outdoor unit on a stand, braze the piping, run the nitrogen pressure test and pull a vacuum.
- We connect the condensate drain and the thermostat.
- We set the airflow and explain how everything works in your home.
Frequently asked questions about this model
Can it heat? Yes, with a heat pump. With a central air conditioner, it only cools.
Can I keep my current outdoor unit? Generally not: the coil and the outdoor unit are chosen together, with the same refrigerant.
My furnace is not exactly 14-1/2 in. What can I do? We take measurements and, if needed, build an insulated transition.
Is the furnace still useful? Yes, it keeps its blower and takes over in extreme cold.
Incentives and eligibility
Hydro-Québec programs apply to the complete system, not to the coil alone. When we prepare the quote, we check the match on the official list according to the installation date, then tell you what applies to your project.
Trane and AirGreen
Trane, a Trane Technologies brand, makes residential and commercial heating and cooling equipment. AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years; our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
What to check before placing the order
- The refrigerant of the existing system must be R-410A.
- The width of the furnace, the clearance above it and the capacity of the blower.
- The certified match with the outdoor unit, confirmed by its AHRI number.
Get your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The 4TXCA002RS3 sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Trane outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 14-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5 to 2-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.