TRANE 4TXCD008RS3 Evaporator A-Coil | 3.5 to 5 Tons
The Trane 4TXCD008RS3 3.5 to 5-ton R-410A cased coil sits on your furnace and, matched with a matching Trane outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model number4TXCD008RS3
514 316-2973 · sales@airgreen.ca
Quick facts
Trane 4TXCD008RS3: the 24-1/2 in width for large furnaces
At the top of the Trane 4TXC series, the width goes up to 24-1/2 in. The 4TXCD008RS3 is the shorter of the two models of this width: a cased A-coil of 3.5 to 5 tons (60,000 BTU/h) on R-410A refrigerant, with a TXV expansion valve, 24-1/2 in wide, 26-3/4 in tall and 21-1/2 in deep. It weighs 64 lb net.
Why width matters so much
A coil that matches the width of the furnace lets air through without choking it. At 24-1/2 in, this model is meant for large furnaces, often installed in the more spacious homes of Laval, the North Shore or the South Shore, as well as in some blower cabinets in Montreal or Longueuil.
Head to head with the 4TXCD010RS3
The two 24-1/2 in models cover the same range, 3.5 to 5 tons. What separates them is height and weight: the 4TXCD008RS3 is 26-3/4 in tall and weighs 64 lb; the 4TXCD010RS3 is taller and heavier. If the clearance above the furnace is limited, the first is easier to fit. If space is plentiful, the second is also possible.
Our role is to measure first, then decide. A cabinet that is too tall is caught before the order, not on the day of the work.
And compared with the 21 in models?
The 4TXCC009RS3 also offers 3.5 to 5 tons, but at 21 in wide. So it is not capacity that guides you here: it is the furnace. If it measures 21 in, the 4TXCC009RS3 is the one. If it measures 24-1/2 in, the 4TXCD008RS3 avoids a transition. A 17-1/2 in furnace, finally, points to the 4TXCB006RS3, at 2 to 5 tons.
The technical data in brief
- Nominal capacity: 3.5 to 5 tons, or 60,000 BTU/h.
- Liquid line connection: 3/8 in. Suction line connection: 7/8 in.
- Condensate drain: 3/4 in NPT.
- Positions: upflow, downflow, horizontal.
- Expansion device: TXV.
A less humid summer
What strikes our customers most, after the first heat wave, is not the temperature but the humidity. A well-matched system removes water from the air before sending it back, and the clammy feeling disappears. The water collected in the pan flows out through the 3/4 in NPT drain.
This assumes a system that is not oversized. That is why a load calculation comes before every proposal, including those that lead to a large coil like this one.
Three typical jobs for this model
The large North Shore cottage. The owners want to replace an ageing central air conditioner and add a heat pump. The wide furnace takes the cabinet without a transition. The job is simple, quick, clean.
The Laval home with an addition. A room was added a few years ago and the system in place struggles to keep up. The load calculation confirms the need for high capacity. The plenum has enough height: the 4TXCD008RS3 goes in without modification.
The Montreal plex. An owner-occupant wants to cool their unit and the one above with a single system. The shared furnace is large, the height is limited: the shortest model in the 24-1/2 in width is the right choice.
What your blower must be able to do
A coil with a large surface works well only if the blower can move the matching volume of air through it. A fixed-speed blower that is too weak causes the coil to frost up; a properly adjusted blower provides a steady exchange. We check the motor, the capacitor and the selected speed before installing anything.
In some cases, a variable-speed motor is a good idea. We discuss it during the visit, case by case, without imposing anything.
Heat pump, cooling only and backup
Paired with a heat pump, this coil serves for heating and cooling with the existing ducts. The furnace keeps its blower and its filters, and takes over below the threshold we program with you. Paired with a central air conditioner, it provides cooling only.
The AHRI number rather than a rating
Efficiency ratings belong to the matched system, not to the coil. An AHRI number links them. We confirm it before the order. Trane adds that its R-410A coils in this family are for replacement only (COR-PSD012A-EN): we therefore check your current system.
How the work unfolds
- Measuring the furnace, the blower and the electrical panel.
- Setting the cabinet, joints sealed, transition if needed.
- Outdoor unit on a stand, piping brazed, nitrogen test, vacuum.
- Drain and thermostat connected.
- Airflow adjustment, demonstration at your home.
A word on noise
A large coil in a large furnace does not necessarily make more noise: it all depends on the airflow and the condition of the ducts. A well-balanced system produces a steady, almost imperceptible flow of air. If you hear a whistle at the vents, it is usually a sign of a duct that is too narrow or a closed register. We measure the pressure before concluding and correct as needed.
The outdoor unit is placed away from bedroom windows and on a stable base. A vibrating support transmits noise to the structure; we avoid it by choosing the location well.
A quote you can read, line by line
Each quote we provide states the model number of the coil, that of the matched outdoor unit, the AHRI number of the system and the list of the work included. You can compare it, line by line, with another contractor's. If a piece of information is missing elsewhere, it is a good chance to ask the question.
Questions our customers ask at the end of the visit
Do I need to be away on the day of the work? No, but we cut power to the furnace for part of the day.
Do we need to clear the space around the furnace? Yes, a clear path speeds up the job and protects your belongings.
What happens if a surprise turns up? We show it to you, explain the options and wait for your agreement before changing the quote.
Incentives
Hydro-Québec programs apply to the complete system. We confirm the match on the official list according to the installation date and tell you what applies.
To check before deciding
- Refrigerant of the system in place: R-410A.
- Furnace width: 24-1/2 in.
- Clear height for a 26-3/4 in cabinet.
- Capacity of the blower and the electrical panel.
A local company
AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. Trane is a Trane Technologies brand.
Estimate and financing
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The 4TXCD008RS3 sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Trane outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5 to 5-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.