4TXCC005RS3: the 2 to 4 ton Trane coil for 21 in furnaces
When the furnace is 21 in wide, you enter the "wide" half of the Trane 4TXC series. The 4TXCC005RS3 is its entry point: a cased A-coil rated 2 to 4 tons (48,000 BTU/h) on R-410A refrigerant, with a TXV expansion valve. Its published dimensions are 21 × 22-1/2 × 21-1/2 in (W × H × D), for a net weight of 52 lb.
Here is what we see most often when we propose it in Montreal, Laval, Longueuil, on the North Shore or on the South Shore.
The classic scenario: the two-storey home
The owner has a good-sized gas or electric furnace, a central air conditioner at the end of its life, and a multi-storey home whose cooling is uneven. They want a new, discreet system that cools in summer and, if possible, cuts winter heating. The 21 in width matches many furnaces of this kind.
The 2 to 4 ton range covers most homes of this profile, from the small two-storey house to the large cottage. The load calculation determines the outdoor unit; the coil, for its part, adapts within this range.
Three questions to ask before ordering
- Is the furnace really 21 in wide? If not, an insulated transition is possible, but it adds work.
- How much height is there above the plenum? The cabinet is 22-1/2 in tall.
- What is the refrigerant of the current system? This coil is an R-410A model.
None of these answers can be guessed over the phone. A measuring visit settles all three in a few minutes.
Connections and drain
The liquid line connection is 3/8 in, the suction line connection is 7/8 in, and the condensate drain is 3/4 in NPT. Trane allows upflow, downflow and horizontal positions. The cabinet is insulated: it limits condensation on its outer surface, which protects the plenum and the neighbouring joists.
4TXCC005RS3 or 4TXCC007RS3?
These two models have the same 21 in width. The first covers 2 to 4 tons; the 4TXCC007RS3 covers 3 to 4 tons, with a taller cabinet. If the load calculation falls in the lower part of the range, two to three tons, only the 4TXCC005RS3 fits. In the upper part, the two are equal on paper, and the choice then comes down to the space available above the furnace.
For homes that need much more, the 4TXCC009RS3 goes up to 5 tons in the same width.
And if my furnace is narrower?
You have narrower models available: the 4TXCB004RS3 covers 2 to 3.5 tons on 17-1/2 in, and the 4TXCB006RS3 goes from 2 to 5 tons on the same width. Putting a wide cabinet on a narrow furnace forces you to build one more fitting; you might as well choose the right model from the start.
The add-on heat pump, without changing the ducts
The coil sits in the plenum and receives refrigerant from the outdoor unit. With a heat pump, it also serves for heating: the heat captured outside is given up to the air that passes through the coil, then distributed by the existing ducts. The furnace keeps its filters and its blower, and takes over below the temperature threshold we set with you.
It is a pragmatic approach: you keep what works and add what is missing.
Where to find the efficiency?
On the system and not on the coil. The published ratings belong to a certified assembly, identified by an AHRI number. We confirm that number before the order. Trane also indicates that this family of R-410A coils is intended for replacement only, and not for a new installation (COR-PSD012A-EN). If your existing system uses R-410A, you are in the right situation.
The steps we take on site
We start by measuring and checking the furnace, the blower and the electrical panel. Next, we install the coil in the plenum and seal the duct connections. The outdoor unit is set on its stand, the piping is brazed, the nitrogen test is done and the vacuum is pulled. The drain and the thermostat are connected. To finish, we adjust the airflow and explain everything.
A concrete example: a Brossard cottage
A couple owns a two-storey cottage on the South Shore. The gas furnace is about ten years old and works well, but the original central air conditioner is worn out. Every summer, the upper floor reaches temperatures that are hard to bear while the living room stays cool. They hesitate between replacing only the air conditioner and moving to a heat pump.
At the visit, we measure the furnace: 21 in wide, a plenum in good condition, an electrical panel that is sufficient. We explain that the chosen coil is the same in both cases; what changes is the outdoor unit. With a heat pump, the gas furnace becomes a backup and heats only when the heat pump is no longer enough. With an air conditioner alone, summer is solved, but winter does not change.
The couple chooses the heat pump. We order the matched coil and outdoor unit, and we confirm their AHRI number in the directory before the order. On the day of the work, everything goes without surprises because the measurements were taken in advance.
Humidity, the real judge of size
Many people judge their system on temperature alone. The right measure is also relative humidity. A system that is too big cools the air so fast that it shuts off before removing the water from the air; the home is cool, but sticky. A properly sized system runs longer per cycle and dries better.
That is why the 2 to 4 ton range of this coil is an asset: it lets you fit the outdoor unit as closely as possible to the calculated load, without changing the cabinet.
What you can expect for incentives
Hydro-Québec incentives depend on the complete system and not on the coil alone. We check the match on the official list when we prepare the quote, according to the installation date, and tell you what applies, without promising anything in advance.
One last job-site tip
Photograph the nameplate of your furnace before our visit, and note whether the air comes out at the top or the bottom. These two pieces of information let us prepare the visit and arrive with the right questions. They do not replace the measurement, but they make it faster.
Common questions
Can this coil heat? Yes, with a heat pump. With an air conditioner, it only cools.
Can I keep my outdoor unit? Generally not, because it must be matched to the coil.
Is the furnace still useful? Yes, as backup heating for extreme cold.
About Trane and AirGreen
Trane is a Trane Technologies brand. AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01.
Have your furnace measured
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The 4TXCC005RS3 sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Trane outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
TRANESee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 4-ton Trane coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.