TRANE 4TXCA032RS3 Evaporator A-Coil | 1.5 to 3 Tons

In stock

The Trane 4TXCA032RS3 1.5 to 3-ton R-410A cased coil sits on your furnace and, matched with a matching Trane outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model number4TXCA032RS3

1.5 to 3 tons36,000 BTU/h nominal
14-1/2 inwidth
R-410Arefrigerant
R-410AAdd-on heat pumpCasedR-410A
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model number4TXCA032RS3
ManufacturerTrane
Size1.5 to 3 tons
Width14-1/2 in
RefrigerantR-410A
MeteringTXV

Trane 4TXCA032RS3: up to 3 tons in a cabinet only 14-1/2 in wide

Some furnaces are narrow, but the home they heat is not. A South Shore cottage with a compact furnace, or a large Laval bungalow fitted with a small blower cabinet: the Trane 4TXCA032RS3 coil answers that combination. It is a cased A-coil rated 1.5 to 3 tons (36,000 BTU/h) on R-410A refrigerant, and its width stays at 14-1/2 in. To gain capacity, it is the height that changes: 22-1/2 in.

Where this model fits

Picture an upflow furnace whose plenum is 14-1/2 in wide. A wider coil would require a major transition, sometimes impossible to fit. The 4TXCA032RS3 avoids that constraint. It sits in the natural extension of the plenum and accepts a Trane outdoor unit of the same capacity.

We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, on an electric furnace as well as on a unit the customer wants to keep as backup.

What you need to know about its size

The published dimensions are 14-1/2 in wide, 22-1/2 in tall and 21-1/2 in deep, with a net weight of 41 lb. The liquid line connection is 3/8 in, the suction line connection is 3/4 in, and the condensate drain is 3/4 in NPT. The manufacturer provides three positions: upflow, downflow and horizontal.

The height is the figure that decides everything. Before ordering the model, we check the clear space above the furnace, which takes a few minutes with a tape measure but which nobody does over the phone.

The case of the 4TXCA002RS3, its direct neighbour

The 4TXCA002RS3 shares the same width and the same insulated cabinet, but it stops at 2 tons. The choice comes down to one sentence: if the home's load stays modest and the ceiling of the utility room is low, the smaller one is enough; if the home needs more, or if you plan to expand, the 4TXCA032RS3 gives you room to manoeuvre.

There is also the 4TXCB003RS3, which offers the same range of 1.5 to 3 tons, but for a 17-1/2 in furnace, so the range does not settle it; the width does.

How does it compare with the other widths in the series?

  • Width of 14-1/2 in: this model and the 4TXCA002RS3
  • Width of 17-1/2 in: 4TXCB003RS3, 4TXCB004RS3 (2 to 3.5 tons) and 4TXCB006RS3 (2 to 5 tons)
  • Width of 21 in: 4TXCC005RS3, 4TXCC007RS3 and 4TXCC009RS3
  • Width of 24-1/2 in: 4TXCD008RS3 and 4TXCD010RS3, both 3.5 to 5 tons.

All the models use R-410A refrigerant and the TXV expansion device. This uniformity simplifies the comparison: only the width, the tonnage range and the height really vary.

An installation day seen from the inside

The technician starts by cutting power to the furnace and removing the old coil, if there is one. He then cleans the plenum, positions the insulated cabinet and checks that it sits level: a coil tilted the wrong way makes the condensate pan overflow.

The copper piping is brazed, then pressure-tested with nitrogen to find the slightest leak. A vacuum is then pulled on the circuit before the refrigerant is released into it. The drain is connected and slopes toward the outlet, the thermostat is wired, and the airflow is adjusted. At the end, we take the time to show you how it works.

The role of the TXV expansion valve

A TXV-type valve measures the superheat at the coil outlet and opens or closes its passage accordingly. For you, this means a coil that works over its whole surface rather than only a portion of it, and steadier operation when the weather goes from cool to very hot.

Why efficiency ratings are not on the coil

A coil carries no efficiency rating of its own. The ratings belong to the matched system, identified by an AHRI number. When two contractors give you quotes, ask each for that number: it is the only way to compare on an equal basis. We confirm ours before placing the order.

A note from Trane: the R-410A coils in this family are intended for replacement, not for a new installation (COR-PSD012A-EN). We therefore look at what is already in place in your home.

The coil in a real home: three examples

First example, an enlarged country house in Saint-Eustache, on the North Shore: the original, narrow furnace was kept during the renovation, but two bedrooms were added. The load calculation now exceeds what a small coil allows; the width, however, has not changed. This model solves the equation without moving the furnace.

Second example, a semi-detached home in Longueuil whose basement was finished as a family room. The furnace is wedged between a wall and a hot-water boiler. The plenum cannot be widened. The narrow cabinet fits in, and the 22-1/2 in height finds its place under the exposed joists, after verification.

Third example, a Laval bungalow that has always been heated with electricity. The owner wants to cut the winter bill without redoing the ducts. The add-on heat pump connected to this coil keeps the electric furnace in reserve and calls on it only when the cold turns biting.

What a good load calculation looks at

We never choose a size on floor area alone. The calculation takes into account the insulation of the walls and attic, the quality of the windows, exposure to the afternoon sun, air leakage and the number of people living in the home. A large, well-insulated home may need less than a smaller but poorly insulated one.

When the results fall between two sizes, we lay out both options with their consequences, and you make the call.

Heat pump or air conditioner?

Paired with a heat pump, this coil heats in winter and cools in summer. Paired with an air conditioner, it only cools. In both cases, it goes onto your furnace and reuses the existing ducts. If you keep the furnace, it takes over below the temperature threshold we set together.

Financial assistance

Hydro-Québec incentives are based on the complete system. We check the match on the official list according to the installation date, then tell you clearly what applies, without promising an amount.

Points to check before buying

  • Does the existing system really use R-410A?
  • Is the furnace 14-1/2 in wide, or is a transition needed?
  • Is there 22-1/2 in of vertical clearance for the cabinet?
  • Can the blower deliver the airflow of the system?

A family business in Montreal

AirGreen is a heating and cooling company based in Montreal for more than fifteen years, working under RBQ licence 5645-9605-01. Trane, for its part, is a Trane Technologies brand.

Take the next step

Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Trane system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The 4TXCA032RS3 sits in the plenum of a furnace or air handler. Connected to a matching Trane outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Trane outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-410A refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerTrane
Model4TXCA032RS3
TypeCased evaporator coil
Line4TXC
Nominal size1.5 to 3 tons (36,000 BTU/h)
RefrigerantR-410A
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D14-1/2 × 22-1/2 × 21-1/2 in
Net weight41 lb
Model number4TXCA032RS3
03 · Before installing

What to know before installing

  • R-410A refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 14-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
TRANE
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-410A and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 3-ton Trane coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.