YORK CTF42C5CES1 Evaporator A-Coil | 3.5 Tons
The York CTF42C5CES1 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF42C5CES1
514 316-2973 · sales@airgreen.ca
Quick facts
CTF42C5CES1: the 3.5-ton York coil, the most compact of the group at 21 in wide
Of the four York CTF coils we compare here, this is the only one rated at 3.5 tons. The other three step up to 4 tons. If your home sits comfortably on one or two floors, without a large open-plan space, this is often the right starting point for a conversation about a central heat pump.
The CTF42C5CES1 is an A-shaped evaporator coil, supplied cased, that runs on R-454B refrigerant. We install it for customers in Montreal, Laval, Longueuil, the North Shore and the South Shore.
What an evaporator coil does, in plain terms
Picture the cold glass of an iced water in summer: warm room air cools against it and leaves water on the glass. The coil does the same thing on a much larger scale, inside the plenum of your furnace. Refrigerant arrives from the outdoor unit, evaporates in the tubes and absorbs heat from the air moved by the blower. The cooled air goes back out through the ducts; the moisture condenses and runs off to the drain.
With a heat pump outside, the cycle can be reversed. In winter, the refrigerant then carries heat into the house, and the furnace stays in reserve for the coldest days.
Where it fits: 3.5 tons, or 42,000 BTU/h nominal
The 42,000 BTU/h figure is a nominal size, a capacity label used to match the coil with the outdoor unit. On its own, it does not tell you whether the house will be comfortable. What counts is the real heat loss of the building envelope, the quality of the ductwork and the blower’s ability to move the air required. That is why we visit your home first, tape measure in hand, before suggesting a size.
A coil that is too big for a compact house does not bring more comfort. It tends to run in short cycles and leave the air more humid. A 3.5-ton size therefore suits mid-sized homes whose ducts do not serve a long string of rooms.
A spec sheet you can read in a minute
- cased, A-coil from the CTF range;
- 21 in wide, 25 in high, net weight of 52 lb;
- 3/8 in liquid line connection and 7/8 in suction line connection;
- TXV metering;
- nominal airflow of 1,400 CFM;
- upflow or downflow installation, depending on the furnace;
- 10-year limited parts warranty from the manufacturer.
The 25 in height is the lowest of the four models. The CTF42C5CES1 therefore slips more easily into a mechanical room where the clearance above the furnace is tight, which we measure before confirming anything.
Built-in safety for R-454B
R-454B is classed A2L: it is hard to ignite, but regulations and the manufacturer call for monitoring. York has therefore mounted a factory sensor on the coil plate. This sensor is linked to the RDS control board. If the concentration approaches the set threshold (15% of the LFL), the call to the compressor is cut off and the indoor fan starts to dilute the air. There is no accessory to add: the protection is already in the coil.
This 3.5-ton coil next to its three neighbours
Here is how we help customers decide between the models in the series, using only the published data:
- CTF42C5CES1 (this one): 3.5 tons, 21 in wide, TXV metering, R-454B.
- CTF48C5AFS1: 4 tons, 21 in wide, same metering and same refrigerant. Same width as ours, higher capacity.
- CTF48C5CFS1: 4 tons, 21 in, with a matched outdoor unit listed, the HH836E2S11.
- CTF48D5CFS1: 4 tons, 24-1/2 in wide, for a wider furnace.
The practical conclusion: if your furnace is 21 in wide and the house is mid-sized, the 3.5-ton coil is the natural choice. If the house is larger, the 4-ton size is the one to look at, at the same 21 in width. And if the furnace is wider, think of the CTF48D5CFS1.
A concrete example
Take a family in Longueuil living in a mid-sized two-storey home, heated with electricity from an old furnace and with no air conditioning. They want to stop installing window air conditioners and cut their winter bill. The 3.5-ton coil goes on the existing furnace, a York heat pump of the same capacity is connected to it, and in a single project the house gets cool air in summer and more economical base heating in winter.
Another case, more common than you might think: a homeowner in Laval whose central air conditioner is at the end of its life. Because it runs on a different refrigerant, the coil cannot simply be swapped on its own; we install the coil and the outdoor unit together, designed to work with the same fluid.
Outdoor unit match and efficiency ratings
This coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 values belong to the certified system, meaning a specific combination of coil and outdoor unit linked by an AHRI number. For this model, we confirm the AHRI number in the directory before ordering, so that the ratings shown in your quote are the ones you will actually get.
York publishes its matches with the HH8 heat pump on R-454B, with a variable-speed compressor. The liquid line is 3/8 in, and larger diameters may be required when the distance between the units is long. We take all of this into account in the installation plan.
To check before you buy
- The coil is matched to an outdoor unit that uses the same refrigerant and is installed at the same time.
- The 21 in width must match your furnace; if not, we build an insulated transition on site.
- The blower must be able to deliver the system’s airflow, otherwise ice can form on the coil.
- The published ratings apply to the certified match, not to the coil taken alone.
How we run the job
A visit is used first to measure the furnace, check the blower, examine the electrical panel and locate the return ducts. Then come:
- installing the coil in the plenum and sealing the duct connections;
- installing the outdoor unit on a pad or bracket, the brazed piping, the nitrogen pressure test and the evacuation;
- connecting the condensate drain and the thermostat;
- commissioning, setting the airflow and explaining how it all works, at your home, with you.
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under our RBQ licence 5645-9605-01.
About York
York is a residential brand of Johnson Controls, distributed in Quebec by Groupe Master. It makes central heat pumps, furnaces and the coils that go with them. The CTF, CTM and CTU coils on R-454B include the leak detection required for this refrigerant.
Incentives
Eligibility for Hydro-Québec programs depends on the complete system, never on the coil alone. At the time of the quote, we check the match against the official list for your installation date, then tell you clearly what applies to your project.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF42C5CES1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching York outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.