YORK CTF48C5CFS1 Evaporator A-Coil | 4 Tons
The York CTF48C5CFS1 4-ton R-454B cased coil sits on your furnace and, matched with the York HH836E2S11 outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF48C5CFS1
514 316-2973 · sales@airgreen.ca
Quick facts
CTF48C5CFS1: a 4-ton York coil that comes with its certified match, the HH836E2S11
Most central heat pump quotes read like a menu without prices: a coil, a unit, a few numbers, and little way to check them. The CTF48C5CFS1 has one distinguishing feature: among the four York CTF coils in this series, it is the only one for which we list a matched outdoor unit, the HH836E2S11, and a system AHRI number, 214606577.
It is a 4-ton (48,000 BTU/h nominal) A-shaped evaporator coil, cased, running on R-454B refrigerant. It is installed in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, on top of a furnace or a blower cabinet.
The system before the coil
A coil neither heats nor cools by itself. What matters for your comfort and your bill is the combination with the outdoor unit. For this one, York publishes the following values for the matched system:
- outdoor unit: HH836E2S11;
- AHRI number: 214606577;
- cooling: 31,600 BTU/h;
- heating: 30,800 BTU/h at 47 °F;
- system SEER2 / HSPF2 ratings: 15.2 / 8.5.
Note that the published system capacity is lower than the coil’s nominal size of 48,000 BTU/h. This is not an error: the 4-ton label refers to the size of the coil, while the certified capacity comes from the pairing of coil and outdoor unit. It is one more reason to read the AHRI number rather than the size alone.
How to use the AHRI number
If you receive two quotes for the same house, ask each one for the AHRI number of the proposed system. Enter it in the public AHRI directory: you will see the certified ratings, with no advertising. A serious contractor should be able to give it to you before you sign. For the CTF48C5CFS1 matched with the HH836E2S11, that number is 214606577.
It is also this number that is used to check eligibility for incentive programs.
What is in the box and on the furnace
The coil comes in an insulated cabinet, ready to be set on the plenum. Its dimensions are 21 in wide by 27 in high, for a net weight of 55 lb. The connections are 3/8 in on the liquid side and 7/8 in on the suction side. The nominal airflow is 1,600 CFM, and the metering is of the TXV type. Upflow or downflow installation, as suits the furnace.
The manufacturer’s warranty covers parts and lasts 10 years (limited warranty). York’s brochure sets out the conditions.
A built-in alarm for the refrigerant
R-454B calls for leak monitoring. York has therefore fixed an A2L-type detector to the coil plate at the factory, linked to the RDS board. When the detected level reaches 15% of the lower flammability limit, the compressor stops being called and the indoor blower starts. You have nothing extra to order.
Choosing between this model and its three siblings
Here is the grid we use at the counter:
- are you looking for a system whose ratings are already published? The CTF48C5CFS1 with the HH836E2S11 is the one that offers them;
- does your house need less capacity? The CTF42C5CES1 is a 3.5-ton coil of the same width, 21 in;
- is your furnace the same width as this one and you are aiming for 4 tons with no listed match? The CTF48C5AFS1 offers the same width and the same metering;
- is the furnace wider? The CTF48D5CFS1 measures 24-1/2 in.
All of them stay on R-454B and TXV metering.
Who it is for in Greater Montreal
This setup is mainly for owners of large multi-storey homes, bungalows with a finished basement or semi-detached homes whose ducts serve many rooms, and who want to turn an electric furnace into a central heat pump. It is also for those whose old central air conditioner is reaching the end of its life and who prefer to start over with a new, matched system.
What a heat pump changes at home
An electric furnace converts each kilowatt-hour into an equal amount of heat. A heat pump moves heat from outdoors to indoors and, in mild weather, delivers two to three times more heat than the electricity it uses. As the cold intensifies, this efficiency drops; the furnace then takes over at a threshold that we set with you.
In summer, the same coil replaces window air conditioners. A single outdoor unit, cool air in every room and a drier house: the humid heat of July becomes more bearable.
To check before choosing
- the match of the coil with a unit that uses the same refrigerant and is installed at the same time;
- the fit between the coil’s width and the furnace’s;
- the blower’s ability to deliver the airflow wanted;
- the fact that the displayed ratings apply to the complete system.
The job, step by step
We start by measuring the furnace and checking the blower and the electrical panel. Next comes installing the coil in the plenum, with a transition built on site if necessary, and sealing the connections. The outdoor unit is installed on a pad or bracket; the piping is brazed, tested with nitrogen and evacuated. We connect the condensate drain and the thermostat, then put the system into service while setting the airflow.
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01.
Three questions to ask before signing
First, which AHRI number corresponds to the proposed system? For this one, you already have the answer: 214606577. Second, does the furnace have the right width and blower? We check this at your home, with the tape measure and the instruments. Third, what does the warranty cover? The manufacturer offers a 10-year limited parts warranty; York’s brochure details the conditions, and we are happy to show it to you.
What this match means in practice
A system with published ratings lets you compare quotes on a common basis. When a competitor proposes another brand or another outdoor unit, you can put the AHRI numbers side by side, read the certified capacities for cooling and heating, and judge whether the price difference matches a difference in performance. We encourage this approach: an informed customer chooses more calmly, and our installations stand up to it very well.
LogisVert incentive
The matched York system appears on Hydro-Québec’s list of eligible heat pumps. The amount varies with the installation date and your situation. We check it on the official list at the time of the quote, then build the application with you.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF48C5CFS1 sits in the plenum of a furnace or air handler. Connected to the York HH836E2S11 outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the York HH836E2S11 outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
