YORK CTF48C5AFS1 Evaporator A-Coil | 4 Tons
The York CTF48C5AFS1 4-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF48C5AFS1
514 316-2973 · sales@airgreen.ca
Quick facts
Multi-storey home with a finished basement: the 4-ton York CTF48C5AFS1 coil
When the ducts serve three levels, the basement is finished as a family room and the July sun hits the west-facing front, a small size runs out of breath. In this kind of home, in Montreal as in Laval or Longueuil, the CTF48C5AFS1 finds its place. It is a York evaporator coil of 4 tons (48,000 BTU/h nominal), an A-coil, cased, running on R-454B refrigerant.
We also install it on the North Shore and the South Shore, wherever an existing furnace can serve as the base for a central system.
Why 4 tons rather than 3.5
A bigger size does not automatically mean more comfort. It means more heat-exchange surface and a larger airflow. Here, the nominal airflow is 1,600 CFM, higher than that of the 3.5-ton model in the same series. The air therefore passes through a coil designed for a larger volume, which suits homes where many vents must be supplied.
This requirement carries over to the furnace: its blower must actually deliver that airflow. With a weak blower, dirty filters or a return that is too narrow, the coil cools poorly or even frosts up. We test this during the visit, before promising anything.
Reading the dimensions like an installer
The CTF48C5AFS1 measures 21 in wide by 27 in high, and weighs 55 lb. Compared with the CTF42C5CES1, the width is identical; it is the height that gains two inches, and the weight three pounds. In a tight mechanical room, that height difference can make all the difference, which is why measuring the clearance above the furnace matters.
The connections are 3/8 in for the liquid line and 7/8 in for the suction line. Metering is handled by a TXV, a valve that doses the refrigerant according to the load. The manufacturer allows upflow or downflow installation.
What changes when you add a heat pump
With a central air conditioner alone, the coil only cools. Paired with a York heat pump of the same capacity, it also becomes a heating component: in winter, the refrigerant carries heat from outdoors into the house. The furnace keeps its blower, its filters and its role as backup heat during the coldest periods, according to a temperature threshold that we set together.
For a large home heated with electricity, this is often where the difference on the bill is made: the heat moved by the heat pump costs less than heat produced directly by a resistance element.
This 4-ton coil among its siblings
Three of the four models in the series are 4 tons, which can be confusing. Here is what sets them apart, based on the manufacturer data we have on hand:
- CTF48C5AFS1 (this page): 4 tons, 21 in wide, TXV, R-454B. No matched outdoor unit is listed here; we confirm it with you before the order.
- CTF48C5CFS1: same basic dimensions, but the HH836E2S11 outdoor unit is published for it with an AHRI number.
- CTF48D5CFS1: also 4 tons, at 24-1/2 in wide, for wider furnaces.
- CTF42C5CES1: 3.5 tons, 21 in wide, for a more modest home.
If your furnace is 21 in wide and the house is large, you are really choosing between this model and the CTF48C5CFS1. In both cases, the decision comes down to the match: which outdoor unit, and which AHRI number goes in the quote.
Protection against refrigerant leaks
R-454B belongs to the A2L category. York responds by installing a sensor on the coil plate from the factory, wired to the RDS control board. As soon as detection exceeds 15% of the LFL, the call to the compressor stops and the indoor blower starts. The manufacturer’s manual describes exactly how this device works.
Outdoor unit match and efficiency ratings
A coil on its own has no SEER2, EER2 or HSPF2 rating. These values describe a complete system, certified under an AHRI number that links the coil and the outdoor unit. That number is what lets you compare two quotes honestly, and it is the one that incentive programs look up.
York publishes several matches with its HH8 heat pump on R-454B, with a variable-speed compressor. Most are certified for cold climates. We check in the directory that the proposed match appears among the certified combinations, then we write it into the quote.
Spec sheet summary
- model: CTF48C5AFS1, CTF range, cased coil;
- size: 4 tons, or 48,000 BTU/h;
- refrigerant: R-454B;
- dimensions: 21 × 27 in, net weight of 55 lb;
- nominal airflow: 1,600 CFM;
- 10-year limited parts warranty, provided by York.
Our work at your home
At the first appointment, we measure the furnace, assess the blower and look at the electrical panel. If the coil’s width differs from the furnace’s, we build an insulated transition on site. Then we install the coil in the plenum, seal the connections, install the outdoor unit, braze the piping, run the nitrogen test and pull a vacuum. The condensate drain and the thermostat are connected next; commissioning includes setting the airflow and an explanation given on site.
Behind these steps stands a family-run heating and cooling company based in Montreal for more than fifteen years, working under RBQ licence 5645-9605-01.
Common questions
Can I keep my current air conditioner? In general, no: the coil runs on R-454B and is matched to the outdoor unit specified by the manufacturer. We install the full set.
Is my furnace still useful? Yes, it keeps its blower and takes over when it gets really cold.
Three scenarios where this model is the right call
The expanded cottage. An addition at the back, a games room in the basement: the original house, served by a small air conditioner, is no longer enough. The 4-ton coil, with its blower verified, absorbs the extra load without having to redo the duct network.
The home that has always been electrically heated. The baseboards or the old furnace do their job, but the winter bill weighs heavily. By adding the heat pump, the furnace becomes backup heat rather than the main source.
The forced replacement. A neighbour’s central air conditioner has just died in the middle of a heat wave; you would rather not wait for the same fate. It is better to plan the complete system in the spring, with time to compare AHRI numbers, than to choose in a rush on a heat-wave day.
What we will give you in writing
The quote names the coil model, the selected outdoor unit, the AHRI number of the match once confirmed, the description of the work and the items included. If the furnace requires a transition or the electrical panel needs a modification, that is also in the document, so that the final invoice holds no unpleasant surprises.
Incentives
Hydro-Québec programs look at the matched system, not the coil taken in isolation. We consult the official list for your installation date and show you what applies to your file.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF48C5AFS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching York outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 21 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.