YORK CTF48D5CFS1 Evaporator A-Coil | 4 Tons
The York CTF48D5CFS1 4-ton R-454B cased coil sits on your furnace and, matched with a matching York outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCTF48D5CFS1
514 316-2973 · sales@airgreen.ca
Quick facts
Wide furnace, wide coil: the 4-ton, 24-1/2 in York CTF48D5CFS1
On a job site, the first question is almost never capacity. It is width. A large furnace, a blower cabinet roomier than average: if the coil does not line up with the plenum, everything gets complicated. The CTF48D5CFS1 is our York model for those cases. It measures 24-1/2 in wide, while the other three coils in the series stay at 21 in.
It is an A-shaped evaporator coil, cased, of 4 tons (48,000 BTU/h nominal), that runs on R-454B. Our team installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Take the tape measure first
Measure the inside width of your plenum, or better, let us do it. If it is close to 24-1/2 in, this model lines up naturally. If it is 21 in, the CTF48C5AFS1 or the CTF48C5CFS1 would be the better fit, offering the same nominal capacity in a narrower size.
And what if the plenum matches none of the models exactly? We build an insulated transition on site. It is routine work, but the smaller the gap, the cleaner the installation.
The dimensions of this model, one by one
- width: 24-1/2 in;
- height: 27 in;
- net weight: 58 lb, three pounds more than the 21 in version;
- liquid line connection: 3/8 in;
- suction line connection: 7/8 in.
This extra width gives the incoming air more face area. For the same nominal airflow of 1,600 CFM, the circulation is spread over a more generous surface. We take care not to promise a specific gain, however: the manufacturer does not publish one for this model.
The same comfort engine as its siblings
Apart from the width and the weight, the basic features are alike: 4-ton size, TXV metering, R-454B refrigerant, insulated cabinet, upflow or downflow installation. The choice is therefore made on the layout of your furnace rather than on the technology.
Comparing in three lines
- CTF42C5CES1: 3.5 tons, 21 in. For an average home.
- CTF48C5AFS1 and CTF48C5CFS1: 4 tons, 21 in. The second lists a matched outdoor unit, the HH836E2S11.
- CTF48D5CFS1 (here): 4 tons, 24-1/2 in, no matched unit listed on this page; we confirm it with the AHRI number before ordering.
How the coil works in your furnace
The coil is installed in the plenum, in the path of the air. In summer, the refrigerant evaporates in its tubes and removes heat from the air passing through; the condensation is collected in a pan and sent to the drain. With a heat pump outside, the cycle reverses in winter and heat from outdoors is transferred into the air of the house. The furnace keeps its blower, its filters and its role as backup when the temperature falls below the agreed threshold.
This approach respects the existing duct network. No walls are drilled and no distribution is redone: we replace what makes the cold or the heat.
Leak detection from the factory
The coil is delivered with an A2L sensor already fixed to the plate, which York’s manual associates with the RDS control board. If the reading exceeds 15% of the LFL, the call to the compressor is cut and the indoor blower turns on. This is what makes R-454B acceptable in a standard residential system.
Efficiency: what we can say and what we cannot
A coil has no SEER2, EER2 or HSPF2 of its own. These ratings are tied to a certified system, with an AHRI number. For the CTF48D5CFS1, we look for the match with a York outdoor unit of the same capacity, consult the directory and write the truly certified ratings into the quote. We would rather promise nothing than announce a figure that does not apply to your installation.
York publishes its matches starting from the HH8 heat pump on R-454B, variable speed. The liquid lines are 3/8 in; for a long distance, larger diameters may be requested.
The CTF48D5CFS1 in the daily life of a large home
In a multi-storey home in Laval, a finished basement can stay cool while the upper floor is stifling, or the other way around. A 4-ton system with an adequate blower helps balance this. In the newer neighbourhoods of the South Shore or the North Shore, large furnaces are common: that is where the width of this coil makes the most sense.
In summer, a single outdoor unit replaces window air conditioners; in winter, the heat pump supplies most of the heating and the furnace serves as a supplement.
Before calling us, check this
- the coil is matched to an outdoor unit that uses the same refrigerant and is installed with it;
- the furnace width allows 24-1/2 in, or a reasonable transition;
- the blower can deliver the airflow needed;
- the published ratings belong to the certified match.
What our installation includes
We measure the furnace, check the blower and the electrical panel, install the coil in the plenum and seal the duct connections. The outdoor unit is mounted on a pad or bracket; the brazed piping undergoes a nitrogen pressure test before evacuation. The condensate drain and the thermostat are connected, then we set the airflow and show you how it works on site.
AirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01.
About York and the warranty
York is a Johnson Controls brand, distributed in Quebec by Groupe Master. The manufacturer offers a 10-year limited parts warranty on this coil.
The width mistakes we see most often
The first is ordering on capacity alone. Four tons, very well, but for which furnace size? The second is relying on an outside measurement of the cabinet: the plenum opening is what determines what the coil can receive. The third is neglecting vertical clearance, because the 27 in high cabinet must fit without cutting into access to the filters.
That is why our assessment visit begins with these measurements. We take the time to note every dimension, photograph the mechanical room and validate it all against the installation plan before placing the order.
What you will receive in the quote
A written document specifies the coil model, the selected outdoor unit, the AHRI number of the match once verified, the planned work and any adaptations, such as the plenum transition. You thus know, before signing, what is included and what could change the price.
Incentives
Hydro-Québec programs apply to the complete system. We check the match on the official list at the time of the quote and tell you what applies to your project.
Request your estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete York system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CTF48D5CFS1 sits in the plenum of a furnace or air handler. Connected to a matching York outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching York outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
YORKSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton York coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.