ELIOS E-MULTI 2-Head Heat Pump + 48,000 BTU Compressor | Longueuil

In stock
SKU: EXHSA4862AV1-2
48,000BTU/h · 2 heads
−25 °Cheats down to
$4,416LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientOptional Wi-FiR-454BUp to 6 heads
Areas
Talk to a technician · 514 316-2973
Outdoor unit EXHSA4862AV1Possible indoor models EWHMA06C2AS1, EWHMA09C2AS1, EWHMA12C2AS1, EWHMA18C2AS1, EWHMA24C2AS1, EWHMA33C2AS1AHRI 216046645· ENERGY STAR 3799033
In short

The ELIOS E-Multi 48 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 36,800 BTU/h at −8 °C, heats down to −25 °C and qualifies for a $4,416 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 82 multi-zone systems of 48,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 383617AHRI 216046645LogisVert · October 1, 2026
+Indoor head from 20 dB(A)Rank 6 (tied) of 78. Class median: 28 dB(A).
+COP 2.10 at −15 °CRank 12 (tied) of 71. Class median: 2.00.
!Good to know: 65 dB(A) outdoorsRank 56 of 82; class median: 64 dB(A).
36,800BTU/h certified at −8 °C
−25 °Cstill heating
2 → 6heads, on the same unit
2.4COP at −8 °C
$4,416LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

EXHSA4862AV1

Outdoor unit

One compressor for the whole house. It supplies up to 6 heads and modulates from 13,000 to 36,800 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
23
27,000BTU
234
36,000BTU
2345
48,000BTU
Here3456

ELIOS E-Multi 48 000 · 2 zones

36,800 BTU/h
at −8 °C
$4,416
LogisVert

Up to 6 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 75 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
13,000 → 55,000 BTU/h
-8 °C
12,000 → 36,800 BTU/h
-15 °C
10,000 → 36,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling21.3
Scale 1 – 30Median: 21.3
Rank 31 (tied) of 78 in its class.
HSPF2 · seasonal heating10.0
Scale 1 – 15Median: 10
Rank 27 (tied) of 78 in its class.
EER2 · cooling in peak heat11.7
Scale 1 – 20Median: 12
Rank 49 (tied) of 78 in its class.
COP at −15 °C2.1
Scale 0 – 4Median: 2
Rank 12 (tied) of 71 in its class.
ENERGY STAR Most EfficientCold climate · ID 3799033 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

36,800 BTU/h÷ 1,000 ×$120=$4,416

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 216046645). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 82 multi-zone systems of 48,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,416 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

52.48 in
EXHSA4862AV1Depth 16.34 in
37.48 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA  A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

20
44.7
65
28
64
20 dB(A)3040506070
20 Reference head, lowest speed44.7 Reference head, highest speed28 Class indoor median65 Outdoor unit64 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
13,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−25 °CColdest certified pointNEEP still lists 20,000 BTU/h at a COP of 1.20 at −13 °F.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTU · 4 tonsSheet
Certified cooling at 35 °C45,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)21.3AHRI
EER2 (instant cooling efficiency)11.7AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
HSPF2, region V (coldest)7.7NEEP
Heating
Capacity at +8.3 °C48,000 BTU/h · COP 3.6NEEP
Capacity at −8 °C36,800 BTU/h · COP 2.4NEEP
Capacity at −15 °C36,000 BTU/h · COP 2.1NEEP
Capacity at −25 °C (max.)20,000 BTU/h · COP 1.2NEEP
Modulation range13,000 – 36,800 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones6 ZonesSheet
Possible indoor modelsEWHMA06C2AS1, EWHMA09C2AS1, EWHMA12C2AS1, EWHMA18C2AS1, EWHMA24C2AS1, EWHMA33C2AS1Sheet
Combinations offered19 · 6+24 … 24+36Sheet
Indoor dimensions (W × D × H)31.57 × 7.87 × 11.61 inSheet
Vertical louversManualSheet
Horizontal louversAutoSheet
Airflow (reference head)383 CFMSheet
Indoor sound (reference head)20 – 44.7 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.48x16.34x52.48 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound65 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-454BSheet
Wi-FiOptionalSheet
Certifications and warranty
AHRI216046645AHRI
ENERGY STARYes · cold climate · ID 3799033ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$4,416LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 0 yrsSheet
AirGreen extended warrantyPossibleSheet
17 · Official brochures

The manufacturer’s documentation, as PDF.

18 · Description

Everything we have written about this system.

{start article}

ELIOS E-MULTI 2-Head Heat Pump + 48,000 BTU Compressor | Longueuil

A multi-zone solution designed for the residential and multi-unit realities of the South Shore

At AirGreen , we have been installing multi-zone HVAC systems in Longueuil and throughout the South Shore for many years. The ELIOS E-MULTI 2-head heat pump with a 48,000 BTU compressor is one of the configurations we recommend when the needs are clear: to efficiently heat and cool several distinct spaces, with precise zone control, while maintaining excellent energy efficiency even in extreme cold.

This type of system is suitable for single-family homes , plexes , condos , as well as small multi-unit buildings where the usual compromises of classic centralized systems are to be avoided.


A flexible, multi-zone architecture that is truly usable in the field

The heart of this configuration lies in a 48,000 BTU ELIOS E-MULTI outdoor unit , capable of powering up to 6 indoor units , even though the version shown here is configured with 2 active zones . This reserve capacity offers a tangible advantage:
• improved heating stability
• fewer short cycles
• future scalability without compressor replacement

In practice, in Longueuil, we often see this system installed in buildings where an extension, a finished basement or a conversion into additional housing is planned in the medium term.

Extended compatibility of indoor units

The system accepts several formats:

  • EMC wall units (6,000 to 24,000 BTU)

  • ducted units

  • 1-channel or 4-channel cassettes

  • consoles

This diversity makes it possible to adapt the HVAC design to the actual architecture of the building, without imposing a single type of air emitter.


Heating efficiency: a concrete response to Longueuil's climate

One of the most important criteria for our customers remains the heating capacity in cold weather .
This ELIOS model is designed to operate down to -25°C , with measured and consistent performance.

Key data for the 48,000 BTU model:

  • Rated capacity : 48,000 BTU

  • Power at -8°C : ~34,000 BTU

  • Power at -15°C : ~36,000 BTU

  • COP at -8 °C : 3.9

  • ENERGY STAR® Certification – Cold Climate

In practice, this means a real reduction in the use of auxiliary heating , even during the prolonged cold spells that regularly affect the South Shore of Montreal .


Energy efficiency and R-454B refrigerant: a choice for the future

The ELIOS E-MULTI heat pump uses R-454B refrigerant , known for:

  • a reduced global warming potential (GWP)

  • increased compliance with future environmental standards

  • improved volumetric efficiency

The performance indicators are solid:

  • SEER2 up to 21.3

  • High HSPF2 in multi-zone configuration

  • EER2 optimized for actual loads

For our customers in Longueuil, this translates into better-controlled electricity bills , particularly during periods of prolonged summer air conditioning.


Zone-based comfort management: an often underestimated daily advantage

Each zone operates independently. In practice, this allows:

  • to lower the temperature in unoccupied rooms

  • to adapt comfort according to sun exposure

  • to limit conflicts over adjustments in families or multiple dwellings

We regularly observe that this fine-tuning of comfort not only improves satisfaction, but also the overall lifespan of the system, because the machine works more intelligently.


Noise level: a critical point that has been controlled

In Longueuil's dense residential projects, noise is a real issue.

  • Outdoor unit : ~65 dB(A)

  • Indoor units : up to 20 dB(A) depending on the model and speed

During installation, AirGreen pays particular attention to:

  • the exact location of the compressor

  • vibration isolation

  • the configuration of the supports

These details make a tangible difference on a daily basis.


HVAC Installation in Longueuil: What We Do Differently at AirGreen

Beyond the product itself, the quality of HVAC installation determines 50% of the actual performance.
On this type of ELIOS E-MULTI system, our teams systematically take into account:

  • load calculation by zone

  • the exact length of piping

  • refrigeration balancing

  • future access for HVAC maintenance

We have installed similar configurations in Longueuil-East, Saint-Hubert, Greenfield Park and in several condominiums on the South Shore, with very positive feedback on the stability of winter heating.


LogisVert subsidy: a major financial lever

This heat pump is eligible for the LogisVert provincial subsidy , with an amount of up to $4,080 (updated November 2025).
We support our clients in Longueuil with:

  • validation of eligibility

  • AHRI number compliance

  • the preparation of the file

This often tips the decision in favor of a high-efficiency multi-zone system rather than a minimal solution.


Guarantee and peace of mind

Standard configuration:

  • Compressor : 10 years

  • Parts : 10 years

  • Labor : 0 years (extension possible)

Depending on the project, we offer tailored extended warranties , particularly relevant for income properties or long-term owner-occupiers.


For whom is this heat pump really suitable?

This model is particularly relevant if:

  • you have several spaces at different temperatures

  • You want a scalable system

  • You prioritize efficient electric heating

  • Your building is located in Longueuil or on the South Shore , with exposed winters

Conversely, for very small areas or a single open space, a different configuration might be more appropriate. This is precisely the type of analysis we conduct before each submission.


Why choose AirGreen for your ELIOS project in Longueuil?

We don't just sell equipment. We deliver a complete HVAC solution , designed to:

  • the local climate reality

  • the actual use of the building

  • long-term sustainability

Our approach is based on transparent pricing , experienced refrigeration technicians , and a strong local presence in Longueuil, Montreal, Laval, North Shore and South Shore.


Contact AirGreen for a precise evaluation of your project

Are you considering installing an ELIOS E-MULTI 2-head 48,000 BTU heat pump in Longueuil ?
Contact AirGreen for a detailed analysis, a clear estimate and complete support, from the subsidy to commissioning.

Telephone : 514-316-2973
Email : sales@airgreen.ca

19 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,800 BTU/h at −8 °C, 36,000 at −15 °C.

How many heads can I connect?

Up to 6 on this outdoor unit. This product is configured for 2 heads.

Can I mix head sizes?

Yes. The “Zones” menu offers 19 combinations, from 6+24 to 24+36 (in thousands of BTU). Each head is sized for its room.

How much is the LogisVert grant?

$4,416 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3799033. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 20 dB(A). Outdoors, 65 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts; labour is not included by the manufacturer. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,416AHRI 216046645 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 383617 (AHRI 216046645): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 3799033.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.