PTAC Heat Pump DURASTAR | 12,000 BTU - R410A

In stock
SKU: DRPTHP12Y41G1A
12,000 BTU/h actual450 to 550 sq ftHeat pump + 3.5 kW max
Talk to an HVAC technician · 514 316-2973
Heat pump and a heater of up to 3.5 kWStandard 42 × 16 in sleeve10-year compressor warranty
01 · Your room

Is it the right size for this room?

Durastar publishes a 450 to 550 sq ft range for this unit. Choose your room's area.

It's the right size.

For a 450 to 550 sq ft room, this is the range Durastar publishes for this unit: 12,000 BTU/h of cooling, 10,800 BTU/h of heat-pump heating and a heater of up to 3,535 W when the cold calls for it.

Application range published by Durastar for each capacity in the lineup. Our estimator confirms the exact area on site.

02 · Performance

What it does, in numbers

12,000BTU/h
Cooling at 230 V11,800 at 208 V, the supply in many buildings.
10,800BTU/h
Heat-pump heatingRated at 8 °C (47 °F).
3,535W
Maximum electric heater2,900 W at 208 V. It heats when the heat pump can no longer keep up.
11.6EER
Cooling efficiencyThat's 1,034 W drawn at 230 V for 12,000 BTU/h.
What it costs per yearTypical 500 sq ft room · Rate D
Summer · cooling

$23.04

Cooling, all summer

Less than a 60 W light bulb

Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.

Winter · heating

≈$369

Heating, all winter

≈ $29 less than baseboard heaters

Heat pump8 °C and warmer outside · 10% of the heat≈ $12
Electric heaterBelow 8 °C · 90% of the heat≈ $357

Typical 500 sq ft room with one exterior wall, in Montréal: 3,571 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Durastar rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.

≈ $392 for the year, before tax. Winter is 94% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $14.61.

$0.12/h
One hour of cooling
$0.10/h
One hour of heat-pump heating
$0.39/h
One hour on the 3.5 kW heater

Capacities and currents: Durastar PTAC/PTHP R-410A submittal, form V1.0_12.22 (December 2022). Power draw: 1,034 W in cooling (12,000 BTU/h ÷ EER 11.6), 930 W in heat-pump mode, 3,535 W on the 3.5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

12,000What it really delivers in cooling

The name says 12,000 BTU: that's the unit's size class. Durastar publishes 12,000 BTU/h at 230 V, and 11,800 at 208 V, the supply in many buildings.

3,535 WThe heater that takes over

The "G" in DRPTHP12Y41G1A means a 3.5 kW heater: 3,535 W (10,900 BTU/h) at 230 V, 2,900 W at 208 V, on the 6-20P plug of the LCDI cord supplied. It heats when the heat pump can no longer keep up.

3.4The COP published at 8 °C

Durastar publishes a heat-pump COP of 3.4: 10,800 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.4 in heat, against 1 for the heater or a baseboard.

51 dBThe noise at low speed

51 dB(A) at low speed, 51.4 at high speed, as published by Durastar. In a bedroom, that's the number that decides the complaints: the unit runs at night, two metres from the bed.

2.81Pints of water it removes per hour

The dehumidification Durastar publishes in cooling mode: 2.81 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.

62 cfmFresh air through the vent

With the vent open, Durastar publishes 62 cfm of outside air at high speed. Close it to keep all the heat or the cool air in the room.

0 °CRoom freeze protection

In an unoccupied room, Durastar provides automatic freeze protection at 32 °F (0 °C): the fan and the heater restart on their own.

Replacement

It fits the standard wall sleeve

Durastar designs this PTAC for the standard 42 × 16 in wall sleeve; the sleeve and grille are sold separately. Our estimator checks the ones in place before ordering.

42 × 16
inches, standard size
04 · Installation

What it needs on site

42 × 16 in sleeveIndustry-standard size
14 ¾ in sleeveDRPTACWS foldable sleeve
Dedicated 20 A circuitFor the 3.5 kW heater (NEMA 6-20P plug)
115.7 lbUnit weight

In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.

Complete spec sheetData and cited sources
Model
DRPTHP12Y41G1A
Cooling capacity (208/230 V)
11,800 / 12,000 BTU/h
Heating capacity, heat pump (208/230 V)
10,500 / 10,800 BTU/h
Electric heater
3.5 kW (2,900 / 3,535 W at 208/230 V)
EER
11.6
COP (heat pump, 8 °C)
3.4
Current — cooling (208/230 V)
4.89 / 4.5 A
Current — heat-pump heating (208/230 V)
4.36 / 4.05 A
Power — cooling (208/230 V)
1,020 / 1,035 W
Power — heat pump (230 V)
930 W
Airflow (low/high)
320 / 398 cfm
Sound level (low/high)
51 / 51.4 dB(A)
Dehumidification
2.81 pints/h
Published cooling area
450 to 550 sq ft
Dimensions
42 × 21 × 16 in (W × D × H)
Net weight
115.7 lb
Refrigerant
R-410A · 31.39 oz
Power supply
208/230 V · 1 ph · 60 Hz
Spec sheet (French)
PDF
Spec sheet (English)
PDF

All values: Durastar PTAC/PTHP R-410A submittal, form V1.0_12.22 (December 2022). Operating cost: cooling at 1,034 W for 200 h per summer; heating estimated for a typical 500 sq ft room (3,571 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The neighbouring models

Talk to an HVAC technician before you choose

We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.

L'été d'une chambre louée à la session, réglé par celui qui l'occupe

Dans une résidence étudiante de Repentigny, les unités changent d'occupant à chaque session et personne ne reste assez longtemps pour apprendre un système compliqué. Quand le conseil d'administration a revu ses règles sur les appareils visibles depuis la rue, la façade est devenue intouchable. La Thermopompe PTAC DURASTAR | 12 000 BTU - R410A répond aux deux contraintes : rien en saillie, et une commande à même le caisson.

DuraStar ne publie pas de certificat AHRI pour cet appareil ; les valeurs ci-dessous sont celles de sa fiche technique. Ce monobloc ne fait pas partie des appareils visés par la subvention thermopompes efficaces d'Hydro-Québec, d'où le 0 $ de la fiche.

Ce qui est mesuré, et ce qui ne l'est pas

  • Capacité nominale : 12 000 BTU/h
  • Réfrigérant : R-410A
  • Alimentation : 220 V, sur circuit dédié
  • Niveau sonore intérieur : 51,0 et 51,4 dB(A)
  • Caisson : 42 x 21 x 16 po, modèle DRPTHP12Y41G1A

Le confort d'été, sans promesse sur le chauffage

Ce que la fiche documente concerne la belle saison, et c'est là que l'appareil se juge : 12 000 BTU/h pour une unité d'environ 650 pieds carrés selon notre règle d'environ 18 000 BTU/h par 1 000 pieds carrés, ajustée selon l'isolation et la fenestration. L'appareil inverse aussi son cycle pour chauffer, mais DuraStar ne publie aucune capacité de chauffage : nous n'en annonçons pas, et le chauffage de l'immeuble reste la référence l'hiver.

Une unité d'essai avant de commander les autres

L'ouverture type et le manchon posé de niveau

Les unités étant identiques, la première pose sert de gabarit. Nous coupons à l'empreinte du caisson, 42 x 21 x 16 po, avec un linteau si un montant porteur est interrompu, puis nous posons le manchon mural de niveau sur la largeur avec sa pente vers l'extérieur. La grille extérieure vient au-dessus de la ligne de neige, alignée d'une unité à l'autre pour que la façade reste régulière.

Les essais avant la remise des clés

Sur l'unité d'essai, nous vérifions l'écoulement du condensat sous charge, l'étanchéité du pourtour, la prise 220 V, le cordon, le passage d'un mode à l'autre et le calage du caisson. Ce relevé devient la fiche de référence des unités suivantes.

Ce qu'il faut expliquer au locataire

  • Un délai de trois minutes au redémarrage protège le compresseur.
  • De la vapeur blanche sort de la grille en mode chauffage : c'est un dégivrage, il se termine seul.
  • De l'eau s'écoule côté extérieur par temps humide ; c'est le condensat.

Une odeur de brûlé, un disjoncteur qui saute, un code d'erreur récurrent ou de l'eau côté logement commandent l'arrêt et un appel au service. Le filtre se nettoie aux deux semaines et un entretien CVAC annuel reprend serpentins, écoulement et raccords ; notre service de nettoyage passe l'immeuble entre deux sessions.

AirGreen, avant de commander la série complète

Entreprise familiale de Montréal depuis plus de quinze ans, AirGreen dessert Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud, avec les licences RBQ en ventilation, en réfrigération et en électricité. L'évaluation est gratuite et la soumission remise par écrit, sans signature demandée sur place.

Planifiez votre estimation gratuite pour la Thermopompe PTAC DURASTAR | 12 000 BTU - R410A. Nous posons une unité d'essai, documentons l'ouverture type et vous remettons un devis pour le reste de l'immeuble.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.