PTAC Heat Pump DURASTAR | 15,000 BTU 5 kW - R32

In stock
SKU: DRPTHP15Y32501A
14,700 BTU/h actual550 to 700 sq ftHeat pump + 5 kW max
Talk to an HVAC technician · 514 316-2973
Heat pump and a heater of up to 5 kWStandard 42 × 16 in sleeve10-year compressor warranty
01 · Your room

Is it the right size for this room?

Durastar publishes a 550 to 700 sq ft range for this unit. Choose your room's area.

It's the right size.

For a 550 to 650 sq ft room, this is the range Durastar publishes for this unit: 14,700 BTU/h of cooling, 13,500 BTU/h of heat-pump heating and a heater of up to 5,000 W when the cold calls for it.

Application range published by Durastar for each capacity in the lineup. Our estimator confirms the exact area on site.

02 · Performance

What it does, in numbers

14,700BTU/h
Cooling at 230 V14,500 at 208 V, the supply in many buildings.
13,500BTU/h
Heat-pump heatingRated at 8 °C (47 °F).
5,000W
Maximum electric heater4,100 W at 208 V. It heats when the heat pump can no longer keep up.
10.6EER
Cooling efficiencyThat's 1,387 W drawn at 230 V for 14,700 BTU/h.
What it costs per yearTypical 625 sq ft room · Rate D
Summer · cooling

$30.91

Cooling, all summer

Less than a 60 W light bulb

Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.

Winter · heating

≈$461

Heating, all winter

≈ $36 less than baseboard heaters

Heat pump8 °C and warmer outside · 10% of the heat≈ $15
Electric heaterBelow 8 °C · 90% of the heat≈ $446

Typical 625 sq ft room with one exterior wall, in Montréal: 4,464 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Durastar rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.

≈ $492 for the year, before tax. Winter is 94% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $19.60.

$0.15/h
One hour of cooling
$0.13/h
One hour of heat-pump heating
$0.56/h
One hour on the 5 kW heater

Capacities and currents: Durastar PTAC/PTHP R-32 submittal, form V1.1_0324 (March 2024). Power draw: 1,387 W in cooling (14,700 BTU/h ÷ EER 10.6), 1,170 W in heat-pump mode, 5,000 W on the 5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.

03 · Good to know

What you should know about this one

Published, verifiable facts, not brochure claims.

14,700What it really delivers in cooling

The name says 15,000 BTU: that's the unit's size class. Durastar publishes 14,700 BTU/h at 230 V, and 14,500 at 208 V, the supply in many buildings. Better to read it here than on the spec sheet after installation.

5,000 WThe heater that takes over

The "50" in DRPTHP15Y32501A means a 5.0 kW heater: 5,000 W (15,000 BTU/h) at 230 V, 4,100 W at 208 V, on the 6-30P plug of the LCDI cord supplied. It heats when the heat pump can no longer keep up.

3.2The COP published at 8 °C

Durastar publishes a heat-pump COP of 3.2: 13,500 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.2 in heat, against 1 for the heater or a baseboard.

4 °CBelow 4 °C, the heater takes over

Durastar's manual states it is normal for the heat pump not to run below 40 °F (4 °C) outside: the heater then heats the room. The two never run at the same time.

52.5 dBThe noise at low speed

52.5 dB(A) at low speed, 53 at high speed, as published by Durastar. In a bedroom, that's the number that decides the complaints: the unit runs at night, two metres from the bed.

4.3Pints of water it removes per hour

The dehumidification Durastar publishes in cooling mode: 4.3 pints per hour. It's what keeps a room comfortable in summer without it turning clammy.

62 cfmFresh air through the vent

With the vent open, Durastar publishes 62 cfm of outside air at high speed. Close it to keep all the heat or the cool air in the room.

0 °CRoom freeze protection

In an unoccupied room, Durastar provides automatic freeze protection at 32 °F (0 °C): the fan and the heater restart on their own.

Replacement

It fits the standard wall sleeve

Durastar designs this PTAC for the standard 42 × 16 in wall sleeve; the sleeve and grille are sold separately. Our estimator checks the ones in place before ordering.

42 × 16
inches, standard size
04 · Installation

What it needs on site

42 × 16 in sleeveIndustry-standard size
14 ¾ in sleeveDRPTACWS foldable sleeve
Dedicated 30 A circuitFor the 5.0 kW heater (NEMA 6-30P plug)
113.5 lbUnit weight

In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.

Complete spec sheetData and cited sources
Model
DRPTHP15Y32501A
Cooling capacity (208/230 V)
14,500 / 14,700 BTU/h
Heating capacity, heat pump (208/230 V)
13,200 / 13,500 BTU/h
Electric heater
5.0 kW (4,100 / 5,000 W at 208/230 V)
EER
10.6
COP (heat pump, 8 °C)
3.2
Current — cooling (208/230 V)
7.4 / 6.5 A
Current — heat-pump heating (208/230 V)
6.4 / 6 A
Power — cooling (208/230 V)
1,370 / 1,390 W
Power — heat pump (230 V)
1,170 W
Airflow (low/high)
330 / 416 cfm
Sound level (low/high)
52.5 / 53 dB(A)
Dehumidification
4.3 pints/h
Published cooling area
550 to 700 sq ft
Dimensions
42 × 21 × 16 in (W × D × H)
Net weight
113.5 lb
Refrigerant
R-32 · 31.7 oz
Heat pump → heater
below 40 °F (4 °C) outside
Power supply
208/230 V · 1 ph · 60 Hz
Spec sheet (French)
PDF
Spec sheet (English)
PDF

All values: Durastar PTAC/PTHP R-32 submittal, form V1.1_0324 (March 2024). Operating cost: cooling at 1,387 W for 200 h per summer; heating estimated for a typical 625 sq ft room (4,464 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.

05 · In the same family

The neighbouring models

Talk to an HVAC technician before you choose

We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.

Zéro dollar d'aide financière : le budget d'une chambre d'appoint se calcule autrement

Un établissement de santé de Châteauguay dont la chambre d'appoint a fait grimper la facture d'hiver veut d'abord savoir sur quoi il peut compter. La réponse tient en une ligne, et elle vaut mieux avant la soumission qu'après : aucun programme d'aide ne vise ce type d'appareil. La Thermopompe PTAC DURASTAR | 15 000 BTU 5 kW - R32 se choisit pour ce qu'elle fait dans le mur, pas pour une subvention qui n'existe pas.

Le 0 $ de la fiche, expliqué avant le reste

Les programmes d'aide visent des appareils inscrits sur une liste, où un monobloc traversant le mur ne figure pas : d'où le 0 $ de la fiche technique. Nous le disons tôt parce que cela change l'ordre des arguments, pas parce que cela disqualifie l'appareil. Ce qu'il apporte : une chambre traitée seule, aucune unité extérieure sur le terrain et aucune ligne frigorifique dans les corridors.

Les chiffres qui restent une fois l'aide écartée

  • Capacité nominale : 15 000 BTU/h, chauffage électrique de 5 kW
  • Réfrigérant : R-32
  • Alimentation : 220 V, sur circuit dédié
  • Niveau sonore intérieur : 52,5 et 53,0 dB(A)
  • Caisson : 42 x 21 x 16 po, modèle DRPTHP15Y32501A

DuraStar ne publie pas de certificat AHRI pour cet appareil ; ces valeurs sont celles de sa fiche technique. Aucune capacité de chauffage n'y est inscrite, alors nous n'en annonçons pas. Quand la chambre est bien isolée et la consigne modérée, la version 3,5 kW couvre le même plan.

Châteauguay, en établissement : accès au mur, dégagements et heures de travaux

L'accès au mur dans une chambre occupée

La coupe se fait à l'empreinte du caisson, 42 x 21 x 16 po, avec un linteau si un montant porteur est interrompu. Dans un établissement, l'accès se planifie avant la structure : heures convenues, chambre libérée, corridors protégés, poussière confinée, manchon mural posé et pourtour refermé le jour même. La grille extérieure vient au-dessus de la ligne de neige.

Les dégagements devant le caisson

Un monobloc souffle dans une seule direction. Le lit, un fauteuil de repos ou un paravent placés dans l'axe renvoient l'air là où personne ne le veut, et une reprise d'air obstruée fait tourner l'appareil plus longtemps. Nous fixons ces dégagements avec le plan d'aménagement réel de la chambre, pas avec un plan théorique.

Les gestes d'entretien en chambre occupée

  • Un délai de trois minutes au redémarrage protège le compresseur.
  • De la vapeur blanche à la grille en mode chauffage signale un dégivrage.
  • Le condensat quitte le caisson par le bas, côté extérieur.

Une odeur de brûlé, un disjoncteur qui saute, un code d'erreur récurrent ou de l'eau côté chambre commandent l'arrêt et un appel à notre service de réparation. Le filtre se nettoie aux deux semaines et un entretien CVAC annuel reprend serpentins, écoulement et raccords.

AirGreen, en établissement de santé

AirGreen est une entreprise familiale de Montréal, active depuis plus de quinze ans à Montréal, Laval, Longueuil, sur la Rive-Nord et la Rive-Sud, avec une assurance responsabilité de 5 000 000 $. Nos réalisations comprennent des chambres traitées une à une, hors des heures de soins.

Planifiez votre estimation gratuite pour la Thermopompe PTAC DURASTAR | 15 000 BTU 5 kW - R32. Nous confirmons par écrit qu'aucune aide ne s'applique, fixons les heures de travaux et validons les dégagements de la chambre.

Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.