A.C.R. Soft Copper Tube – 50 ft Coil

In stock

Soft copper tube in coils for running the refrigerant lines of a heat pump or air conditioner.

AirGreen codeAG-CU-00104

1/8 to 1-1/8 in10 outside diameters
50 ftper coil
Softbends on site
ACR copperRefrigerant piping
Diameter
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-CU-00104
MaterialCopper
TemperSoft (annealed), coiled
Length50 ft (15.2 m)
SizingOutside diameter
SoldPer coil

A.C.R. soft copper tube is the tube you uncoil to run the refrigerant lines of a heat pump or an air conditioner. Sold in a 50 ft coil, it is bent on site and follows the route between the indoor unit and the outdoor unit with a minimum of fittings.

Soft tube for running refrigerant lines

We use it for the liquid and suction lines of wall-mounted heat pumps, multi-zone systems and central heat pumps, to extend an existing line or to build a custom line that is then insulated. The ASTM B280 standard covers seamless copper tube for field connection and repair of air conditioning and refrigeration equipment.

Ten outside diameters

The coil is available in 1/8 in, 3/16 in, 1/4 in, 5/16 in, 3/8 in, 1/2 in, 5/8 in, 3/4 in, 7/8 in and 1-1/8 in. A.C.R. tube is designated by its actual outside diameter: a 5/8 in tube fits a 5/8 in fitting and matches a 5/8 in equipment port. The diameters to use are in the unit’s installation manual.

Bending and cutting without damaging the tube

  • Bend with a tube bender of the right diameter so you don’t crush or kink the tube.
  • Cut with a tube cutter, deburr, then seal the end of the coil to keep it clean and dry.
  • Connect by brazing under a light flow of dry nitrogen, or by flaring on units with flare connections.

Work on a refrigerant circuit is reserved for a qualified refrigeration technician.

Supplied and installed by AirGreen across Greater Montréal

Our refrigeration technicians run, braze and insulate the refrigerant lines on every installation in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For the availability of a diameter or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the diameter and the number of coils.

01 · What it is for

The basic tube behind every refrigerant line

A soft coil unrolls and bends along the route, with fewer fittings than rigid tube.

  • Liquid and suction lines of wall-mount, multi-zone and central heat pumps
  • Replacing or extending an existing line
  • Small sizes for refrigeration circuits and short connections
  • Custom lines, insulated afterwards with tubular insulation
Fewer jointsSoft tube follows the route: every fitting you skip is one less joint to braze and check.
Sized by outside diameterA 3/8 in tube measures 3/8 in outside, like the fittings and equipment ports it connects to.
ACR gradeTube meant for air conditioning and refrigeration circuits, not plumbing tube.
02 · Sizes

10 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

DiameterAirGreen code
1/8 inAG-CU-00101
3/16 inAG-CU-00102
1/4 inAG-CU-00103
5/16 inAG-CU-00104
3/8 inAG-CU-00105
1/2 inAG-CU-00106
5/8 inAG-CU-00107
3/4 inAG-CU-00108
7/8 inAG-CU-00109
1-1/8 inAG-CU-00110

Outside diameter of the tube, in inches. Every coil is 50 ft.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

TypeSeamless ACR copper tube, soft
MaterialCopper
Packaging50 ft (15.2 m) coil
Sizes1/8, 3/16, 1/4, 5/16, 3/8, 1/2, 5/8, 3/4, 7/8 and 1-1/8 in
SizingActual outside diameter
ConnectionBrazed or flared
AirGreen codeAG-CU-00104
04 · Before installing

What to know before installing

  • Take line sizes from the equipment installation manual, never by eye.
  • Bend with a bender sized for the tube so it does not kink.
  • Cut with a tube cutter, deburr, and close the end of the coil after each cut.
  • Work on a refrigerant circuit is reserved for a qualified refrigeration technician.
05 · Goes with

You may also need

Same category
Refrigerant piping
See all
06 · Questions

Frequently asked questions

Is the size inside or outside diameter?

Outside. ACR tube is designated by its actual outside diameter, unlike plumbing tube, which uses a nominal size.

How is it different from a pre-insulated line set?

This is a single bare tube that you insulate yourself. A line set already pairs the liquid and gas lines under insulation.

Can this tube be flared?

Yes, soft tube flares with a proper flaring tool. Larger sizes are usually brazed instead.

Can you install the piping?

Yes. Our technicians run, braze and insulate refrigerant lines on every heat pump installation in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Copper tube for clean refrigerant lines

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom