Réparation d’une thermopompe murale Fujitsu à Laval-des-Rapides
Job photo

A night service call for an R-410A refrigerant leak

At AirGreen , we often respond to urgent situations related to performance losses in Fujitsu wall-mounted heat pumps , especially in early spring, when systems switch from heating to cooling mode. This is exactly the case during this intervention in Laval-des-Rapides , where a customer contacted us in the evening: his unit was no longer producing heat and the outdoor compressor seemed to be running continuously without any tangible results.


Diagnosis: a slow leak in the refrigeration circuit

Upon arrival, we immediately noticed that the Fujitsu wall-mounted heat pump , installed on a side wall of the residence, was displaying abnormally low pressure. Using our electronic manifold , we connected our high and low pressure hoses and found that the R-410A refrigerant had almost completely escaped from the circuit.

The signs observed:

  • Warm indoor outlet air temperature despite heating mode being activated.

  • Irregular compressor noise.

  • Oil accumulation on a bend in the copper line, a typical sign of a microleak.

This slow loss, although minimal, was enough to drastically reduce the system's efficiency.


Steps of repair

1. Leak detection and repair

We injected a fluorescent tracer into the circuit, then used a UV lamp to pinpoint the leak. It was coming from a cracked solder joint on the suction line at the compressor outlet. After purging and isolating the circuit, we made a silver solder repair , then performed a leak test under nitrogen pressure at 350 psi for 30 minutes. No pressure loss was observed.

2. Deep vacuum draw

Once the leak was repaired, we connected our dual-stage vacuum pump , providing a vacuum down to -500 microns . This step is essential to remove all traces of moisture and air from the system, thus preventing the formation of acid in the compressor.

3. Recharge with R-410A refrigerant

We then proceeded to a complete recharge of the system following the manufacturer's nominal charge, i.e. 1.25 kg of R-410A, measured on an electronic scale. The operation was carried out with the greatest precision:

  • Low pressure: 115 psi

  • High pressure: 385 psi

  • Blowing temperature: 11°C in cold mode after stabilization

These values ​​confirmed a return to the original performance of the system.


Final checks and recommendations

After recharging, the Fujitsu heat pump resumed stable and quiet operation. The customer immediately noticed the difference: cooler air, normal power consumption, and an automatic compressor shutoff when the target temperature was reached.

We recommended to the client:

  • Have the refrigeration connections inspected every year , especially during seasonal transitions.

  • Keep the exterior base clean and clear , as debris and moisture can accelerate corrosion of copper tubing.

  • Plan for annual AirGreen preventive maintenance , which includes checking pressures, cleaning coils and measuring delta T.


A typical intervention of AirGreen rigor in Laval

This repair perfectly illustrates our technical expertise and our commitment to the sustainability of HVAC systems . At AirGreen, we always prioritize the most reliable and cost-effective solution for our customers.

Our teams serve all of Laval , including Chomedey, Vimont, Sainte-Rose and Fabreville , as well as the North Shore and the South Shore for all your repair, maintenance or installation needs for Fujitsu, Gree, Midea, Sharp, Trane or Zephyr wall-mounted heat pumps .

By choosing AirGreen, each client benefits from field expertise, advanced diagnostic tools and local service across Greater Montreal.


SEO keywords: Fujitsu wall-mounted heat pump repair Laval, R-410A recharge, HVAC maintenance Montreal, AirGreen service North Shore

You made it to the end.Share it with someone it could help.
Near you

More AirGreen jobs in the area

Other jobs, not the one described above.

Keep reading

Latest published jobs

AirGreen Climatisation & Chauffage

The same service at your place?

Cleaning, repair or maintenance: tell us about your unit and we schedule the visit.

  • RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
  • $5M liability insuranceOn every job
  • 15+ yearsFamily-owned, based in Montréal