Réparation d’une thermopompe murale Mitsubishi à Outremont
Reading time: 3'

Repair of a Mitsubishi wall-mounted heat pump in Outremont

A Mr. Slim heat pump in distress in a hard-to-reach corner

Recently, our AirGreen team was called to repair a Mitsubishi Mr. Slim wall-mounted heat pump in a charming duplex in Montreal's Outremont neighborhood. The outdoor unit, installed in a tight space between two brick walls, was experiencing poor heating performance and an abnormal noise when turned on . These symptoms, often overlooked by homeowners, can signal impending fan failure or a refrigerant pressure issue.

Diagnosis: A confined space and an overheating device

Upon our arrival, we noticed several challenges:

  • The unit was installed very close to the walls , limiting air circulation.

  • Debris and dust had accumulated on the condenser.

  • The outside fan was struggling to maintain the correct pressure.

Using our measuring instruments, we observed a slightly lower than normal refrigerant pressure , which indicated a microleak in the circuit . The compressor, which was overheating for a long time, was also at risk of damage.

Technical intervention: cleaning, detection and recharging

Our certified technicians proceeded in stages:

  1. Thorough cleaning of the condenser using a gentle jet and a specialized biodegradable product for aluminum surfaces.

  2. Nitrogen test to locate the leak. It came from a cracked solder joint on a copper junction, a common weak point in older installations.

  3. Repair of the solder and checking for leaks .

  4. Recharge of R410A refrigerant according to Mitsubishi specifications.

  5. Complete performance test with temperature measurement and differential pressure measurement.

Everything was carried out in compliance with environmental standards and safety procedures specific to our industry.

Result: efficiency restored and comfort restored

Once the heat pump was restarted, tests revealed:

  • Airflow restored to 100% .

  • Optimal thermal efficiency , with an interior/exterior temperature delta in line with Mitsubishi standards.

  • A reduction in fan noise , evidence of a newly balanced engine.

We also advised the customer to leave a minimum clearance of 30 cm around the unit to improve ventilation and extend the life of the compressor.

The importance of regular maintenance

Mitsubishi Mr. Slim wall-mounted heat pumps are renowned for their reliability, but they require annual maintenance to avoid this type of failure:

  • Cleaning the condenser and evaporator.

  • Checking the refrigerant charge.

  • Electrical and mechanical inspection of the motor and boards.

  • Automatic drainage and defrost control.

Regular maintenance by a qualified team like AirGreen not only ensures quiet and efficient operation , but also prevents costly repairs in the long run.

Our Mitsubishi expertise in Montreal and throughout the metropolitan area

At AirGreen , we are authorized specialists in Mitsubishi Electric systems . Whether for installation, diagnosis, or repair, our teams respond quickly in Montreal, Laval, Longueuil, the North Shore, and the South Shore . Every service call is handled with rigor, transparency, and a deep respect for our customers' comfort.

In the case of this intervention in Outremont, our client was able to regain immediate comfort , reduced energy consumption , and above all the peace of mind provided by a perfectly adjusted HVAC system.