Job sheet · Project

Installation of a GREE FREE MATCH R32 Heat Pump Double Zone - 2 Zones - 2 Heads in Saint-Vincent-de-Paul, Laval

AirGreen installs a GREE FREE MATCH R32 DoubleZone heat pump in Saint-Vincent-de-Paul: two comfort zones, wall-mounted outdoor unit, neat finish, and durable HVAC installation.

By AirGreen Climatisation & Chauffage Admin11 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
11 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a GREE FREE MATCH R32 Heat Pump Double Zone - 2 Zones - 2 Heads in Saint-Vincent-de-Paul, Laval
Installation of a GREE FREE MATCH R32 Heat Pump Double Zone - 2 Zones - 2 Heads in Saint-Vincent-de-Paul, Laval
The full story

The article, chapter by chapter

A DoubleZone installation in an urban environment, perfectly suited to the building

In the Saint-Vincent-de-Paul area in Laval, this installation of a GREE FREE MATCH R32 DoubleZone heat pump represents a typical project where the quality of on-site work makes all the difference. The client wanted to improve the comfort of two distinct zones in their home without multiplying outdoor units or overloading the facade. The chosen solution: a DoubleZone heat pump - 2 zones - 2 heads, capable of serving two indoor spaces from a single outdoor unit.

The photo clearly illustrates the reality of this type of project in an urban environment: brick facade, limited space, nearby window, concrete foundation, existing lines around the building, and the need to position the outdoor unit precisely. Here, the GREE outdoor unit was installed on sturdy wall mounts, above the lower level, to keep it clear, stable, and accessible for future maintenance.

This choice of wall installation is not just aesthetic. In Laval, as in Montreal, Longueuil, on the North Shore and on the South Shore, we often encounter buildings where the ground is not the ideal place to place an outdoor unit. Snow, yard constraints, narrow passages, side clearances, and the presence of windows can complicate installation. By mounting the unit on suitable supports, we reduce risks related to snow accumulation, protect the device from certain impacts, and facilitate drainage around the machine.

Why the GREE FREE MATCH R32 is well suited for a 2-zone setup

The GREE FREE MATCH R32 is a particularly interesting multi-zone solution when an owner wants to air condition and heat two spaces without installing two separate systems. With a single outdoor unit, it is possible to power two indoor heads, each controlled independently. This flexibility is valuable in houses, condos, plexes, and Laval apartments, where rooms do not always have the same needs.

One zone may be more exposed to the afternoon sun, while another may require more stable heating in the evening. A living room, bedroom, office, or open area do not respond the same way to temperature variations. A DoubleZone heat pump therefore allows better daily comfort adaptation, instead of forcing a single unit to meet all the residence’s demands.

The refrigerant R32, visible on the outdoor unit’s label, confirms that we are dealing with a recent generation of HVAC systems. This refrigerant is used in several modern devices for its good thermal performance and reduced environmental impact compared to older refrigerants. For the client, this means an installation aligned with current market standards for the heat pump.

The exact BTU capacity of a FREE MATCH system always depends on the final combination between the outdoor unit and the two indoor units. In this type of project, we validate the configuration according to several factors: room size, insulation, window orientation, ceiling height, zone usage, pipe length, and available electrical capacity. This validation is essential to avoid a system that is too weak, too strong, or poorly balanced.

An outdoor unit fixed on brick: precision, solidity, and building protection

Installation on a brick facade requires a rigorous method. It is not enough to just fix two brackets to the wall. You must consider the type of masonry, the condition of the facing, the installation height, possible vibrations, and the weight of the unit.

On this project in Saint-Vincent-de-Paul, our team chose a position that respects three priorities:

  • keep the outdoor unit well cleared to ensure good air circulation;
  • protect the facade and building structure;
  • maintain reasonable access for HVAC maintenance and future inspections.

The wall mounts visible in the photo are installed to distribute the load properly. The unit is stable, upright, and securely anchored. The dampers and fasteners help limit vibration transmission to the building, an important point when the unit is fixed near a window or an occupied wall.

We also paid attention to the immediate environment of the unit. The outdoor unit is located under a window but with enough clearance for its operation. The front fan must be able to expel air without obstruction. A lack of clearance can reduce efficiency, increase noise, and force the compressor to work longer. In a professional HVAC installation, these details are checked before commissioning.

Management of conduits, electricity, and exterior aesthetics

One of the challenges of this installation was integrating the refrigerant lines and electrical connection on a facade already occupied by several elements. You can see the presence of wires, conduits, and an architecture typical of older urban buildings. In this context, work must be done neatly to avoid a cluttered result.

Our team organized the conduit routing in a functional way while maintaining a clean appearance. The goal was to connect the two indoor zones without creating an unnecessarily complex path. Every bend, every length of piping, and every penetration point in the building must be carefully considered.

The outdoor electrical box, visible near the unit, is also important. A heat pump must be powered according to the manufacturer's requirements and the standards applicable in Quebec. The circuit breaker, wiring, disconnect switch, and protections must match the installed machine. An installation can look good visually, but it is only complete if the electrical aspect is safe, compliant, and durable.

At AirGreen, we always emphasize this point: a multi-zone system is not just a machine plugged into the wall. It is a complete set that includes model selection, route planning, refrigerant connections, electrical supply, drainage, pressure tests, vacuuming, and operational testing.

The role of vacuuming and tests before startup

For a GREE FREE MATCH R32 DoubleZone, the quality of the refrigerant connections is crucial. A small mistake can cause performance loss, a leak, or premature compressor wear. That’s why our team follows a precise work sequence.

Before startup, we specifically perform:

  • inspecting the connections;
  • checking for leaks;
  • complete vacuuming of the lines;
  • checking pressure stability;
  • validating the operation of the two zones;
  • adjusting the basic settings;
  • explaining the controls to the customer.

Vacuuming removes air and moisture from the refrigerant circuit. This step is not visible in a photo, but it is one of the most important for the system's longevity. A HVAC installation that neglects this procedure may seem fine at first, then develop problems a few months or seasons later.

Two indoor heads for better distributed comfort

Even though the photo highlights the outdoor unit, the core of the project remains the management of two indoor zones. The DoubleZone heat pump allows the customer to adjust each head according to the room's use. This independence makes comfort much more precise.

In a residence in Saint-Vincent-de-Paul, it is common to have rooms with different thermal behaviors. Brick buildings can retain heat, large windows can amplify solar gains, and some closed rooms can remain colder in winter or warmer in summer. A two-head configuration helps balance these differences.

The customer thus obtains:

  • a more stable temperature in both spaces;
  • better usage efficiency;
  • less dependence on a single air outlet;
  • a reduction of zones that are too hot or too cold;
  • more flexible management according to life schedules.

For owners comparing a single zone and a DoubleZone, this point is often decisive. A single head can work well for an open area, but when two spaces are separated, a DoubleZone heat pump often makes more sense.

What this project in Saint-Vincent-de-Paul teaches Laval homeowners

This project shows that a successful installation depends as much on the chosen model as on how it is integrated into the building. A GREE FREE MATCH R32 can offer excellent comfort, but only if the configuration, clearances, connections, and commissioning are well executed.

Mistakes to avoid with a DoubleZone heat pump

The first mistake is choosing capacity based only on a quick estimate. Two rooms of the same size can have different needs depending on sunlight, insulation, ceiling height, and daily use. At AirGreen, we prefer to verify the building’s reality before recommending a configuration.

The second mistake is neglecting the outdoor location. On this installation in Laval, the wall position was carefully chosen. A unit installed too low can be exposed to snow. A unit too close to an obstacle may lack airflow. A poorly fixed unit can transmit vibrations. Every detail influences the final comfort.

The third mistake is underestimating HVAC maintenance. Even a modern system must be cleaned, inspected, and maintained. The filters of indoor units must be cleaned regularly. The outdoor unit must remain clear. The drains must stay functional. A good installation makes these tasks easier rather than more complicated.

Subsidies and eligibility: an essential check

Several customers contact us about a heat pump considering the available subsidies. This is an excellent approach, but eligibility should never be assumed without verification. For a GREE FREE MATCH R32, the criteria may depend on the exact combination of units, the applicable AHRI number, energy efficiency, and the program rules in effect at the time of installation.

At AirGreen, we assist clients with this verification before project confirmation. We clearly indicate the necessary information to keep, including the invoice, installed models, and relevant technical documents. This rigor prevents misunderstandings and allows the client to make an informed decision.

Local expertise for Montreal, Laval, Longueuil, North Shore, and South Shore

Our teams work every week in very varied contexts: single-family homes in Laval, condos in Montreal, multiplexes in Longueuil, residences on the North Shore, and residential projects on the South Shore. This diversity allows us to anticipate constraints before they become problems.

In Saint-Vincent-de-Paul, the main challenge was the clean integration of a multi-zone outdoor unit on a brick facade, in a narrow and already busy environment. The result is a stable, accessible installation, well positioned and consistent with the building.

This is exactly what we look for in every project: an HVAC installation that works efficiently, respects the structure, remains aesthetic, and facilitates daily use. A well-installed GREE FREE MATCH R32 DoubleZone heat pump can transform the comfort of a residence, but the difference lies in the details: anchoring, clearance, piping, drainage, electricity, vacuuming, and final inspection.

For owners in Laval considering a two-zone solution, this project shows that it is possible to achieve a clean result even in a limited outdoor space. With serious planning and an experienced team, a DoubleZone heat pump becomes a sustainable, efficient solution well suited to the realities of buildings in the region.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment