SENVILLE
SENVILLE LETO and FUJITSU AIRSTAGE ORION XLTH wall heat pumps: two 12,000 BTU units compared for the South Shore
The SENVILLE LETO and the FUJITSU AIRSTAGE ORION XLTH, number by number
The original article asked whether a budget SENVILLE wall heat pump performs well on the South Shore, and set it against the FUJITSU AIRSTAGE KZAH R-32, now sold as the ORION XLTH. Here are both, at 12,000 BTU, with what their AHRI certificates, the NEEP database and the manufacturers' documents publish. The purchase price is on each product page; this page looks at what comes after.
SENVILLE
FUJITSU AIRSTAGE
ORION XLTH 12,000 BTU (KZAH)
Indoor ASUH12KZAS · outdoor AOUH12KZAH1 · AHRI 214888802 · NEEP 392122 See the product pageWhat sets them apart, in three points
- WinterHSPF2 Region V of 7.0 for the LETO and 10.1 for the ORION XLTH: about $437 and $303 of electricity per winter for the same zone (AirGreen estimate, heating around the clock, Rate D average price, taxes included).
- Extreme coldThe LETO heats down to −15 °C according to SENVILLE, its last certified point. The ORION XLTH is certified down to −26.1 °C (12,200 BTU/h) and FUJITSU AIRSTAGE states that no device shuts it off at lower temperatures.
- On the wall31.57 in wide for the LETO, 38 9/16 in for the ORION XLTH. The LETO is controlled through Alexa according to SENVILLE; the ORION XLTH has Wi-Fi and the AIRSTAGE Mobile app.
What the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
The gap comes from two numbers on the certificate: HSPF2 Region V (7.0 for the LETO, 10.1 for the ORION XLTH) in winter and SEER2 (21.3 and 30.5) in summer. Each unit's purchase price is on its product page; this page does not compare prices.
Bring the thermometer down: what each manufacturer publishes, degree by degree
Longueuil, Brossard or Saint-Hubert: South Shore winters regularly drop below −15 °C, and Montréal's design temperature is −23.1 °C. Choose a temperature. Each card shows the maximum heating capacity published at that temperature, or the gap between the two published values on either side of it, and says when you leave the range the manufacturer states.
Estimated need: the zone from the “Cost” section (12,000 BTU/h at −23.1 °C), proportional to the gap between 18 °C and outdoors, as in AirGreen method v1.1. Solid bar: value published at this temperature; dotted bar: gap between two published values, with no interpolation; dotted outline: last published value, at a milder temperature.
Below −15 °C: every published point, and what the manufacturers say beyond it
NEEP certifies the LETO down to −15 °C, its last point, which is also the heating limit SENVILLE states. The ORION XLTH is certified down to −26.1 °C, with a design-manual point at −20.6 °C and a brochure saying no device shuts it off at lower temperatures.
Blue hatched area: below −15 °C, outside the heating range stated for the LETO. Red hatched area: below −26.1 °C, the ORION XLTH's last certified point. Percentages from FUJITSU AIRSTAGE brochure FG8153C (rev. 4/2025), 12KZAH1 column; dark tick: 100%. SENVILLE does not publish an equivalent percentage for the LETO.
What each manufacturer writes, feature by feature
A feature missing from a document is not necessarily missing from the unit: the document consulted does not mention it. Each card says who writes it.
LETOSENVILLE names control through Alexa, by voice or with the Alexa app; the word Wi-Fi does not appear in the sheet consulted.
ORION XLTHWi-Fi, AIRSTAGE Mobile app.
senville.ca, SENL-12CD/220 sheet; brochure FG8153CLETOHeating stated down to −15 °C; nothing is published below.
ORION XLTHHeating stated down to −26 °C, with no automatic shutoff; capacity not stated below −26 °C.
senville.ca; brochure FG8153CLETO150 W, on in heating mode.
ORION XLTH150 W, based on temperature and mode.
NEEP records 385692 and 392122LETONot stated by the manufacturer in the sheet consulted.
ORION XLTH“Minimum Heat” mode named in the brochure.
senville.ca; brochure FG8153CLETONot stated by the manufacturer in the sheet consulted.
ORION XLTHNamed in the brochure.
senville.ca; brochure FG8153CLETOLow, Medium, High and Turbo speeds published; dehumidification of 1.5 L/h.
ORION XLTHEconomy, energy saving and occupancy sensor named in the brochure.
senville.ca; brochure FG8153CIndoor unit sound, speed by speed
Indoor unit
Values published by each manufacturer, from the lowest speed to the highest.
How to read these numbers. dB(A) is a logarithmic scale: a few more decibels are clearly audible. Each point is a published fan speed; lower is quieter.
Why the gap is not exact. Neither SENVILLE nor FUJITSU AIRSTAGE states, in the documents consulted, the measuring distance or method: two numbers taken under different conditions do not compare one for one.
Measurements taken by each manufacturer with its own method; read them as an order of magnitude for each unit, not as an exact gap between the two.
On your wall, and outside: the published sizes
The indoor units, at the same scale


SENVILLE LETO

FUJITSU AIRSTAGE ORION XLTH

Outdoor units drawn to scale from the published dimensions (diagram, same proportions for both). A photo of each outdoor unit is on its product card, above.
| Installation | SENVILLE LETO | FUJITSU AIRSTAGE ORION XLTH |
|---|---|---|
| Maximum piping length | Not published by the manufacturersenville.ca SENL-12CD/220 sheet consulted | 82 ft (25 m)Submittal 12KZAH1 |
| Pre-charged length | 25 ftsenville.ca (the same sheet also describes a 16 ft kit) | 49 ftSubmittal 12KZAH1 |
| Maximum height difference | Not published by the manufacturersenville.ca SENL-12CD/220 sheet consulted | 66 ftSubmittal 12KZAH1 |
| Liquid – gas diameters | Not published by the manufacturersenville.ca SENL-12CD/220 sheet consulted | 1/4 – 3/8 inSubmittal 12KZAH1 |
| Indoor unit W × H × D, weight | 31.57 × 11.69 × 7.44 in, 19.4 lb | 38 9/16 × 11 × 9 7/16 in, 28 lb |
| Outdoor unit W × H × D, weight | 30.12 × 21.85 × 11.93 in, 59.08 lb | 31 7/16 × 24 7/8 × 11 7/16 in, 86 lb |
| Electrical protection | MCA 13 A, max. fuse 15 Asenville.ca | MCA 14.4 A, max. breaker 15 ADesign manual DR_AS233ES_02, electrical section |
| Dehumidification | 1.5 L/h | 1.9 L/h |
| Stated heating / cooling range | Heating down to −15 °C; cooling range not published in the sheet consulted | −26 to 24 °C / −10 to 50 °C |
| Outdoor unit sound | 54 dBsenville.ca, method not stated | 47 dB(A)Brochure FG8153C; 49 in cooling and 47 in heating per the submittal (anechoic chamber) |
What people ask us about these two wall units
Why compare the LETO with the ORION XLTH?
The original article compared the SENVILLE LETO with the FUJITSU AIRSTAGE KZAH R-32 and a Goodman. The KZAH is FUJITSU AIRSTAGE's ORION XLTH (same model numbers ASUH12KZAS and AOUH12KZAH1). The Goodman wall units offered on our site use R-410A; our comparison pages stick to the newer R-32 and R-454B refrigerants, hence a head-to-head of two.
Why does the LETO have no figure below −15 °C?
Because −15 °C is both the coldest point on its NEEP record and the heating limit SENVILLE states for the LETO series. No document consulted gives a figure for its operation at lower temperatures. Below that temperature, plan another heat source for the zone.
Are these two models eligible for LogisVert?
The conditions are in Hydro-Québec's LogisVert participant guide, which can change. To help you sort it out: the NEEP record of the LETO 12,000 says it is not ENERGY STAR certified; the ORION XLTH record says ENERGY STAR and cold climate. Check Hydro-Québec's official list before buying; we do not quote any amount.
What is HSPF2 Region V?
It is the seasonal heating efficiency calculated for the coldest region in the AHRI 210/240 standard. The higher it is, the less the heat pump uses for the same heat. It is the value behind the cost calculation above: 7.0 for the LETO, 10.1 for the ORION XLTH.
What happened to the customer reviews in the original article?
This version sticks to certificates and manufacturer documents that anyone can check: NEEP records, the SENVILLE spec sheet, the FUJITSU AIRSTAGE brochure and submittal. The references are in the sources.
Does the LETO come in 115 V?
Yes, AirGreen also offers the LETO 12,000 in 115 V, under another certificate (AHRI 215735287). This page compares the 208/230 V version, SENL-12CD220.
Does AirGreen offer both?
Yes, both models are on AirGreen's site; the links to their product pages are at the beginning of this page.
The certificate values, line by line
| Certified value | SENVILLE LETO | FUJITSU AIRSTAGE ORION XLTH |
|---|---|---|
| Certification | ||
| AHRI certificate · NEEP record | 215735289 · 385692 | 214888802 · 392122 |
| Refrigerant | R-454B | R-32 |
| ENERGY STAR · cold climate | No · noNEEP record 385692 | Yes · yesNEEP record 392122 |
| Seasonal efficiency | ||
| SEER2 | 21.3 | 30.5 |
| EER2 | 10.8 | 16.0 |
| HSPF2 Region IV | 9.1 | 12.7 |
| HSPF2 Region V | 7.0 | 10.1 |
| Heating, BTU/h and COP | ||
| Capacity at 8.3 °C, min. / rated / max. | 3,500 / 12,000 / 13,400 | 3,500 / 16,000 / 23,600 |
| COP at 8.3 °C, min. / rated / max. | 3.11 / 3.17 / 2.91 | 5.13 / 4.64 / 3.07 |
| Capacity at −8.3 °C, min. / rated / max. | 1,100 / 9,300 / 9,300 | 2,200 / 10,000 / 18,700 |
| COP at −8.3 °C, min. / rated / max. | 1.07 / 2.39 / 2.39 | 3.39 / 3.45 / 2.44 |
| Capacity at −15 °C, min. / rated / max. | 700 / 8,000 / 8,000 | 1,950 / 16,600 / 16,600 |
| COP at −15 °C, min. / rated / max. | 0.76 / 1.91 / 1.91 | 3.36 / 2.16 / 2.16 |
| Coldest certified point | ||
| Test temperature | −15 °C (5 °F) | −26.1 °C (−15 °F) |
| Maximum capacity at this point | 8,000 BTU/h | 12,200 BTU/h |
| Maximum COP at this point | 1.91 | 1.81 |
| Cooling | ||
| Cooling at 35 °C, min. / rated / max. | 1,700 / 12,000 / 13,300 | 3,100 / 12,000 / 16,000 |
“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The coldest-point rows are not marked: the two units are not tested at the same temperature there.
Both are on AirGreen's site.
A question about the LETO or the ORION XLTH for your South Shore home? Call us or ask for an estimate visit.
Documents consulted
Data verified November 17, 2026. Certified values: AHRI certificates published by NEEP. Declared values: manufacturer documents, cited on each line.
SENVILLE, LETO, FUJITSU, AIRSTAGE and ORION are trademarks of their respective owners. Logos and images are used to identify the products. AirGreen is a retailer; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca and we will correct it.
Sources checked October 13, 2026
- Hydro-Québec, LogisVert participant guide (residential), version 1.10 of September 15, 2026: PDF guide
- LogisVert support: 1 833 396-1888 (Monday to Friday, 8 a.m. to 8 p.m.). Applications online only at logisvert.ca.
- No grant if Hydro-Québec or another government body has already funded the same equipment or work (guide, section 4.1). Ask Hydro-Québec to confirm any combination.
Amounts shown are estimates; only the responsible organizations confirm the assistance granted.
From reading to your home.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.
- RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
- Free on-site estimateAn advisor assesses your needs
- Quote within 24 hoursClear and detailed