LogisVert · openFacts checked October 13, 2026

SENVILLE LETO and FUJITSU AIRSTAGE ORION XLTH wall heat pumps: two 12,000 BTU units compared for the South Shore

Article published 11 min
$120per 1,000 BTU/h at −8 °C, ENERGY STAR cold climate
$50per 1,000 BTU/h at −8 °C, ENERGY STAR
9 monthsto apply after installation, online only

Estimate the LogisVert grant for a heat pump

Certification

Indicative estimate

—

    Amounts shown are estimates; only the responsible organizations confirm the assistance granted.

    Your application deadline

    Pick a date to see your deadline.

    Processing takes 10 to 12 weeks after a complete application; the grant arrives by mail.

    Comparison · Wall heat pump · 12,000 BTU

    The SENVILLE LETO and the FUJITSU AIRSTAGE ORION XLTH, number by number

    The original article asked whether a budget SENVILLE wall heat pump performs well on the South Shore, and set it against the FUJITSU AIRSTAGE KZAH R-32, now sold as the ORION XLTH. Here are both, at 12,000 BTU, with what their AHRI certificates, the NEEP database and the manufacturers' documents publish. The purchase price is on each product page; this page looks at what comes after.

    SEER2 (cooling)21.3and30.5
    HSPF2 Region V (heating)7.0and10.1
    Coldest certified point−15 °Cand−26.1 °C
    RefrigerantR-454BandR-32
    AirGreen product card of the SENVILLE LETO wall heat pump SENVILLE

    LETO 12,000 BTU, 208/230 V

    Indoor SENL-12CD220-ILL · outdoor SENL-12CD220-OL · AHRI 215735289 · NEEP 385692 See the product page
    AirGreen product card of the FUJITSU AIRSTAGE ORION XLTH wall heat pump FUJITSU AIRSTAGE

    ORION XLTH 12,000 BTU (KZAH)

    Indoor ASUH12KZAS · outdoor AOUH12KZAH1 · AHRI 214888802 · NEEP 392122 See the product page

    What sets them apart, in three points

    1. WinterHSPF2 Region V of 7.0 for the LETO and 10.1 for the ORION XLTH: about $437 and $303 of electricity per winter for the same zone (AirGreen estimate, heating around the clock, Rate D average price, taxes included).
    2. Extreme coldThe LETO heats down to −15 °C according to SENVILLE, its last certified point. The ORION XLTH is certified down to −26.1 °C (12,200 BTU/h) and FUJITSU AIRSTAGE states that no device shuts it off at lower temperatures.
    3. On the wall31.57 in wide for the LETO, 38 9/16 in for the ORION XLTH. The LETO is controlled through Alexa according to SENVILLE; the ORION XLTH has Wi-Fi and the AIRSTAGE Mobile app.
    Estimated operating cost

    What the electricity costs, in dollars, winter and summer

    AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

    How this amount is calculated
    1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a temperature setback.
    2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
    3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down once the room is at the right temperature.
    4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

    AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

    The gap comes from two numbers on the certificate: HSPF2 Region V (7.0 for the LETO, 10.1 for the ORION XLTH) in winter and SEER2 (21.3 and 30.5) in summer. Each unit's purchase price is on its product page; this page does not compare prices.

    The South Shore thermometer

    Bring the thermometer down: what each manufacturer publishes, degree by degree

    Longueuil, Brossard or Saint-Hubert: South Shore winters regularly drop below −15 °C, and Montréal's design temperature is −23.1 °C. Choose a temperature. Each card shows the maximum heating capacity published at that temperature, or the gap between the two published values on either side of it, and says when you leave the range the manufacturer states.

    NEEP certifiedper the manufacturerhatching: below the stated range or no published figure
    −15 °C

    Estimated need: the zone from the “Cost” section (12,000 BTU/h at −23.1 °C), proportional to the gap between 18 °C and outdoors, as in AirGreen method v1.1. Solid bar: value published at this temperature; dotted bar: gap between two published values, with no interpolation; dotted outline: last published value, at a milder temperature.

    Extreme cold

    Below −15 °C: every published point, and what the manufacturers say beyond it

    NEEP certifies the LETO down to −15 °C, its last point, which is also the heating limit SENVILLE states. The ORION XLTH is certified down to −26.1 °C, with a design-manual point at −20.6 °C and a brochure saying no device shuts it off at lower temperatures.

    138%of 12,000 BTU/h at −15 °C, ORION XLTH
    124%at −21 °C
    102%at −26 °C

    Blue hatched area: below −15 °C, outside the heating range stated for the LETO. Red hatched area: below −26.1 °C, the ORION XLTH's last certified point. Percentages from FUJITSU AIRSTAGE brochure FG8153C (rev. 4/2025), 12KZAH1 column; dark tick: 100%. SENVILLE does not publish an equivalent percentage for the LETO.

    Features

    What each manufacturer writes, feature by feature

    A feature missing from a document is not necessarily missing from the unit: the document consulted does not mention it. Each card says who writes it.

    Wi-Fi and app

    LETOSENVILLE names control through Alexa, by voice or with the Alexa app; the word Wi-Fi does not appear in the sheet consulted.

    ORION XLTHWi-Fi, AIRSTAGE Mobile app.

    senville.ca, SENL-12CD/220 sheet; brochure FG8153C
    Extreme-cold shutoff

    LETOHeating stated down to −15 °C; nothing is published below.

    ORION XLTHHeating stated down to −26 °C, with no automatic shutoff; capacity not stated below −26 °C.

    senville.ca; brochure FG8153C
    Heated base pan

    LETO150 W, on in heating mode.

    ORION XLTH150 W, based on temperature and mode.

    NEEP records 385692 and 392122
    Minimum heat (freeze protection)

    LETONot stated by the manufacturer in the sheet consulted.

    ORION XLTH“Minimum Heat” mode named in the brochure.

    senville.ca; brochure FG8153C
    Automatic restart

    LETONot stated by the manufacturer in the sheet consulted.

    ORION XLTHNamed in the brochure.

    senville.ca; brochure FG8153C
    Operating modes

    LETOLow, Medium, High and Turbo speeds published; dehumidification of 1.5 L/h.

    ORION XLTHEconomy, energy saving and occupancy sensor named in the brochure.

    senville.ca; brochure FG8153C
    Quiet

    Indoor unit sound, speed by speed

    Indoor unit

    Values published by each manufacturer, from the lowest speed to the highest.

    dB

    How to read these numbers. dB(A) is a logarithmic scale: a few more decibels are clearly audible. Each point is a published fan speed; lower is quieter.

    Why the gap is not exact. Neither SENVILLE nor FUJITSU AIRSTAGE states, in the documents consulted, the measuring distance or method: two numbers taken under different conditions do not compare one for one.

    Measurements taken by each manufacturer with its own method; read them as an order of magnitude for each unit, not as an exact gap between the two.

    Installation

    On your wall, and outside: the published sizes

    The indoor units, at the same scale

    SENVILLE LETO31.57 in wide
    SENVILLE LETO indoor unit, to scale
    31.57 in · 80.2 cm
    FUJITSU AIRSTAGE ORION XLTH38 9/16 in wide
    FUJITSU AIRSTAGE ORION XLTH indoor unit, to scale
    38 9/16 in · 97.9 cm
    40 in

    SENVILLE LETO

    FUJITSU AIRSTAGE ORION XLTH

    0 in48 in

    Outdoor units drawn to scale from the published dimensions (diagram, same proportions for both). A photo of each outdoor unit is on its product card, above.

    InstallationSENVILLE LETOFUJITSU AIRSTAGE ORION XLTH
    Maximum piping lengthNot published by the manufacturersenville.ca SENL-12CD/220 sheet consulted82 ft (25 m)Submittal 12KZAH1
    Pre-charged length25 ftsenville.ca (the same sheet also describes a 16 ft kit)49 ftSubmittal 12KZAH1
    Maximum height differenceNot published by the manufacturersenville.ca SENL-12CD/220 sheet consulted66 ftSubmittal 12KZAH1
    Liquid – gas diametersNot published by the manufacturersenville.ca SENL-12CD/220 sheet consulted1/4 – 3/8 inSubmittal 12KZAH1
    Indoor unit W × H × D, weight31.57 × 11.69 × 7.44 in, 19.4 lb38 9/16 × 11 × 9 7/16 in, 28 lb
    Outdoor unit W × H × D, weight30.12 × 21.85 × 11.93 in, 59.08 lb31 7/16 × 24 7/8 × 11 7/16 in, 86 lb
    Electrical protectionMCA 13 A, max. fuse 15 Asenville.caMCA 14.4 A, max. breaker 15 ADesign manual DR_AS233ES_02, electrical section
    Dehumidification1.5 L/h1.9 L/h
    Stated heating / cooling rangeHeating down to −15 °C; cooling range not published in the sheet consulted−26 to 24 °C / −10 to 50 °C
    Outdoor unit sound54 dBsenville.ca, method not stated47 dB(A)Brochure FG8153C; 49 in cooling and 47 in heating per the submittal (anechoic chamber)
    Questions

    What people ask us about these two wall units

    Why compare the LETO with the ORION XLTH?

    The original article compared the SENVILLE LETO with the FUJITSU AIRSTAGE KZAH R-32 and a Goodman. The KZAH is FUJITSU AIRSTAGE's ORION XLTH (same model numbers ASUH12KZAS and AOUH12KZAH1). The Goodman wall units offered on our site use R-410A; our comparison pages stick to the newer R-32 and R-454B refrigerants, hence a head-to-head of two.

    Why does the LETO have no figure below −15 °C?

    Because −15 °C is both the coldest point on its NEEP record and the heating limit SENVILLE states for the LETO series. No document consulted gives a figure for its operation at lower temperatures. Below that temperature, plan another heat source for the zone.

    Are these two models eligible for LogisVert?

    The conditions are in Hydro-Québec's LogisVert participant guide, which can change. To help you sort it out: the NEEP record of the LETO 12,000 says it is not ENERGY STAR certified; the ORION XLTH record says ENERGY STAR and cold climate. Check Hydro-Québec's official list before buying; we do not quote any amount.

    What is HSPF2 Region V?

    It is the seasonal heating efficiency calculated for the coldest region in the AHRI 210/240 standard. The higher it is, the less the heat pump uses for the same heat. It is the value behind the cost calculation above: 7.0 for the LETO, 10.1 for the ORION XLTH.

    What happened to the customer reviews in the original article?

    This version sticks to certificates and manufacturer documents that anyone can check: NEEP records, the SENVILLE spec sheet, the FUJITSU AIRSTAGE brochure and submittal. The references are in the sources.

    Does the LETO come in 115 V?

    Yes, AirGreen also offers the LETO 12,000 in 115 V, under another certificate (AHRI 215735287). This page compares the 208/230 V version, SENL-12CD220.

    Does AirGreen offer both?

    Yes, both models are on AirGreen's site; the links to their product pages are at the beginning of this page.

    Certified data

    The certificate values, line by line

    Certified valueSENVILLE LETOFUJITSU AIRSTAGE ORION XLTH
    Certification
    AHRI certificate · NEEP record215735289 · 385692214888802 · 392122
    RefrigerantR-454BR-32
    ENERGY STAR · cold climateNo · noNEEP record 385692Yes · yesNEEP record 392122
    Seasonal efficiency
    SEER221.330.5
    EER210.816.0
    HSPF2 Region IV9.112.7
    HSPF2 Region V7.010.1
    Heating, BTU/h and COP
    Capacity at 8.3 °C, min. / rated / max.3,500 / 12,000 / 13,4003,500 / 16,000 / 23,600
    COP at 8.3 °C, min. / rated / max.3.11 / 3.17 / 2.915.13 / 4.64 / 3.07
    Capacity at −8.3 °C, min. / rated / max.1,100 / 9,300 / 9,3002,200 / 10,000 / 18,700
    COP at −8.3 °C, min. / rated / max.1.07 / 2.39 / 2.393.39 / 3.45 / 2.44
    Capacity at −15 °C, min. / rated / max.700 / 8,000 / 8,0001,950 / 16,600 / 16,600
    COP at −15 °C, min. / rated / max.0.76 / 1.91 / 1.913.36 / 2.16 / 2.16
    Coldest certified point
    Test temperature−15 °C (5 °F)−26.1 °C (−15 °F)
    Maximum capacity at this point8,000 BTU/h12,200 BTU/h
    Maximum COP at this point1.911.81
    Cooling
    Cooling at 35 °C, min. / rated / max.1,700 / 12,000 / 13,3003,100 / 12,000 / 16,000

    “higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The coldest-point rows are not marked: the two units are not tested at the same temperature there.

    Both are on AirGreen's site.

    A question about the LETO or the ORION XLTH for your South Shore home? Call us or ask for an estimate visit.

    Sources

    Documents consulted

    NEEP, record 385692 (SENVILLE LETO)Cold-climate air source heat pump database, AHRI 215735289; consulted November 17, 2026.
    NEEP, record 392122 (FUJITSU AIRSTAGE ORION XLTH)AHRI 214888802, AIRSTAGE H-Series; consulted November 17, 2026.
    SENVILLE, SENL-12CD/220 sheet (LETO)senville.ca, technical specifications; consulted November 17, 2026.
    FUJITSU AIRSTAGE, brochure FG8153CORION XLTH series (KZAH), rev. 4/2025: ranges, 138/124/102% percentages, sound, features.
    FUJITSU AIRSTAGE, design manual DR_AS233ES_0212K capacity table, −5 °F: 14,920 BTU/h, 2.15 kW; −15 °F: 12,200 BTU/h, 1.97 kW; AOUH12 electrical section.
    FUJITSU AIRSTAGE, submittal 12KZAH1Version 20250409A: piping, outdoor sound, weights.
    Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5.
    NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days base 18 °C; design temperature −23.1 °C.
    You made it to the end.Share it with someone it could help.

    Sources checked October 13, 2026

    • Hydro-Québec, LogisVert participant guide (residential), version 1.10 of September 15, 2026: PDF guide
    • LogisVert support: 1 833 396-1888 (Monday to Friday, 8 a.m. to 8 p.m.). Applications online only at logisvert.ca.
    • No grant if Hydro-Québec or another government body has already funded the same equipment or work (guide, section 4.1). Ask Hydro-Québec to confirm any combination.

    Amounts shown are estimates; only the responsible organizations confirm the assistance granted.

    Leave a comment